kAppearanceDesignTrackingProperties |
72 |
Appearance : String (VT_BSTR),Read Only, No UI, Need not be present, Appearance. |
kAuthorityDesignTrackingProperties |
43 |
Authority: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), If non-NULL, this signifies the authorization of this model. |
kCatalogWebLinkDesignTrackingProperties |
23 |
Catalog Web Link: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), If this is a Part from a Catalog, the Web address of the Catalog provider. |
kCategoriesDesignTrackingProperties |
56 |
Categories: String (VT_BSTR), Read Only, No UI, XML string providing the complete categorization of this model, along with the mappings of the Category Parameters to parameters within this Document. |
kCheckedByDesignTrackingProperties |
10 |
Checked By: String (VT_BSTR), Editable, UI on Status Page, Always present (default=empty string), Name of the person checking the Part. |
kCostCenterDesignTrackingProperties |
9 |
Cost Center: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), Cost Center responsible for the Project. |
kCostDesignTrackingProperties |
36 |
Cost: Currency (VT_CY), Editable, UI on Project Page, Always present (default=0), Cost of the Part. |
kCreationDateDesignTrackingProperties |
4 |
Creation Time: Date (VT_FILETIME), Read Only, UI on Project Page, Always present (default=data creation time), Time the data in this file was first created. Will remain the same after Save As or Copy operations. |
kDateCheckedDesignTrackingProperties |
11 |
Date Checked: Date (VT_FILETIME), Editable, UI on Status Page, Always present (default=0), Time on which the check was performed. |
kDateEngrApprovedDesignTrackingProperties |
13 |
Engr Date Approved: Date (VT_FILETIME), Editable, UI on Status Page, Always present (default=0), Time on which the approval of the Part's engineering was performed. |
kDateMfgApprovedDesignTrackingProperties |
35 |
Mfg Date Approved: Date (VT_FILETIME), Editable, UI on Project Page, Always present (default=0), Time on which the approval of the Part's manufacturing was performed. |
kDensityDesignTrackingProperties |
61 |
Density: Double (VT_R4), Read Only, No UI, Always present (default=-1), Density. |
kDescriptionDesignTrackingProperties |
29 |
Description: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), A user-defined description of the contents of this file. |
kDesignerDesignTrackingProperties |
41 |
Designer: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), If non-NULL, this is the name of the designer of this model. |
kDesignStatusDesignTrackingProperties |
40 |
Design Status: Long (VT_I4), Editable, UI on Status Page, Always present (default=0), 0=Not Set, 1=Work In Progress, 2=Pending, 3=Released. |
kDocSubTypeDesignTrackingProperties |
31 |
Document SubType: GUID (VT_CLSID), Read Only, No UI, Always present (default=Document's CLSID), Finer classification of this Document's type. Document's type can be retrived by calling ::ReadClassStg on the root-storage. |
kDocSubTypeNameDesignTrackingProperties |
32 |
Document SubType Name: String (VT_BSTR), Read Only, No UI, Always present (default=Document Type name), Display name of the finer classification of this Document's type. |
kDrawingDeferUpdateDesignTrackingProperties |
51 |
Defer Updates: Boolean (VT_BOOL), Editable, No UI, Always present?? (default=FALSE), Whether to suspend drawing updates that reflect changes in its referenced files. |
kEngineerDesignTrackingProperties |
42 |
Engineer: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), If non-NULL, this is the name of the engineer responsible for this model. |
kEngrApprovedByDesignTrackingProperties |
12 |
Engr Approved By: String (VT_BSTR), Editable, UI on Status Page, Always present (default=empty string), Name of the person approving the Part's engineering aspect. |
kExternalPropRevIdDesignTrackingProperties |
46 |
External Property Revision Id: GUID (VT_CLSID), Editable, No UI, Always present (default=initial GUID), GUID representing revision of external property sets (created by Third Parties). |
kFlatPatternDeferUpdateDesignTrackingProperties |
73 |
Flat Pattern Defer Update: Boolean (VT_BOOL), Editable, No UI, Always present?? (default=FALSE), Whether to suspend flat pattern updates. |
kFlatPatternExtentsAreaDesignTrackingProperties |
65 |
Flat Pattern Extents Area: Double (VT_R4), Read Only, No UI, Need not be present, Flat Pattern Extents Area. |
kFlatPatternExtentsLengthDesignTrackingProperties |
64 |
Flat Pattern Extents Length: Double (VT_R4), Read Only, No UI, Need not be present, Flat Pattern Extents Length. |
kFlatPatternExtentsWidthDesignTrackingProperties |
63 |
Flat Pattern Extents Width: Double (VT_R4), Read Only, No UI, Need not be present, Flat Pattern Extents Width. |
