This topic lists network validation messages displayed in the Output window when the network is validated.

Messages related to Real Time Control are listed in the RTC Validation Messages topic.

Key to Messages

Left Column

The error message number is used internally by InfoWorks ICM. This number is unique, and may be useful when contacting our Support team.

Centre Column

Name:

The error or warning message that is displayed.

Info:

Additional information about the error or warning, such as the name of the network object where the anomaly occurred

Cause:

Why the message has been displayed

Advice:

What, if anything, you need to do about it.

Right Column

Information only - no further action needed

Warning - action may be required

Error - action necessary

List of Validation Messages

The table below displays the list of validation messages that will be displayed in the Output Window. Click on the message text for further information.

E0005

RTC definition must not contain spaces

Info

Network object ID

Cause

The name of an RTC Table or Variable referenced in the RTC definition field of the sections editor for a bank or base linear structure contains spaces.

Advice

Review RTC definition values in sections editor.

E0006

RTC definition for breach must have a measurement type of Depth or Height above datum

Info

Network object ID

Cause

An RTC Table or Variable has been referenced in the RTC definition field of the sections editor for a bank or base linear structure, but the Output measurement field (for a Table) or Measurement field (for a Variable) of the RTC definition is not set to Depth or Height above datum.

See Modelling Breaches in Banks and Linear Structures.

Advice

Set measurement field of RTC definition to either Depth or Height above datum.

E0150

Bank array has at least one vertex with undefined level

Info

River Reach / Inline Bank ID

Cause

The section data of a River Reach bank or Inline Bank object has one or more vertices with a missing Bank level value.

Advice

Ensure banks have Bank level values set at all points.

E2001

The network contains no nodes or links or 2D zones

Info

-

Cause

There are no node or link objects, or 2D zone objects present in the network.

Simulations cannot be run if none of these objects exist.

Advice

Add node, link and/or 2D zone objects to the network.

E2002

Number of 2d elements <number of elements> exceeds the licence limit <licence limit>

Info

-

Cause

The number of 2D elements in the network exceeds the number of elements that are included in the InfoWorks ICM licence.

Advice

Either reduce the number of 2D elements in the network or increase the element limit included in your licence.

E2003

The number of nodes <number of nodes> exceeds the licence limit <licence limit>

Info

-

Cause

The number of nodes in the network exceeds the number of nodes that are included in the InfoWorks ICM licence.

Advice

Either reduce the number of nodes in the network or increase the node limit included your licence.

E2025

Node is not connected to a link

Info

Node ID

Cause

A node whose Node type is set to Connect 2D is not connected to a link. A Connect 2D node must be connected to a conduit whose Conduit type is set to either Linear Drainage (2D) or Conduit (2D).

Advice

Ensure that the Connect 2D node is connected to a conduit whose type is set to either Linear Drainage (2D) or Conduit (2D). Alternatively, change the Node type setting to another type of node.

E2026

Manhole floor above manhole roof

Info

Node ID

Cause

Applicable to nodes whose Type is set to Manhole.

Chamber floor value > Chamber roof value.

Advice

Check the manhole parameters of the reported node.

E2026

Not in head discharge table

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Manhole and Flood type is set to Gully or Inlet.

Head discharge table associated with the node has not been defined.

Advice

Define new Head Discharge Table, or select an existing table.

E2027

Flood depth 2 not above flood depth 1

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Manhole and whose Flood type is either Storage or Gully where no Storage array has been defined for the gully.

Flood depth 1 value > Flood depth 2 value.

Advice

Check the manhole parameters of the reported node.

E2028

Not greater than 0.0

Info

Node ID

Cause

Applicable to nodes of whose Type is set to Storage or Manhole and whose Flood type is set to Gully.

Applicable to rows in the Level/Plan Area Storage Grid except for first and last row:

Plan Area value in the Level / Plan Storage Grid of the node <= 0

Advice

Check Level / Plan Area Storage Grid values.

E2033

Lowest storage level is below chamber floor

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Manhole and Flood type is set to Gully.

The lowest Level value in the Level / Plan Area Storage Grid of the gully node < Chamber floor level.

Advice

Check Level / Plan Area Storage Grid values. Set Relative to Ground option if required.

E2034

Lowest storage level is above ground

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Manhole and whose Flood Type is set to Gully.

The lowest Level value in the Level / Plan Area Storage Grid of the gully node > Ground level.

Advice

Check Level / Plan Area Storage Grid values.

E2035

Vegetation level is above the highest storage level

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Pond.

The Vegetation level value is outside of the range defined in the Level / Plan Area / Perimeter Grid of the Pond node.

Advice

Check Level / Plan Area / Perimeter Grid and Vegetation levels.

E2036

Vegetation level is below the lowest storage level

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Pond.

The Vegetation level value is outside of the range defined in the Level / Plan Area / Perimeter Grid of the Pond node.

Advice

Check Level / Plan Area / Perimeter Grid and Vegetation levels.

E2037

Liner level is below the lowest storage level

Info

Node ID

Cause

Applicable to nodes whose Type is set to Pond.

The Liner level value is outside of the range defined in the Level / Plan Area / Perimeter Grid of the Pond node.

Advice

Check Level / Plan Area / Perimeter Grid and Liner levels.

E2038

Vegetation level is below liner level

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Pond.

The Vegetation level value is below the Liner level of the Pond node.

Advice

Check Vegetation and Liner levels.

E2039

Highest pond storage level is above ground

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Pond.

The highest Level value in the Level / Plan Area / Perimeter Grid > Ground level value of the Pond node.

Advice

Check pond level values and ground level value.

E2040

More than one subcatchment drains to this pond

Info

Node ID

Cause

Applicable to nodes whose Node type is set Pond.

The pond node is the associated node ID for more than one subcatchment.

Advice

Check subcatchments are associated with the correct nodes.

E2046

No more than two overland links may be connected to this node

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Manhole and Flood type is set to Inlet.

There are more than two links of System type set to Overland connected to the node identified.

Advice

Check connectivity of inlet node.

E2047

One or more overland links must be attached to this inlet node

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Manhole and Flood type is set to Inlet for continuous and flow-efficiency inlets.

There are no links of System type set to Overland connected to the node identified.

Advice

Check connectivity of inlet node.

E2048

The highest storage level on an inlet cannot be equal to ground level

Info

Node ID

Cause

Applicable to nodes whose Node type is set to Manhole and whose Flood type is set to Inlet.

The highest Level value in the Storage Level / Plan Area grid is equal to the Ground Level value.

This is not allowed for inlet nodes, as storage type is assumed to be Lost in this case.

Advice

Add an extra Level entry in the Storage Level / Plan Area grid that is 1 mm above ground level.

E2050

Unconnected to outfall

Info

Conduit / Ancillary ID

Cause

The branch of the network that the link is connected in to does not lead to an Outfall Node.

Advice

Check the connectivity of the branch of the network containing the reported link.

E2051

Below attached node's lowest storage level

Info

Conduit ID

Cause

Applicable to conduits linked to Nodes of type Storage.

Upstream/Downstream Invert Level of downstream/upstream link < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check invert levels of connected links and Storage Node Level values.

E2051

Not in flow efficiency table

Info

Node ID

Cause

Applicable to nodes whose node type is set to Manhole and whose Flood type is set to Inlet.

The Flow Efficiency Table associated with node has not been defined.

Advice

Define new Flow Efficiency Table, or select an existing table.

E2052

Below attached node's chamber floor level

Info

Node ID

Cause

Applicable to conduits linked to Nodes of type Manhole.

US/DS Invert level of conduit < Chamber floor level of connected node.

Advice

Check invert levels of connected links and Node levels.

E2053

This field must be expressed as a percentage

Info

Node ID

Cause

Applicable to nodes of whose Node type is set to Manhole and whose Flood type is set to Inlet.

% Clogging value is less than 0 or greater than 100.

Advice

Redefine % Clogging value as a percentage.

E2060

Less than width/2

Info

Conduit ID

Cause

Applicable to conduits whose Shape ID is set to UTOP, OU, ARCH, OEGB and CNET.

Cross Section Height (m) < 0.5 x Width (m).

Advice

Check Cross Section parameters of reported conduit.

E2061

Less than width

Info

Conduit ID

Cause

Applicable to conduits whose Shape ID is set to OVAL.

Cross Section Height (m) < Width (m).

Advice

Check Cross Section parameters of reported conduit

E2062

Less than width

Info

Conduit ID

Cause

Applicable to conduits whose Shape ID is set to EGG.

Cross Section Height (m) < Width (m).

Advice

Check Cross Section parameters of reported conduit.

E2063

Less than height/2

Info

Conduit ID

Cause

Applicable to conduits whose Shape ID is set to EGG.

