Share

PropertiesForDesignTrackingPropertiesEnum Enumerator

Description

Design Tracking Properties, InternalName: {32853F0F-3444-11d1-9E93-0060B03C1CA6}, Name: Design Tracking Properties - This Enum contains values that correspond with the ID's of the Property objects within the Design Tracking Properties PropertySet object.

Methods

Name Value Description
kAppearanceDesignTrackingProperties 72 Appearance : String (VT_BSTR),Read Only, No UI, Need not be present, Appearance.
kAuthorityDesignTrackingProperties 43 Authority: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), If non-NULL, this signifies the authorization of this model.
kCatalogWebLinkDesignTrackingProperties 23 Catalog Web Link: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), If this is a Part from a Catalog, the Web address of the Catalog provider.
kCategoriesDesignTrackingProperties 56 Categories: String (VT_BSTR), Read Only, No UI, XML string providing the complete categorization of this model, along with the mappings of the Category Parameters to parameters within this Document.
kCheckedByDesignTrackingProperties 10 Checked By: String (VT_BSTR), Editable, UI on Status Page, Always present (default=empty string), Name of the person checking the Part.
kCostCenterDesignTrackingProperties 9 Cost Center: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), Cost Center responsible for the Project.
kCostDesignTrackingProperties 36 Cost: Currency (VT_CY), Editable, UI on Project Page, Always present (default=0), Cost of the Part.
kCreationDateDesignTrackingProperties 4 Creation Time: Date (VT_FILETIME), Read Only, UI on Project Page, Always present (default=data creation time), Time the data in this file was first created. Will remain the same after Save As or Copy operations.
kDateCheckedDesignTrackingProperties 11 Date Checked: Date (VT_FILETIME), Editable, UI on Status Page, Always present (default=0), Time on which the check was performed.
kDateEngrApprovedDesignTrackingProperties 13 Engr Date Approved: Date (VT_FILETIME), Editable, UI on Status Page, Always present (default=0), Time on which the approval of the Part's engineering was performed.
kDateMfgApprovedDesignTrackingProperties 35 Mfg Date Approved: Date (VT_FILETIME), Editable, UI on Project Page, Always present (default=0), Time on which the approval of the Part's manufacturing was performed.
kDensityDesignTrackingProperties 61 Density: Double (VT_R4), Read Only, No UI, Always present (default=-1), Density.
kDescriptionDesignTrackingProperties 29 Description: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), A user-defined description of the contents of this file.
kDesignerDesignTrackingProperties 41 Designer: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), If non-NULL, this is the name of the designer of this model.
kDesignStatusDesignTrackingProperties 40 Design Status: Long (VT_I4), Editable, UI on Status Page, Always present (default=0), 0=Not Set, 1=Work In Progress, 2=Pending, 3=Released.
kDocSubTypeDesignTrackingProperties 31 Document SubType: GUID (VT_CLSID), Read Only, No UI, Always present (default=Document's CLSID), Finer classification of this Document's type. Document's type can be retrived by calling ::ReadClassStg on the root-storage.
kDocSubTypeNameDesignTrackingProperties 32 Document SubType Name: String (VT_BSTR), Read Only, No UI, Always present (default=Document Type name), Display name of the finer classification of this Document's type.
kDrawingDeferUpdateDesignTrackingProperties 51 Defer Updates: Boolean (VT_BOOL), Editable, No UI, Always present?? (default=FALSE), Whether to suspend drawing updates that reflect changes in its referenced files.
kEngineerDesignTrackingProperties 42 Engineer: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), If non-NULL, this is the name of the engineer responsible for this model.
kEngrApprovedByDesignTrackingProperties 12 Engr Approved By: String (VT_BSTR), Editable, UI on Status Page, Always present (default=empty string), Name of the person approving the Part's engineering aspect.
kExternalPropRevIdDesignTrackingProperties 46 External Property Revision Id: GUID (VT_CLSID), Editable, No UI, Always present (default=initial GUID), GUID representing revision of external property sets (created by Third Parties).
kFlatPatternDeferUpdateDesignTrackingProperties 73 Flat Pattern Defer Update: Boolean (VT_BOOL), Editable, No UI, Always present?? (default=FALSE), Whether to suspend flat pattern updates.
kFlatPatternExtentsAreaDesignTrackingProperties 65 Flat Pattern Extents Area: Double (VT_R4), Read Only, No UI, Need not be present, Flat Pattern Extents Area.
kFlatPatternExtentsLengthDesignTrackingProperties 64 Flat Pattern Extents Length: Double (VT_R4), Read Only, No UI, Need not be present, Flat Pattern Extents Length.