kLanguageDesignTrackingProperties |
50 |
Language: String (VT_BSTR), Read Only, No UI, Always present (default=empty string), If non-NULL, this is the language (specified in ISO 639-2 alpha-3) being used for displaying the user-friendly names of various pieces of data. |
kLastUpdatedWithDesignTrackingProperties |
67 |
Last Updated With: string (VT_BSTR),Read Only, UI on Detail Page, Always present (default=empty string), Last updated with which Inventor version. |
kManufacturerDesignTrackingProperties |
48 |
Manufacturer: String (VT_BSTR), Editable, No UI, Always present (default=Standard), This is the name of the manufacturer or supplier of this component. |
kMassDesignTrackingProperties |
58 |
Mass: Double (VT_R4), Read Only, No UI, Always present (default=-1), Mass. |
kMaterialDesignTrackingProperties |
20 |
Material: String (VT_BSTR), Read Only, UI in Material command, Always present (default=empty string), Name of the material used to build the Part. |
kMaterialIdentifierDesignTrackingProperties |
71 |
Material identifier : String (VT_BSTR),Read Only, No UI, Need not be present, Material Identifier. |
kMfgApprovedByDesignTrackingProperties |
34 |
Mfg Approved By: String (VT_BSTR), Editable, UI on Project Page, Need not be present, Name of the person approving the Part's manufacturing aspect. |
kParameterizedTemplateDesignTrackingProperties |
44 |
Parameterized Template: Bool (VT_BOOL), Read Only, No UI, Always present (default=FALSE), Whether this model is a parameterized template to produce other models. |
kPartIconDesignTrackingProperties |
28 |
Part Icon: Clipdata (VT_CLIPDATA), Read Only, No UI, Need not be present, Special icon to be used wherever appropriate (eg: Windows Explorer). |
kPartNumberDesignTrackingProperties |
5 |
Part Number: String (VT_BSTR), Editable, UI on Project Page, Always present (default=Filename), Tracking number assigned to the Part. |
kPartPropRevIdDesignTrackingProperties |
21 |
Part Property Revision Id: GUID (VT_CLSID), Editable, No UI, Always present (default=initial GUID), GUID representing revision of Part properties (SummaryInformation, DocumentSummaryInformation, UserDefinedProperties and DesignTrackingProperties). |
kProjectDesignTrackingProperties |
7 |
Project: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), Project for which this Part was generated. |
kProxyRefreshDateDesignTrackingProperties |
33 |
Proxy Refresh Date: Date (VT_FILETIME), Read Only, No UI, Always present (default=0), If this is Proxy file for a Part, the date/time when it was last refreshed with respect to the Part. |
kSheetMetalRuleDesignTrackingProperties |
66 |
Sheet Metal Rule : String (VT_BSTR),Read Only, No UI, Always present (default=empty string), Name of the Sheet Metal Rule used for Sheet Metal. |
kStandardDesignTrackingProperties |
37 |
Standard: String (VT_BSTR), Editable, No UI, Always present (default=empty string), If non-NULL, this is the specific standard that governs this component family. |
kStandardRevisionDesignTrackingProperties |
47 |
Standard Revision: String (VT_BSTR), Editable, No UI, Always present (default=empty string), Applicable when Standard is non-NULL. Indicates the particular version of the international standard being applied to the component. |
kStandardsOrganizationDesignTrackingProperties |
49 |
Standards Organization: String (VT_BSTR), Editable, No UI, Always present (default=Custom), This is the name of the organization that developed the specific standard to which this family might belong. |
kStockNumberDesignTrackingProperties |
55 |
Stock Number: String (VT_BSTR), Editable, UI on Project Page, Always present (default=Filename), Stock number assigned to the Part. |
kSurfaceAreaDesignTrackingProperties |
59 |
SurfaceArea: Double (VT_R4), Read Only, No UI, Always present (default=-1), SurfaceArea. |
kTemplateRowDesignTrackingProperties |
45 |
Template Row: GUID (VT_CLSID), Read Only, No UI, Need not be present, The row of parameters in the template from which this model was derived. |
kUserStatusDesignTrackingProperties |
17 |
User Status: String (VT_BSTR), Editable, UI on Status Page, Always present (default=empty string), Status of the Part. |
kValidMassPropsDesignTrackingProperties |
62 |
Valid MassProps: Long (VT_I4), Read Only, No UI, Always present (default=0), BitFlags indicating which MassProperties are Valid/Invalid. |
kVendorDesignTrackingProperties |
30 |
Vendor: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), Name of the vendor from which this Part is purchased. |
kVolumeDesignTrackingProperties |
60 |
Volume: Double (VT_R4), Read Only, No UI, Always present (default=-1), Volume. |
kWeldMaterialDesignTrackingProperties |