Issues Resolved
API |
---|
Fixed a stability issue when accessing the date for a price list entry via the API. |
Data Output |
---|
Fixed an issue where the export data wizard was showing incorrect folder settings. |
Estimating |
---|
Fixed an issue with insulation area being calculated on sub-assembly parts. |
Interoperability |
---|
Fixed an issue where pending jobs are not deleted when CAMduct is run as a process. |
Manufacturing |
---|
Fixed an issue with slip and drive type connectors calculating incorrectly on ducts which are deeper than they are wide. |
Fixed an issue with Linear Nesting reporting the wrong material length with S&D connectors. |
Improved the interoperability of integral damper handle rotations on jobs exported from Revit. |
Fixed an issue where NCs were not being written via a process when Shear Nests were present. |
Fixed an issue on the ductboard plenum box pattern 1138 where the add hole option to specify on which side to position the hole was ignored. |
Fixed an issue that prevented linear ancillaries from being nested when contained within an ancillary kit. |
Other |
---|
Removed a redundant help widget from the item properties dialog. |
Fixed an issue with the Batched Custom Data Field print object which was not returning the expected values. |
Fixed an issue with the Length annotation on rectangular straights which was positioned incorrectly when using step down connectors. |
Pattern |
---|
Fixed an issue with pattern 48 where an offset branch is applied when the connector was incorrectly moved. |
Fixed an issue with pattern 1177 reporting an incorrect length. |
Fixed an issue with wrapped patterns displaying the connector snap in the wrong location. |
Fixed an issue with pattern 344 where invalid geometry was created when invalid dimensions were entered. |
Fixed an issue on straight duct pattern lengths, which were shorter than expected when configured with step down connectors. |
Changed the behavior of the connector straight adjust on patterns 7 and 417 so the development matches how the part looks. |
Fixed an issue with pattern 2 which was not allowing the vee notch angle to be changed from 170. |
Fixed an issue that caused costing units to be reverted to by quantity on parts that were imported from a txt file. |
Fixed an issue which prevented users from adding holes to ductboard patterns. |
Fixed an issue where Maximum Sheet size, Maximum Fold Length, and Minimum Fold Length options were not saved. |
Usability |
---|
Fixed an issue when duplicating materials which was not creating specification entries as requested. |