Cross Section Width (m) < 0.5 x Height (m).

Advice

Check Cross Section parameters of reported conduit

E2064

Less than width

Info

Conduit ID

Cause

Applicable to conduits whose Shape ID is set to EGG2.

Cross Section Height (m) < Width (m).

Advice

Check Cross Section parameters of reported conduit.

E2065

Less than (height-width)/2

Info

Conduit ID

Cause

Applicable to conduits whose Shape ID is set to EGG2.

Cross Section Width < 0.5 x (Height - Width).

Where Height and Width are in m.

Advice

Check Cross Section parameters of reported conduit.

E2066

Less than width

Info

Conduit ID

Cause

Applicable to conduits whose Shape ID is set to OEGN.

Cross Section Height (m) < 0.5 x Width (m).

Advice

Check Cross Section parameters of reported conduit.

E2067

Less than (height-width/2)/2

Info

Conduit ID

Cause

Applicable to conduits whose Shape ID is set to OEGN.

0.5 x Width < Height - (0.5 x Width).

Where Height and Width are in m.

Advice

Check Cross Section parameters of reported conduit.

E2069

Less than height-(width/2)

Info

Conduit ID

Cause

Applicable to conduits whose Shape ID is set to CNET.

0.5 x Width < Height - (0.5 x Width)

Where Height and Width are in m.

Advice

Check Cross Section parameters of reported conduit.

E2070

Not in shape set

Info

Conduit ID

Cause

The shape specified in the Shape ID field of the conduit does not exist.

Advice

Define new Shape or select existing Shape.

E2072

Less than height - width/2

Info

Conduit ID

Cause

Applicable to conduits whose Shape ID is set to OEGB.

Width < Height - (0.5 x Width)

Where Height and Width are in m.

Advice

Check Cross Section parameters of reported conduit.

E2072

Fill Material Conductivity is required for modelling Permeable Media solution-type conduits

Info

Conduit ID

Cause

Applicable to conduits whose Solution model is set to Permeable.

Fill material conductivity has not been defined.

Advice

Enter a value in the Fill material conductivity field.

E2073

The base flow depth exceeds the conduit height. Check simulation parameters

Info

Conduit ID

Cause

Sediment Depth + minimum base flow depth >= Conduit Height

1

Where minimum base flow depth is the greater of:

(conduit height - sediment depth) x Base Flow Factor

Where:

Base Flow Factor is defined in Simulation Parameters

If Gradient > Slope Where Base Flow is Doubled (defined in Simulation Parameters), minimum base flow depth = Equation 2 x 2

2

and

Minimum Base Flow Depth (defined in Simulation Parameters)

3

Advice

Check Simulation Parameters are as expected.

E2073

Porosity is required for modelling Permeable Media solution-type conduits

Info

Conduit ID

Cause

Applicable to conduits whose Solution model is set to Permeable.

Porosity has not been defined.

Advice

Enter a value in the Porosity field.

E2074

Hazen-Williams roughness can only be used on ForceMain pipes

Info

Conduit ID

Cause

Roughness Type field of conduit is set to HW, but Solution model field is not set to ForceMain.

Advice

Check Solution model and Roughness type fields are as expected.

E2075

Normal or high headlosses are not allowed for ForceMain Solution types

Info

Conduit ID

Cause

Solution Model field of conduit is set to ForceMain and Downstream headloss type or Upstream headloss type field is set to NORMAL or HIGH.

Headloss type must be set to FIXED or NONE when using the ForceMain solution model.

Advice

Check Solution Model and Headloss Type fields are as expected.

E2076

Below attached node's lowest storage level

Info

Flap Valve ID

Cause

Applicable to Flap Valves linked to Nodes of type Storage.

Upstream/Downstream Invert Level of downstream/upstream link < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check invert levels of connected links and Storage Node Level values.

E2076

Roughness value must be greater than zero

Info

Conduit ID

Cause

Top or Bottom Roughness value of conduit identified is less than zero.

Advice

Set roughness of conduit to value greater than zero.

E2077

Below attached node's chamber floor

Info

Flap Valve ID

Cause

Applicable to Flap Valve objects linked to Nodes of type Manhole.

Invert Level of Flap Valve < Chamber Floor Level of connected node

Advice

Check invert levels of connected links and Node Levels.

E2077

Springing height must be less than height

Info

Conduit ID

Cause

Conduit Shape ID is set to SPRUNGARCH and conduit Springing height is greater than conduit Height.

Advice

Check Springing height of conduit.

E2078

This 2D manhole/2D outfall is not contained within a 2D zone

Info

Node ID

Cause

2D node is not within a 2D Zone.

2D nodes are:

  • Nodes whose Node type is set to Manhole and Flood type is set to 2D or Gully 2D
  • Nodes whose Node typeis set to Outfall 2D

Advice

Add a 2D Zone that includes the 2D node within its boundary.

E2078

Height of arch above springing must be less than half of width

Info

Conduit ID

Cause

Conduit Shape ID is set to SPRUNGARCH and conduit Height - Springing height is greater than conduit Width/2.

Advice

Check Springing height of conduit.

E2079

This 2D manhole/2D outfall is not contained within a 2D zone mesh element

Info

Node ID

Cause

A 2D node is within a 2D Zone, but not within a mesh element.

2D nodes are:

  • Nodes whose Node type is set to Manhole and Flood type is set to 2D or Gully 2D
  • Nodes whose Node type is set to Outfall 2D

Advice

The 2D node may be within a void in the 2D mesh.

Check that the node location is as expected.

Check that the objects or file used to define voids are as expected.

E2080

FHWA is only valid as a US/DS headloss type if the US/DS node is a manhole FHWA is only valid as a US or DS headloss type if the conduit is closed FHWA is only valid if the solution model of the conduit is FULL

Info

Conduit ID

Cause

US/DS headloss type has been set to FHWA but the headloss type is not valid in the following conditions:

  • connected node has Node type set to type other than Manhole
  • conduit has Shape ID that defines an open pipe
  • conduit has Solution model set to type other than Full

Advice

Select a suitable headloss type for the conduit.

E2082

2D node with Chamber floor level >= Ground level

Info

Node ID

Cause

The node has Flood type of Gully 2D or 2D and the value in the Chamber floor level field is greater than or equal to the value in the Ground level field.

This can cause simulation convergence problems if the level in the 2D zone in which the node is located is lower than the node's chamber floor.

Advice

Check the level parameters of the node.

E2083

The minimum area including voids (Ag) is outside of the accepted range of 0 >= Ag <= W x L

Info

Node ID

Cause

The node has Inlet type of UPC Grate and the value in the Minimum area including voids field is greater than or equal to zero, or less than or equal to Grate width x Grate length.

Advice

Review the Inlet parameter field values.
E2084

The area of voids (Ah) is greater than the minimum area including voids (Ag)

Info

Node ID

Cause

The node has Inlet type of UPC Grate and the value in the Area of voids field is greater than the value in the Minimum area including voids field.

Advice

Review the Inlet parameter field values.
E2086

A value must be specified for this field when conduit headloss is FHWA

Info

Node ID

Cause

The Benching method field for the node has not been set and the conduit end that the node is connected to has headloss type set to FHWA.

Advice

Select a Benching method value for the node.

E2087

Flood type is lost; chamber floor height should not be greater than ground level

Info

Node ID

Cause

The node has Flood type of Lost and the value in the Chamber floor level field is greater than the value in the Ground level field.

Advice

Check the level parameters of the node.

E2088

The weir behaviour depth is less than or equal to the curb opening height of <opening height value>

Info

Node ID

Cause

Applicable to nodes with Flood type of Inlet or Inlet 2D and Inlet type of SagC or SagCO.

The Weir behaviour depth field is not greater than the value in the Opening height field.

Advice

Set the Weir behaviour depth to a value greater than the Opening height.

E2089

Node of type 'Connect 2D' and connection type '2D' must be inside a 2D zone's boundary

Info

Node

Cause

A Connect 2D type of node with a connection type of 2D is not located within a 2D zone.

Advice

Either move the node so that it is located within a 2D zone or change the type of node in the Node type field or the type of connection in the Connection type field.

E2090

Node of type 'Connect 2D' and connection type 'Break' must be connected to exactly 2 conduits of type 'Conduit 2D' or 'Linear Drainage 2D'

Info

Node

Cause

A Break type of Connect 2D node is not currently connected to two conduits which are of the type Conduit (2D) or Linear Drainage (2D).

Advice

Ensure that the Connect 2D node of type Break is connected to two conduits (one at either end) of the type Conduit (2D) or Linear Drainage (2D), or change the type of connection node in the Connection type field, or the type of conduit in the Conduit type field.