kFlatPatternExtentsWidthDesignTrackingProperties 63 Flat Pattern Extents Width: Double (VT_R4), Read Only, No UI, Need not be present, Flat Pattern Extents Width.
kLanguageDesignTrackingProperties 50 Language: String (VT_BSTR), Read Only, No UI, Always present (default=empty string), If non-NULL, this is the language (specified in ISO 639-2 alpha-3) being used for displaying the user-friendly names of various pieces of data.
kLastUpdatedWithDesignTrackingProperties 67 Last Updated With: string (VT_BSTR),Read Only, UI on Detail Page, Always present (default=empty string), Last updated with which Inventor version.
kManufacturerDesignTrackingProperties 48 Manufacturer: String (VT_BSTR), Editable, No UI, Always present (default=Standard), This is the name of the manufacturer or supplier of this component.
kMassDesignTrackingProperties 58 Mass: Double (VT_R4), Read Only, No UI, Always present (default=-1), Mass.
kMaterialDesignTrackingProperties 20 Material: String (VT_BSTR), Read Only, UI in Material command, Always present (default=empty string), Name of the material used to build the Part.
kMaterialIdentifierDesignTrackingProperties 71 Material identifier : String (VT_BSTR),Read Only, No UI, Need not be present, Material Identifier.
kMfgApprovedByDesignTrackingProperties 34 Mfg Approved By: String (VT_BSTR), Editable, UI on Project Page, Need not be present, Name of the person approving the Part's manufacturing aspect.
kParameterizedTemplateDesignTrackingProperties 44 Parameterized Template: Bool (VT_BOOL), Read Only, No UI, Always present (default=FALSE), Whether this model is a parameterized template to produce other models.
kPartIconDesignTrackingProperties 28 Part Icon: Clipdata (VT_CLIPDATA), Read Only, No UI, Need not be present, Special icon to be used wherever appropriate (eg: Windows Explorer).
kPartNumberDesignTrackingProperties 5 Part Number: String (VT_BSTR), Editable, UI on Project Page, Always present (default=Filename), Tracking number assigned to the Part.
kPartPropRevIdDesignTrackingProperties 21 Part Property Revision Id: GUID (VT_CLSID), Editable, No UI, Always present (default=initial GUID), GUID representing revision of Part properties (SummaryInformation, DocumentSummaryInformation, UserDefinedProperties and DesignTrackingProperties).
kProjectDesignTrackingProperties 7 Project: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), Project for which this Part was generated.
kProxyRefreshDateDesignTrackingProperties 33 Proxy Refresh Date: Date (VT_FILETIME), Read Only, No UI, Always present (default=0), If this is Proxy file for a Part, the date/time when it was last refreshed with respect to the Part.
kSheetMetalRuleDesignTrackingProperties 66 Sheet Metal Rule : String (VT_BSTR),Read Only, No UI, Always present (default=empty string), Name of the Sheet Metal Rule used for Sheet Metal.
kStandardDesignTrackingProperties 37 Standard: String (VT_BSTR), Editable, No UI, Always present (default=empty string), If non-NULL, this is the specific standard that governs this component family.
kStandardRevisionDesignTrackingProperties 47 Standard Revision: String (VT_BSTR), Editable, No UI, Always present (default=empty string), Applicable when Standard is non-NULL. Indicates the particular version of the international standard being applied to the component.
kStandardsOrganizationDesignTrackingProperties 49 Standards Organization: String (VT_BSTR), Editable, No UI, Always present (default=Custom), This is the name of the organization that developed the specific standard to which this family might belong.
kStockNumberDesignTrackingProperties 55 Stock Number: String (VT_BSTR), Editable, UI on Project Page, Always present (default=Filename), Stock number assigned to the Part.
kSurfaceAreaDesignTrackingProperties 59 SurfaceArea: Double (VT_R4), Read Only, No UI, Always present (default=-1), SurfaceArea.
kTemplateRowDesignTrackingProperties 45 Template Row: GUID (VT_CLSID), Read Only, No UI, Need not be present, The row of parameters in the template from which this model was derived.
kUserStatusDesignTrackingProperties 17 User Status: String (VT_BSTR), Editable, UI on Status Page, Always present (default=empty string), Status of the Part.
kValidMassPropsDesignTrackingProperties 62 Valid MassProps: Long (VT_I4), Read Only, No UI, Always present (default=0), BitFlags indicating which MassProperties are Valid/Invalid.
kVendorDesignTrackingProperties 30 Vendor: String (VT_BSTR), Editable, UI on Project Page, Always present (default=empty string), Name of the vendor from which this Part is purchased.
kVolumeDesignTrackingProperties 60 Volume: Double (VT_R4), Read Only, No UI, Always present (default=-1), Volume.
kWeldMaterialDesignTrackingProperties 57 Weld Material: String (VT_BSTR), Read Only, No UI, Always present (default=empty string), Name of the material used for Weld Beads.

Version

Introduced in version 4

Was this information helpful?