BIMDuctConnectorDefinition.SetShape Method
Parent Object:
BIMDuctConnectorDefinition
Description
Method that used to set the shape of the connector.
Syntax
BIMDuctConnectorDefinition.
SetShape(
Geometry As
ObjectCollection, [
ConnectorShape] As
BIMConnectorShapeEnum )
Parameters
Geometry |
ObjectCollection |
Input ObjectCollection that specifies the set of geometry used to define the connector position and shape. |
ConnectorShape |
BIMConnectorShapeEnum |
Input value that indicates the desired shape of the connector and how the geometry is to be evaluated. Valid values for the various types of connectors is shown below.
- Cable tray connectors: kRectangularShapeConnector or kUndefinedShapeConnector
- Conduit connectors: kCircularShapeConnector or kUndefinedShapeConnector
- Duct connectors: kRectangularShapeConnector, kCircularShapeConnector, kOvalShapeConnector or kUndefinedShapeConnector
- Electrical connectors: kUndefinedShapeConnector
- Pipe connectors: kCircularShapeConnector or kUndefinedShapeConnector
The input geometry for the various shapes can be the following:
- Circular shape
- Single circular face.
- Circular edge (it can be an arc)
- Rectangular shape
- Rectangular planar face.
- Four edges that define a rectangle as illustrated below.
- Slot shape
- Planar face that has a slot shape.
- Four edges that define a slot or oval shape, as illustrated below
This is an optional argument whose default value is 92673. |
Version
Introduced in version 2011