E2091

Node of type 'Connect 2D' can only be connected to conduits of type 'Conduit 2D' or 'Linear Drainage 2D'

Info

Node (Connectivity)

Cause

A Connect 2D node is not currently connected to a conduit which is of the type Conduit (2D) or Linear Drainage (2D).

Advice

Ensure that the Connect 2D node is connected to a conduit of the type Conduit (2D) or Linear Drainage (2D), or change the type of connection node in the Connection type field, or the type of conduit in the Conduit type field.

E2092

Linked by 2D conduits(s) to node <node id> which is connected to a different 2D zone

Info

Node ID

Cause

Either a single conduit of type Conduit (2D) or Linear Drainage (2D), or a chain of them, is connected (at either end) to 2 different Connect 2D nodes of connection type 2D, which are located in different 2D zones.

Note that this message is displayed for each node at either end of the conduit or chain of conduits.

Advice

A single Conduit (2D) or Linear Drainage (2D) type of conduit or a chain must be connected to nodes that are located in the same 2D zone. Therefore, move the applicable nodes so that they are located within the same 2D zone.

E2093

Linked by 2D conduits(s) to conduit <conduit id> which is connected to a different 2D zone

Info

Node

Cause

Two or more conduits of the type Linear Drainage (2D), which are connected to Connect 2D nodes with the connection type 2D, are located in different 2D zones.

Advice

Move the conduit(s), and any associated Connect 2D nodes of the type 2D, if applicable, so that they are located within the same 2D zone.

E2094

Must be either CIRC or RECT for conduit types 'Conduit (2D)' or 'Linear Drainage (2D)'

Info

Conduit

Cause

The Shape ID field is not set to either CIRC or RECT. Conduits with their Conduit type set to Conduit 2D or Linear Drainage 2D must have a Shape ID set to either CIRC or RECT.

Advice

Either change the Shape ID field to either CIRC or RECT, or change the Conduit type field to Conduit.

E2095

Must be N (Manning's n) for conduit types 'Conduit (2D)' or 'Linear Drainage (2D)'

Info

Conduit (Top/Bottom roughness)

Cause

The Roughness type field is not set to N (Manning's n). Conduits with their Conduit type set to Conduit 2D or Linear Drainage 2D must have the Roughness type field is set to N (Manning's n).

Advice

Either change the Roughness type field to N (Manning's n) or change the Conduit type field to Conduit.

E2096

Top and bottom roughness be Manning's n values must be the equal for conduit types 'Conduit (2D)' or 'Linear Drainage (2D)'

Info

Conduit (Roughness type)

Cause

The Roughness type field is set to N (Manning's n) and the Conduit type is set to either Conduit 2D or Linear Drainage 2D. But the different values have been specified for the Top roughness and Bottom roughness fields; these should be the same.

Advice

Either specify the same value for the Top roughness and Bottom roughness fields, or change the Conduit type field to Conduit.

E2097

Slot width must not exceed conduit width

Info

Conduit

Cause

The specified width for the slot is greater than the width specified for the conduit.

Advice

Either change the value specified in the Slot width field so that it is smaller than width for the conduit (specified in the Width field), or increase the value in the conduit Width field.

E2098

Conduit of type 'Linear drainage (2D)' must be fully inside a single 2D zone's boundary

Info

Conduit ID

Cause

One or more conduits of type of Linear drainage (2D) are not located with the same 2D zone.

Advice

Ensure that a single Linear drainage (2D) type of conduit, or all the conduits which comprise a chain of them, are located within the same 2D zone boundary. Move the applicable conduit(s) if necessary.

E2099

Conduit of type '<conduit type>' must be connected to at least one node of type 'Connect 2D'

Info

Conduit ID

Cause

A conduit of type Linear drainage (2D) or Conduit 2D is not connected to a node of type Connect 2D but it must be connected to at least one node of that type.

Advice

Ensure that the node selected in the conduit's US Node ID or DS Node ID field is a Connect 2D type of node.

E2100

Linked by 2D conduits(s) to conduit <conduit id> which is connected to a different 2D zone

Info

Conduit ID

Cause

Two or more conduits of the type Linear Drainage (2D) are located in different 2D zones.

Advice

Move the conduit(s), and any associated Connect 2D nodes of the type 2D if applicable, so that they are located within the same 2D zone.

E2101

Less than minimum flow

Info

Orifice ID

Cause

Applicable to VLDorf link types.

Maximum flow < Minimum Flow.

Advice

Check the Regulator parameters of the reported VLDorf object.

E2101

Below attached node's lowest storage level

Info

Orifice ID

Cause

Applicable to Orifice objects linked to Nodes of type Storage.

Invert Level of orifice < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check invert levels of orifice and Storage Node Level values.

E2102

Below attached node's chamber floor

Info

Orifice ID

Cause

Applicable to Orifice objects linked to Nodes of type Manhole.

Invert Level of Orifice < Chamber Floor Level of connected node.

Advice

Check invert levels of connected links and Node Levels.

E2103

No Bridge inlet/outlet exists with ID <inlet/outlet ID>

Info

Bridge Opening ID

Cause

An ID has been entered in the Inlet ID / Outlet ID field of the bridge opening, but a bridge inlet/outlet of that name does not exist in the network.

Advice

Review Inlet ID / Outlet ID values.

E2104

Cannot specify both an Inlet ID and an Inlet Blockage ID

Info

Bridge Opening - Inlet ID

Cause

An ID has been specified for the Inlet ID and Inlet Blockage ID fields of the bridge opening, but you can only specify one or the other; not both at the same time.

Advice

Select an Inlet ID or an Inlet Blockage ID.

E2105

Not linked to either Connect 2D node of connection type '2D' or, via a chain of conduits, to a conduit of type 'Linear Drainage (2D)'

Info

Conduit

Cause

A conduit of type Conduit (2D) is not currently connected to either a Connect 2D node of connection type 2D, or via a chain of conduits to a conduit type of Linear Drainage (2D).

Advice

Check the connections for this conduit or change it's Connection type.

E2106

The Min space step field cannot exceed the Max space step field defined for the network’s simulation parameters

Info

Conduit

Cause

The Max space step field specified for this network's simulation parameters is smaller than the Min space step defined for this Conduit 2D type of conduit.

Advice

Change the Min space step for the conduit so that it is smaller than the Max space step set in the simulation parameters. Alternatively, increase the Max space step set in the simulation parameters but this may affect the results for other objects in the network when a simulation is run.

E2107

Linked by 2D conduits(s) to node <node id> which is connected to a different 2D zone

Info

Conduit

Cause

Two or more conduits of the type Linear Drainage (2D) are connected to Connect 2D nodes of type 2D which are located in different 2D zones.

Advice

Move the Connect 2D nodes of the type 2D, and any associated Linear Drainage (2D) conduits, if applicable, so that they are located within the same 2D zone.

E2108

Not linked to a Connect 2D node of connection type '2D'

Info

Conduit

Cause

A single conduit of type Conduit (2D) is not currently connected to a Connect 2D node of connection type 2D.

Advice

If the conduit is connected to a Connect 2D node then ensure that the Connection type for the node is set to 2D. Otherwise, set the Node type to Connect 2D node and the Connection type to 2D.

E2126

Not in head discharge table

Info

Pump ID

Cause

Applicable to pumps of Link type ScrPmp and RotPmp.

Head Discharge object selected in the Head Discharge Table field of the Pump object has not been defined.

Advice

Define new Head Discharge Table or select an existing table.

E2126

Minimum speed > Nominal Speed > Maximum Speed

Info

Pump ID

Cause

Applicable to pumps of Link type VfdPmp

This error message may be displayed for the following reasons:

  • Minimum Speed is greater than Maximum Speed
  • Nominal Speed is less than Minimum Speed
  • Nominal Speed is greater than Maximum Speed

Where:

Nominal Speed is defined in the Head Discharge table accessed from the Pump Definition page of the Pump property sheet.

Minimum Speed and Maximum Speed are defined on the Regulator page of the Pump property sheet.

Advice

Review speed values for the pump.

E2127

Less than minimum flow

Info

Pump ID

Cause

Applicable to VspPmp link types.

Maximum flow < Minimum Flow.

Advice

Check the Regulator parameters of the reported VspPmp object.

E2127

Springing height must be less than height

Info

Bridge Opening ID

Cause

Bridge Opening Shape ID is set to SPRUNGARCH and opening Springing height is greater than opening Height.

Advice

Check Springing height of opening

E2128

Less than switch off level

Info

Pump ID

Cause

Switch on level < Switch off level.

Advice

Check the Pump Definition fields of the reported Pump object.

E2128

Height of arch above springing must be less than half of width

Info

Bridge Opening ID

Cause

Bridge Opening Shape ID is set to SPRUNGARCH and opening Height - Springing height is greater than opening Width/2.

Advice

Check Springing height of opening.

E2151

Less than minimum opening

Info

Sluice ID

Cause

Applicable to VSGate objects.

Regulator parameter Maximum Opening < Minimum Opening.

Advice

Check the Regulator Parameters fields of the VSGate object.

E2151

Below attached node's lowest storage level

Info

Sluice ID

Cause

Applicable to Sluice objects linked to Nodes of type Storage.

Invert Level of Sluice < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check Sluice invert level and Storage Node Level values.

E2152

Below attached node's chamber floor

Info

Sluice ID

Cause

Applicable to Sluice objects linked to Nodes of type Manhole.

Invert Level of Sluice < Chamber Floor Level of connected node

Advice

Check invert levels of connected links and Node Levels.

E2153

Must be greater than Depth threshold 1

Info

Roughness definition

Cause

The value specified for Depth threshold 2 is less than the value specified for Depth threshold 1 but it must be greater.

Advice

Check the Depth threshold 1 and Depth threshold 2 values for the relevant Roughness definition object, and ensure that the value specified for Depth threshold 2 is greater than the value specified for Depth threshold 1.

E2176

Not in head discharge table

Info

User Control ID

Cause

Head Discharge object selected in the Head Discharge Table field of the User Control object has not been defined.

Advice

Define new Head Discharge Table or select an existing table.

E2176

Below attached node's lowest storage level

Info

User Control ID

Cause

Applicable to User Control objects linked to Nodes of type Storage.

Invert Level of User Control < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check invert levels of connected links and Storage Node Level values.

E2177

Below attached node's chamber floor

Info

User Control ID

Cause

Applicable to User Control objects linked to Nodes of type Manhole.

Invert Level of User Control < Chamber Floor Level of connected node.

Advice

Check invert levels of connected links and Node Levels.

E2177

TVD connector specified for input does not exist

Info

TVD Connector ID

Cause

The TVD connector specified in one of the Input fields does not exist in the network.

Advice

Review the TVD ID entered in the Input field.

If the ID refers to a TSDB data stream, prefix the ID with a '#'.

E2180

Connected object not found in network

Info

TVD Connector ID

Cause

Applicable to TVD Connectors.

Displayed if the Connected object id does not correspond with the ID of a network object of type specified in the Connected object type field.

Displayed if Connected object type is set to hw_rtc and the specified Connected object id does not correspond to an RTC table ID. (When referencing RTC tables, the reference should take the form RegulatorID.TableName for tables defined in regulators in the RTC, or TableName for tables defined in the Global section of the RTC.)

Advice

Review the Connected object type and Connected object id fields.

E2182

Input attribute is invalid or has wrong units

Info

TVD Connector ID

Cause

The Connection usage field is set to Input and the value in the Input attribute field does not have the same units as the Output units type specified.

Advice

Review the Input attribute and Output units type fields.

E2183

Result attribute is invalid or has wrong units

Info

TVD Connector ID

Cause

The Connection usage field is set to Comparison and the value in the Comparison result field does not have the same units as the Output units type specified.

Advice

Review the Comparison result and Output units type fields.
E2183

Object type and result type attribute not allowed for ARAM output

Info

TVD Connector ID

Cause

The selected Connected object type and the selected Comparison result are not a valid combination for ARMA post-processing.

Advice

Review the selection of the Connected object type and the Comparison result fields. The permitted combinations are listed in the TVD Connector Data Fields topic.
E2184

TVD connectors require at least one input

Info

TVD Connector ID

Cause

There are no values defined in any of the input fields.

Advice

Specify an Input (either TVD connector ID or data stream).

E2187

There can be at most one TVD connector with output units of evaporation or temperature

Info

TVD Connector ID

Cause

More than one TVD connector has Output units type set to EV -evaporation or CF - temperature.

Advice

Currently only one evaporation or temperature profile can be applied to the network using TVD connectors.

E2188

Invalid connector unit for output unit type

Info

TVD Connector ID

Cause

The type of unit selected in the Connector units field cannot be used with the unit type selected in the Output unit type field.

Advice

Change the item currently selected in either the Connector units or the Output unit type field.

E2190

ARMA model not defined

Info

ARMA ID

Cause

The name of the specified ARMA model either does not exist or is not fully defined.

Advice

Check that all the data fields for the ARMA model have been specified. Note that the Autoregressive and Moving average parameters can only be specified via the ARMA Property Sheet.

E2199

Must be FHWA. US/DS node <node id> is DS/US node of conduit <conduit id> which has DS/US headloss type FHWA

Info

Node ID, Conduit ID

Cause

The end of a conduit with headloss type that is not FHWA is connected to the end of another conduit with headloss type FHWA.

If one conduit has headloss type FHWA at an end connected to a manhole, all the pipes connected to that manhole must have FHWA headloss at the end connected to the manhole.

Advice

Review the headloss type fields of connected pipes.

E2201

Less than minimum value

Info

Weir ID

Cause

Applicable to VCWeir and VWWeir objects.

Regulator parameter Maximum Value < Minimum Value.

Advice

Check the Regulator Parameters fields of the Weir object.

E2202

The total weir width is insufficient to accommodate the notch(es)

Info

Weir ID

Cause

Applicable to TRWeir objects.

Notch Width x Number of Notches < Width.

Advice

Check the Weir Definition fields of the TRWeir object.

E2202

Below attached node's chamber floor

Info

Weir ID

Cause

Applicable to Weir objects linked to Nodes of type Manhole.

Invert Level of Weir < Chamber Floor Level of connected node.

Advice

Check invert levels of connected links and Node Levels.

E2203

The notch width is too narrow

Info

Weir ID

Cause

Applicable to TRWeir objects.

Notch Width < 0.5 x Notch Height.

Advice

Check the Weir Definition fields of the TRWeir object.

E2204

The total weir width is insufficient to accommodate the notch(es)

Info

Weir ID

Cause

Applicable to VNWeir objects.

Notch Height x 2 x tan(Notch Angle/2) x No. of Notches > Weir Width.

Advice

Check the Weir Definition fields of the VNWeir object.

E2205

Boundary of 2D zone has changed since meshing was performed

Info

2D Zone ID

Cause

The 2D Zone boundary was edited after the current 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current polygon boundary.

E2206

Maximum triangle area has changed since meshing was performed

Info

2D Zone ID

Cause

The value in the Maximum Triangle Area field of the 2D Zone is different to the area value used to create the current mesh.

Advice

Either reset the Maximum Triangle Area of the 2D Zone to the value used when the current mesh was created, or re-mesh the 2D Zone using the current Maximum Triangle Area value.

E2207

Minimum angle has changed since meshing was performed

Info

2D Zone ID

Cause

The value in the Minimum Angle field of the 2D Zone is different to the minimum angle value used to create the current mesh.

Advice

Either reset the Minimum Angle of the 2D Zone to the value used when the current mesh was created, or re-mesh the 2D Zone using the current Minimum Angle value.

E2208

Mesh zone <mesh zone id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Mesh Zone ID

Cause

The Mesh Zone identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the Mesh Zone.

Advice

Re-mesh the 2D Zone using the current set of mesh zones.

Alternatively, if the Mesh Zone was renamed, reset the Mesh Zone ID to the value used when the 2D mesh was created.

E2209

Mesh zone <mesh zone id> has had its maximum triangle area changed since meshing was performed

Info

2D Zone ID, Mesh Zone ID

Cause

The value in the Maximum Triangle Area field of the Mesh Zone is different to the area used when creating the current mesh in the 2D Zone.

Advice

Either reset the Maximum Triangle Area of the Mesh Zone to the value used when the 2D mesh was created, or re-mesh the 2D Zone using the current Mesh Zone Maximum Triangle Area value.

E2210

Mesh zone <mesh zone id> has had its boundary changed since meshing was performed

Info

2D Zone ID, Mesh Zone ID

Cause

The boundary of a Mesh Zone used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current Mesh Zone boundary.

E2211

Roughness zone <roughness zone id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Roughness Zone ID

Cause

The Roughness Zone identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the Roughness Zone.

Advice

Re-mesh the 2D Zone using the current set of Roughness Zones.

Alternatively, if the Roughness Zone was renamed, reset the Roughness Zone ID to the value used when the 2D mesh was created.

E2212

Roughness zone <roughness zone id> has had its boundary changed since meshing was performed

Info

2D Zone ID, Roughness Zone ID

Cause

The boundary of a Roughness Zone used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current Roughness Zone boundary.

E2213

Polygons belonging to voids category <category id> have changed since meshing was performed

Info

2D Zone ID, Polygon Category ID

Cause

The boundary of a Polygon object(s) belonging to the Polygons Category used to identify voids at the time of creating the current 2D mesh, was edited after the mesh was created.

This includes edits to polygons in the voids category that do not intersect the 2D Zone.

(Where voids have been derived from a file or layer, changes to the file or layer are not validated.)

Advice

Re-mesh the 2D Zone using the current Polygon set.

E2214

Lines belonging to break lines category <category id> have changed since meshing was performed

Info

2D Zone ID, Line Category ID

Cause

The geometry of a Line(s) belonging to the Line Category used to identify Break Lines at the time of creating the current 2D mesh, was edited after the mesh was created.

This includes edits to Lines in the Break Lines category that do not intersect the 2D Zone.

(Where Break Lines have been derived from a file or layer, changes to the file or layer are not validated.)

Advice

Re-mesh the 2D Zone using the current Line set.

E2215

Lines belonging to walls category <category id> have changed since meshing was performed

Info

2D Zone ID, Line Category ID

Cause

The geometry of a Line(s) belonging to the Line Category used to identify Walls at the time of creating the current 2D mesh, was edited after the mesh was created.

This includes edits to Lines in the Walls category that do not intersect the 2D Zone.

(Where Walls have been derived from a file or layer, changes to the file or layer are not validated.)

Advice

Re-mesh the 2D Zone using the current Line set.

E2216

Mesh zone <mesh zone id> has been added since meshing was performed

Info

2D Zone ID, Mesh Zone ID

Cause

The Mesh Zone identified has a Maximum Triangle Area defined and intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Mesh Zone.

Advice

Re-mesh the 2D Zone using the current set of mesh zones.

Alternatively, if the Mesh Zone was renamed, reset the Mesh Zone ID to the value used when the 2D mesh was created.

E2217

Roughness zone <roughness zone id> has been added since meshing was performed

Info

2D Zone ID, Roughness Zone ID

Cause

The Roughness Zone identified has a Roughness defined and intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Roughness Zone.

Advice

Re-mesh the 2D Zone using the current set of roughness zones.

Alternatively, if the Roughness Zone was renamed, reset the Roughness Zone ID to the value used when the 2D mesh was created.

E2223

Infiltration zone (2D) <infiltration zone id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Infiltration Zone ID

Cause

The Infiltration Zone identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the Infiltration Zone.

Advice

Re-mesh the 2D Zone using the current set of Infiltration Zones.

Alternatively, if the Infiltration Zone was renamed, reset the Infiltration Zone ID to the value used when the 2D mesh was created.

E2224

Infiltration zone (2D) <infiltration zone id> has had its boundary changed since meshing was performed

Info

2D Zone ID, Infiltration Zone ID

Cause

The boundary of an Infiltration Zone used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current Infiltration Zone boundary.

E2225

Infiltration zone (2D) <infiltration zone id> has been added since meshing was performed

Info

2D Zone ID, Infiltration Zone ID

Cause

The Infiltration Zone identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Infiltration Zone.

Advice

Re-mesh the 2D Zone using the current set of infiltration zones.

Alternatively, if the Infiltration Zone was renamed, reset the Infiltration Zone ID to the value used when the 2D mesh was created.

E2226

Infiltration Zone <infiltration zone id> has had its exclude from 2d meshing flag changed since meshing was performed

Info

2D Zone ID, Infiltration Zone ID

Cause

The setting of the Exclude from 2D meshing option of the Infiltration Zone identified has been changed since the current mesh in the 2D Zone was created.

Advice

Re-mesh the 2D Zone using the current infiltration zone settings.

Alternatively, reset the Exclude from 2D meshing option to the value used when the 2D mesh was created.

E2228

Element <element id>: Less than previous value

Info

Shape ID

Cause

Applicable to shape objects with the Normalised option checked.

Height values in the Shape geometry editor should be in ascending order. The height value in the entry identified is less than the height value in the previous entry.

Advice

Review the entries in the Shape geometry editor.

E2230

Mesh has not been created for 2D zone

Info

2D Zone ID

Cause

A 2D mesh has not been generated for the 2D Zone.

Advice

Generate a mesh for the 2D Zone.

E2231

Width must be > 0 for 0 < height <1

Info

Shape ID

Cause

Applicable to normalised symmetric user defined shapes:

This message will be displayed if in the Shape Geometry Editor a Width <= 0 is entered against a Height value > 0 or < 1

Advice

Check the values entered in the Shape Geometry Editor.

E2232

Roughness Zone <roughness zone id> has had its exclude from 2d meshing flag changed since meshing was performed

Info

2D Zone ID, Roughness Zone ID

Cause

The setting of the Exclude from 2D meshing option of the Roughness Zone identified has been changed since the current mesh in the 2D Zone was created.

Advice

Re-mesh the 2D Zone using the current roughness zone settings.

Alternatively, reset the Exclude from 2D meshing option to the value used when the 2D mesh was created.

E2233

Less than lhs

Info

Shape ID

Cause

Applicable to asymmetric user defined shapes:

This message will be displayed if in the Shape Description Grid a Right value < the corresponding Left value.

Advice

Check the values entered in the Shape Description Grid.

E2234

Width must be > 0 for 0 < height < 1

Info

Shape ID

Cause

Applicable to asymmetric user defined shapes:

This message will be displayed if in the Shape Description Grid a Left or Right value = 0 is entered against a Height value > 0 or < 1

Advice

Check the values entered in the Shape Description Grid.

E2235

Porous Wall <porous wall id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Porous Wall ID

Cause

The Porous Wall identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the Porous Wall.

Advice

Re-mesh the 2D Zone using the current set of Porous Walls.

Alternatively, if the Porous Wall was renamed, reset the Porous Wall ID to the value used when the 2D mesh was created.

E2236

Porous Wall <porous wall id> has had its boundary changed since meshing was performed

Info

2D Zone ID, Porous Wall ID

Cause

The Porous Wall identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Porous Wall.

Advice

Re-mesh the 2D Zone using the current set of porous walls.

Alternatively, if the Porous Wall was renamed, reset the Porous Wall ID to the value used when the 2D mesh was created.

E2237

Porous Wall <porous wall id> has been added since meshing was performed

Info

2D Zone ID, Porous Wall ID

Cause

The Porous Wall identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Porous Wall.

Advice

Re-mesh the 2D Zone using the current set of porous walls.

Alternatively, if the Porous Wall was renamed, reset the Porous Wall ID to the value used when the 2D mesh was created.

E2238

2D IC zone <2D IC Zone ID> has been deleted/renamed since meshing was performed

Info

2D Zone ID, 2D IC Zone ID

Cause

The 2D IC Zone identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the 2D IC Zone.

Advice

Re-mesh the 2D Zone using the current set of 2D IC Zones.

Alternatively, if the 2D IC Zone was renamed, reset the 2D IC Zone ID to the value used when the 2D mesh was created.

E2239

2D IC zone <2D IC Zone ID> has had its boundary changed since meshing was performed

Info

2D Zone ID, 2D IC Zone ID

Cause

The boundary of a 2D IC Zone used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current 2D IC Zone boundary.

E2240

2D IC zone <2D IC Zone ID> has been added since meshing was performed

Info

2D Zone ID, 2D IC Zone ID

Cause

The 2D IC Zone identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the 2D IC Zone.

Advice

Re-mesh the 2D Zone using the current set of 2D IC Zones.

Alternatively, if the 2D IC Zone was renamed, reset the 2D IC Zone ID to the value used when the 2D mesh was created.

E2241

Must enter a value for either maximum crest or maximum width

Info

Weirs

Cause

The type of weir is specified either as a Variable Crest Weir (VCWEIR) or a variable width weir (VWWEIR) but a maximum elevation has not been set in either the Maximum crest or the Maximum width fields.

Advice

Ensure that the maximum elevation is set in the Maximum crest field for a VCWEIR or in the Maximum width field for a VWWEIR or a VCWEIR (if the Maximum crest is not set for a VCWEIR, the specified Maximum width will be used instead).

E2242

Must enter a value for either minimum crest or minimum width

Info

Weirs

Cause

The type of weir is specified either as a Variable Crest Weir (VCWEIR) or a variable width weir (VWWEIR) but a minimum elevation has not been set in either the Minimum crest or the Minimum width fields.

Advice

Ensure that the minimum elevation is set in the Minimum crest field for a VCWEIR or in the Minimum width field for a VWWEIR or a VCWEIR (if the Minimum crest is not set for a VCWEIR, the specified Minimum width will be used instead).

E2246

<Field name> Exceeds gate height value / Exceeds maximum opening value

Info

Weirs

Cause

The type of weir is specified as a Gated Weir (GTWEIR) but the values specified in the Minimum opening, Maximum opening and/or Initial opening fields are greater than the value specified for the Gate height, and/or the value specified in the Minimum opening field is greater than the value for specified for the Maximum opening field.

Advice

Ensure that the values specified for the Minimum opening, Maximum opening and/or Initial opening fields are less than the specified Gate height, and/or the value specified for the Minimum opening field is less than the specified Maximum opening.

E2249

Porous Polygon <Porous Polygon ID> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Porous Polygon ID

Cause

The Porous Polygon identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the Porous Polygon.

Advice

Re-mesh the 2D Zone using the current set of Porous Polygons.

Alternatively, if the Porous Polygon was renamed, reset the Porous Polygon ID to the value used when the 2D mesh was created.

E2250

Porous Polygon <Porous Polygon ID> has had its boundary changed since meshing was performed

Info

2D Zone ID, Porous Polygon ID

Cause

The boundary of a Porous Polygon used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current Porous Polygon boundary.

E2251

Table must contain at least two entries

Info

Head Discharge ID

Cause

Head / Discharge Grid of the Head Discharge contains < 2 rows.

Advice

Check the Head / Discharge Grid entries of the reported Head Discharge

E2252

First value must be 0

Info

Head Discharge ID

Cause

The first value in the Head column of the Head / Discharge Grid of the Head Discharge is not equal to 0.

Advice

Check the Head / Discharge Grid entries of the reported Head Discharge.

E2253

Less than previous value

Info

Head Discharge ID

Cause

Applicable to objects with associated Head Discharge curves except for pumps of Link Type = ROTPMP:

Head values in the Head / Discharge Grid are in descending order i.e. type = Head descending (ROTPMP).

Advice

Check that the correct Head / Discharge Grid is associated with the object. Change Head / Discharge Grid to type Head ascending if necessary.

E2254

More than previous value

Info

Head Discharge ID

Cause

Applicable to pumps of Link Type = ROTPMP:

Head values in the Head / Discharge Grid are in ascending order i.e. type = Head ascending.

Advice

Check that the correct Head / Discharge Grid is associated with the pump. Change Head / Discharge Grid to type Head descending (ROTPMP) if necessary.

E2255

Porous Polygon <Porous Polygon ID> has been added since meshing was performed

Info

2D Zone ID, Porous Polygon ID

Cause

The Porous Polygon identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Simulation Polygon.

This error may be caused by renaming of the Porous Polygon.

Advice

Re-mesh the 2D Zone using the current set of porous polygons.

Alternatively, if the Porous Polygon was renamed, reset the Porous Polygon ID to the value used when the 2D mesh was created.

E2256

First value must be 0

Info

Head Discharge ID

Cause

The first value in the Discharge column of the Head / Discharge Grid of the Head Discharge is not equal to 0.

Advice

Check the Head / Discharge Grid entries of the reported Head Discharge.

E2257

Head must be zero when discharge is zero

Info

Head Discharge ID

Cause

Applicable to User Control of Link Type = Vortex.

The Discharge value corresponding with Head = 0 in the Head / Discharge Grid is not equal to 0.

Advice

Check the Head / Discharge Grid entries of the reported Head Discharge.

E2258

Less than previous value

Info

Head Discharge ID

Cause

Applicable to objects with associated Head Discharge curves except for pumps of Link Type = ROTPMP:

Discharge values in the Head / Discharge Grid are in descending order i.e. type = Head descending (ROTPMP).

Advice

Check that the correct Head / Discharge Grid is associated with the object. Change Head / Discharge Grid to type Head ascending if necessary.

When modelling a vortex control, modification of the head discharge curve is required to remove the negative gradient in the kickback flow region.

Suggested modification to vortex control curve

E2259

Subcatchment <subcatchment id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Subcatchment ID

Cause

The Subcatchment identified was used to create the current mesh in the 2D Zone, but no longer exists.

Subcatchments are only used to create a mesh when the 2D Zone option Apply rainfall etc directly to mesh elements is selected and the Apply rainfall etc option is set to outside subcatchments (outside subcatchments and buildings) .

This error may be caused as a result of renaming of the Subcatchment.

Advice

Re-mesh the 2D Zone using the current set of subcatchments.

Alternatively, if the Subcatchment was renamed, reset the Subcatchment ID to the value used when the 2D mesh was created.

E2260

Subcatchment <subcatchment id> has had its boundary changed since meshing was performed

Info

2D Zone ID, Subcatchment ID

Cause

The boundary of a Subcatchment used to create the 2D Zone mesh was edited after the 2D mesh was created.

Subcatchments are only used to create a mesh when the 2D Zone option Apply rainfall etc directly to mesh elements is selected and the Apply rainfall etc option is set to outside subcatchments (outside subcatchments and buildings).

Advice

Re-mesh the 2D Zone using the current set of Subcatchment boundaries.

E2261

Subcatchment <subcatchment id> has been added since meshing was performed

Info

2D Zone ID, Subcatchment ID

Cause

The Subcatchment identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Simulation Polygon.

Subcatchments are only used to create a mesh when the 2D Zone option Apply rainfall etc directly to mesh elements is selected and the Apply rainfall etc option is set to outside subcatchments (outside subcatchments and buildings).

This error may be caused by renaming of the Subcatchment.

Advice

Re-mesh the 2D Zone using the current set of Subcatchments.

Alternatively, if the Subcatchment was renamed, reset the Subcatchment ID to the value used when the 2D mesh was created.

E2263

River reach <river reach id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, River Reach ID

Cause

The River Reach identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the nodes to which the River Reach is connected.

Advice

Re-mesh the 2D Zone using the current set of River Reaches.

Alternatively, if the River Reach was renamed, reset the IDs of the connecting nodes to the value used when the 2D mesh was created.

E2264

River reach <river reach id> has had its boundary changed since meshing was performed

Info

2D Zone ID, River Reach ID

Cause

The boundary of a River Reach used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current River Reach boundary.

E2267

River reach <river reach id> has been added since meshing was performed

Info

2D Zone ID, River Reach ID

Cause

The River Reach identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the nodes to which the River Reach is connected.

Advice

Re-mesh the 2D Zone using the current set of River Reaches.

Alternatively, if the River Reach was renamed, reset the IDs of the connecting nodes to the value used when the 2D mesh was created.

E2268

A value must be specified for this field when applying rainfall directly to mesh elements

Info

2D Zone ID

Cause

The Apply rainfall etc directly to mesh elements option of the 2D Zone has been selected, but a Rainfall Profile value has not been entered.

Advice

Enter a Rainfall Profile value.

E2270

Bridge <bridge id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Bridge ID

Cause

The Bridge identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the nodes to which the Bridge is connected.

Advice

Re-mesh the 2D Zone using the current set of Bridges.

Alternatively, if the Bridge was renamed, reset the IDs of the connecting nodes to the value used when the 2D mesh was created.

E2271

Bridge <bridge id> has had its boundary changed since meshing was performed

Info

2D Zone ID, Bridge ID

Cause

The boundary of a Bridge used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current Bridge boundary.

E2272

Bridge <bridge id> has been added since meshing was performed

Info

2D Zone ID, Bridge ID

Cause

The Bridge identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the nodes to which the Bridge is connected.

Advice

Re-mesh the 2D Zone using the current set of Bridges.

Alternatively, if the Bridge was renamed, reset the IDs of the connecting nodes to the value used when the 2D mesh was created.

E2273

Storage area <storage area id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Storage Area ID

Cause

The Storage Area identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the Storage Area.

Advice

Re-mesh the 2D Zone using the current set of Storage Areas.

Alternatively, if the Storage Area was renamed, reset the Storage Area ID to the value used when the 2D mesh was created.

E2274

Storage area <storage area id> has had its boundary changed since meshing was performed

Info

2D Zone ID, Storage Area ID

Cause

The boundary of a Storage Area used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current Storage Area boundary.

E2275

Storage area <storage area id> has been added since meshing was performed

Info

2D Zone ID, Storage Area ID

Cause

The Storage Area identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Storage Area.

Advice

Re-mesh the 2D Zone using the current set of Storage Areas.

Alternatively, if the Storage Area was renamed, reset the Storage Area ID to the value used when the 2D mesh was created.

E2276

More than initial infiltration

Info

Runoff Surface ID

Cause

Applicable to Runoff Surfaces with Runoff Volume Type = Horton or HortonSWMM.

Limiting infiltration value > Initial infiltration value.

Advice

Check the Infiltration parameters of the reported Runoff Surface.

E2279

Not greater than 0.000

Info

Runoff Surface ID

Cause

Applicable to Runoff Surfaces with Runoff Volume Type = HortonSWMM.

Horton drying time value < 0

Advice

Check the Infiltration parameters of the reported Runoff Surface.

E2280

Less than minimum runoff

Info

Runoff Surface ID

Cause

Applicable to Runoff Surfaces with Runoff Volume Type = Wallingfrd.

Wal. Proc. Minimum runoff value > Wal. Proc. Maximum runoff value.

Advice

Check the runoff parameters of the reported Runoff Surface.

E2281

Infiltration zone (2D) <infiltration zone id> has been added since meshing was performed

Info

2D Zone ID, Infiltration Zone ID

Cause

The Infiltration Zone identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Infiltration Zone.

Advice

Re-mesh the 2D Zone using the current set of infiltration zones.

Alternatively, if the Infiltration Zone was renamed, reset the Infiltration Zone ID to the value used when the 2D mesh was created.

E2281

This runoff volume type is inappropriate for impervious surfaces

Info

Runoff Surface ID

Cause

Applicable to Runoff Surfaces with Runoff Volume Type = Horton, HortonSWMM, NewUK, GreenAmpt, ConstInf and UKWIRPerv.

Surface Type field has been set to Impervious.

Advice

Check the Runoff Surface parameters are as expected.

E2282

SCS initial loss is only valid on SCS and CN runoff volumes

Info

Runoff Surface ID

Cause

Applicable to Runoff Surfaces using Runoff Volume Types other than SCS and CN.

Initial Loss Type field has been set to SCS.

Advice

Check the Runoff Surface parameters are as expected.

E2283

ReFH runoff volume type must have ReFH runoff routing type

Info

Runoff Surface ID

Cause

Runoff Volume Type is ReFH but Routing Model is not ReFH or vice versa.

Advice

Check the Runoff Surface parameters are as expected.

E2284

This runoff volume type is inappropriate for pervious surfaces

Info

Runoff Surface ID

Cause

Applicable to Runoff Surfaces with Runoff Volume Type = UKWIRPaved.

Surface Type field has been set to Pervious.

Advice

Check the Runoff Surface parameters are as expected.

E2287

Minimum element area has changed since meshing was performed

Info

2D Zone ID

Cause

The value of the Minimum element area field has been changed since the current 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current minimum element area.

E2287

The 'Cascade' routing model does not support the 'Rel' routing type, except when the number of reservoirs is zero

Info

Runoff Surface

Cause

The Routing model is set to Cascade, the Runoff routing type is set to Rel and the specified Number of reservoirs is greater than zero, but the Cascade model can only be used with a Rel routing type if the number of reservoirs is set to 0.

Advice

Either select a different Routing model or Runoff routing type, or if you want to use the Cascade model with Runoff routing type set to Rel, change the Number of reservoirs to 0.

E2288

Mesh zone <mesh zone id> has had its minimum element area changed since meshing was performed

Info

2D Zone ID, Mesh Zone ID

Cause

The value of the Minimum element area field or the status of the Override 2D zone minimum element area field has been changed since the current 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current mesh zone settings.

E2292

Terrain-sensitive meshing option has changed since meshing was performed

Info

2D Zone ID

Cause

The status of the Terrain-sensitive msehing field of the 2D Zone has been changed since the current 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current settings.

E2294

Maximum height variation must be specified for terrain-sensitive meshing

Info

2D Zone ID

Cause

The Terrain-sensitive meshing option for the 2D Zone has been checked, but a value has not been entered in the Maximum height variation field.

Advice

Enter a Maximum height variation for the 2D Zone.

E2295

Linear Structure (2D) <linear structure id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Linear Structure (2D) ID

Cause

The Linear Structure (2D) identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the Linear Structure (2D).

Advice

Re-mesh the 2D Zone using the current set of Linear Structure (2D) objects.

Alternatively, if the Linear Structure (2D) was renamed, reset the ID to the value used when the 2D mesh was created.

E2296

Linear Structure (2D) <linear structure id> has had its boundary changed since meshing was performed

Info

2D Zone ID, Linear Structure (2D) ID

Cause

The Linear Structure (2D) identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Linear Structure (2D).

Advice

Re-mesh the 2D Zone using the current set of Linear Structure (2D) objects.

Alternatively, if the Linear Structure (2D) was renamed, reset the ID to the value used when the 2D mesh was created.

E2297

Linear Structure (2D) <linear structure id> has been added since meshing was performed

Info

2D Zone ID, Linear Structure (2D) ID

Cause

The Linear Structure (2D) identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Linear Structure (2D).

Advice

Re-mesh the 2D Zone using the current set of Linear Structure (2D) objects.

Alternatively, if the Linear Structure (2D) was renamed, reset the ID to the value used when the 2D mesh was created.

E2298

Base linear Structure (2D) <base linear structure id> has had its sluice/bridge (2D) sub-structures changed since meshing was performed

Info

2D Zone ID, Base Linear Structure (2D) ID

Cause

May be caused by the following:

  • Fields affecting the geometry of a Sluice / Bridge Linear Structure (2D) object associated with the Base Linear Structure (2D) identified have been changed since the 2D Zone was meshed.
  • A new Sluice / Bridge Linear Structure (2D) object has been associated with the Base Linear Structure (2D), or an existing associated object has been renamed.
  • A Sluice /Bridge Linear Structure (2D) object that was associated with the Base Linear Structure (2D) is no longer associated with the structure, or has been renamed.

Advice

Re-mesh the 2D Zone using the current set of Sluice /Bridge Linear Structure (2D) objects.

E2299

Mesh zone <mesh zone id> has had its ground level modification type changed since meshing was performed

Info

Mesh Zone ID

Cause

The Ground level modification field of the Mesh Zone identified has been changed since the current mesh in the 2D Zone was created.

Advice

Re-mesh the 2D Zone using the current mesh zone settings.

E2300

Mesh zone <mesh zone id> has had its level adjustment changed since meshing was performed

Info

Mesh Zone ID

Cause

The Raise by or Level field (used for ground level modification) of the Mesh Zone identified has been changed since the current mesh in the 2D Zone was created.

Advice

Re-mesh the 2D Zone using the current mesh zone settings.

E2301

No corresponding surface index in land use

Info

Subcatchment ID

Cause

A value has been specified in a Subcatchment Runoff Area with no corresponding Surface ID defined in the associated Land Use.

Advice

Check that all Surface IDs have been defined in Land Use associated with the reported Subcatchment.

E2302

Not in land use set

Info

Subcatchment ID

Cause

Node selected in Subcatchment Land Use ID field does not exist or Land Use ID has not been specified.

Advice

Check that correct Subcatchment Land Use ID has been selected.

E2304

Time to peak must be greater than or equal to zero

Info

Subcatchment ID

Cause

Time to peak field on the Runoff Page of the Subcatchment Property Sheet is less than zero and the Routing Model field on the Runoff Surfaces grid is set to Unit, SCS Unit or ReFH.

Advice

Enter a Time to peak value greater than or equal to zero for the Subcatchment.

E2305

Base time must be greater than or equal to zero

Info

Subcatchment ID

Cause

Base time field on the Runoff Page of the Subcatchment Property Sheet is less than zero and the Routing Model field on the Runoff Surfaces grid is set to Unit or SCS Unit.

Advice

Enter a Base time value for the Subcatchment.

E2306

Catchment dimension must be non-zero

Info

Subcatchment ID

Cause

Applies to Subcatchments where Runoff Surfaces use Routing Model: SWMM, Desbordes or LargeCatch:

The warning message will be displayed if there is a contributing surface area (sum of the Subcatchment Runoff Areas > 0) but the Subcatchment Dimension field <= 0.

Advice

Check the Subcatchment Parameters.

E2307

Not in node set

Info

Subcatchment ID

Cause

Node selected in the Subcatchment Node ID or Ground infiltration node field does not exist or Node ID has not been specified.

Advice

Check that correct Subcatchment Node ID has been selected.

E2308

Nonexistent link <link sufffix> specified to drain to

Info

Subcatchment

Cause

The subcatchment is specified to drain to a link but the specified link suffix does not exist.

Advice

Check the subcatchment definition is as expected.

E2310

Subcatchments cannot drain to outfalls

Info

Subcatchment

Cause

Node selected in Subcatchment Node ID field is of type Outfall.

Advice

Check that the correct node has been selected in the Subcatchment Node ID field.

E2311

Not in ground infiltration set

Info

Subcatchment ID

Cause

Ground Infiltration data selected in the Ground Infiltration ID field of the Subcatchment object has not been defined.

Advice

Define new Ground Infiltration data or select an existing Ground Infiltration.

E2315

An ReFH unit hydrograph must be defined if the routing model is of type ReFH

Info

Subcatchment ID

Cause

The runoff surface associated with the subcatchment is an ReFH surface, but the Unit hydrograph definition specified is not ReFH.

Advice

Set Unit hydrograph definition to ReFH for ReFH runoff surfaces.

E2317

Incorrect routing definition for this routing model

Info

Subcatchment ID

Cause

The Unit hydrograph definition specified for the subcatchment can not be used with the Routing Model selected for the associated runoff surface.

For example, a Routing Model of Snyder Unit can only use a Unit Hydrograph Definition of Snyder.

Advice

Check Subcatchment Unit hydrograph definition and Runoff Surface Routing Model fields are set as expected.

E2318

Network results line (2D) <results line ID> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Network Results Line (2D) ID

Cause

The Network Results Line (2D) identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the network results line.

Advice

Re-mesh the 2D Zone using the current set of Network Results Lines.

Alternatively, if the results line was renamed, reset the results line ID to the value used when the 2D mesh was created.

E2319

Network results line (2D) <results line ID> has had its boundary changed since meshing was performed

Info

2D Zone ID, Network Results Line (2D) ID

Cause

The boundary of a Network Results Line (2D) used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current Network Results Line boundary.

E2319

Inline Bank has RTC but invalid 2D Zone

Info

Inline Bank ID

Cause

RTC Definitions have been specified in the Section data of the Inline Bank and either a 2D Zone ID has not been specified, or a 2D Zone ID that does not exist in the network has been specified.

Advice

Connect the Inline Bank to a 2D Zone by specifying a valid 2D zone ID.

E2320

Network results line (2D) <results line ID> has been added since meshing was performed

Info

2D Zone ID, Network Results Line (2D) ID

Cause

The Network Results Line (2D) identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Network Results Line (2D).

Advice

Re-mesh the 2D Zone using the current set of Network Results Lines.

Alternatively, if the line was renamed, reset the ID to the value used when the 2D mesh was created.

E2321

Network results polygon (2D) <results polygon ID> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Network Results Polygon (2D) ID

Cause

The Network Results Polygon (2D) identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the network results polygon.

Advice

Re-mesh the 2D Zone using the current set of Network Results Polygons.

Alternatively, if the results polygon was renamed, reset the results polygon ID to the value used when the 2D mesh was created.

E2322

Network results polygon (2D) <results polygon ID> has had its boundary changed since meshing was performed

Info

2D Zone ID, Network Results Polygon (2D) ID

Cause

The boundary of a Network Results Polygon (2D) used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current Network Results Polygon boundary.

E2323

Network results polygon (2D) <results polygon ID> has been added since meshing was performed

Info

2D Zone ID, Network Results Polygon (2D) ID

Cause

The Network Results Polygon (2D) identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Network Results Polygon (2D).

Advice

Re-mesh the 2D Zone using the current set of Network Results Polygons.

Alternatively, if the polygon was renamed, reset the ID to the value used when the 2D mesh was created.

E2326

Runoff surfaces have different routing models

Info

Land Use ID

Cause

The Runoff Surfaces associated with the Land Use object have different Routing Models.

Advice

Check the correct Runoff Surfaces have been associated with the reported Land Use object.

E2326

Stream name required

Info

Spatial rain source ID

Cause

The Stream name or category field is blank.

Advice

Specify a TSDB or STDSB data stream or a TVD connector Category.

E2327

This surface is not defined in runoff surfaces

Info

Land Use ID

Cause

The ID of a Runoff Surface that does not exist has been included in the Land Use Surfaces grid.

Advice

Define a new Runoff Surface or select an existing Runoff Surface.

E2328

A value must be specified for this field

Info

Subcatchment ID

Cause

The runoff routing model selected for the Runoff Surface for this subcatchment requires a Time to Peak (Tp) value, but a value for Tp has not been specified.

Advice

Specify a value for Tp on the Runoff page of the Subcatchment property sheet.

E2329

1D Results object associated with invalid upstream node

Info

Network Results Point (1D) ID

Cause

The node specified in the US node ID field of the Network Results Point (1D) does not exist in the network.

Advice

Specify a valid US node ID.

E2329

A value must be specified for this field

Info

Subcatchment ID

Cause

The runoff routing model selected for the Runoff surface for this subcatchment requires a Base time (Tb) value, but a value for Tb has not been specified.

Advice

Specify a value for Tb on the Runoff page of the Subcatchment property sheet.

E2329

You can only mix New UK runoff volume surfaces with fixed runoff volume surfaces

Info

Land Use ID

Cause

Runoff Surfaces associated with the reported Land Use include those of Runoff Volume Type = NewUK and Runoff Volume Type other than Fixed

Advice

Check that the correct Runoff Surfaces have been associated with the reported Land Use object.

Check the Runoff Volume Types assigned to associated Runoff Surfaces.

E2330

A Green-Ampt runoff volume surface can only be the last defined surface for a land use

Info

Land Use ID

Cause

More than one Runoff Surface associated with the reported Land Use is of Runoff Volume Type = GreenAmpt

or

A Runoff Surface of Runoff Volume Type = GreenAmpt is associated with the reported Land Use but is not the last surface in the Surfaces Tab of the Runoff Surfaces Property Sheet

Advice

Check that the correct Runoff Surfaces have been associated with the reported Land Use object.

Check the Runoff Volume Types assigned to associated Runoff Surfaces.

E2330

1D Results object associated with invalid link suffix

Info

Network Results Point (1D) ID

Cause

The link specified by the US node ID and Link suffix field of the Network Results Point (1D) does not exist in the network.

The node exists, but the link suffix is incorrect.

Advice

Specify a valid Link suffix.

E2331

1D Results object associated with invalid bridge opening

Info

Network Results Point (1D) ID

Cause

The bridge opening specified by the Bridge opening ID field of the Network Results Point (1D) does not exist in the network.

Advice

Specify a valid Bridge opening ID.

E2332

1D Results object must be associated with a link or bridge opening

Info

Network Results Point (1D) ID

Cause

Neither a Bridge opening ID or US node ID and Link suffix has been specified for the Network Results Point 1D

Advice

Specify a valid Bridge opening ID or valid US node ID and Link suffix.

E2332

Can only mix Wallingford runoff volume surfaces with fixed runoff volume surfaces

Info

Land Use ID

Cause

Runoff Surfaces associated with the reported Land Use include those of Runoff Volume Type = Wallingford and Runoff Volume Type other than Fixed

Advice

Check that the correct Runoff Surfaces have been associated with the reported Land Use object.

Check the Runoff Volume Types assigned to associated Runoff Surfaces.

E2333

Damage receptor <damage receptor id> has been deleted/renamed since 2d elements were last assigned

Info

2D Zone ID, Damage Receptor ID

Cause

The Damage Receptor identified was used to assign 2D elements to Damage Receptors, but no longer exists.

This error may be caused as a result of renaming of the Damage Receptor.

Advice

Re-assign the 2D elements using the current set of Damage Receptors.

Alternatively, if the Damage Receptor was renamed, reset the Damage Receptor ID to the value used when the 2D elements were assigned.

E2334

PDM runoff volume surface must be the first and only runoff surface

Info

Land Use ID

Cause

Multiple runoff surfaces associated with the reported Land Use including those of Runoff Volume Type = PDM.

A PDM runoff surface must be the only runoff surface associated with a subcatchment.

Advice

Check that the correct Runoff Surfaces have been associated with the reported Land Use object.

Check the Runoff Volume Types assigned to associated Runoff Surfaces.

E2335

Can only mix UKWIR surfaces with other UKWIR surfaces

Info

Land Use ID

Cause

Runoff Surfaces associated with the reported Land Use include those of Runoff Volume Type = UKWIRPaved or UKWIRPerv and Runoff Volume Type other than a UKWIR type.

Advice

Check that the correct Runoff Surfaces have been associated with the reported Land Use object.

Check the Runoff Volume Types assigned to associated Runoff Surfaces.

E2336

Cannot have more than one CNSWMM runoff volume surface

Info

Land use ID

Cause

Runoff surfaces associated with the reported Land use include more than one whose Runoff volume type is set to CNSWMM.

Advice

Check that there is only one Runoff surface, which is associated with the reported Land use object, that has a Runoff volume type set to CNSWMM.

E2337

Can only mix CNSWMM runoff volume surfaces with Fixed runoff volume surfaces

Info

Land use ID

Cause

Runoff surfaces associated with the reported Land Use include those of Runoff volume type = CNSWMM and Runoff volume type other than a Fixed type.

Advice

Check that the correct Runoff surfaces have been associated with the reported Land use object.

Check the runoff volume types assigned to the associated Runoff surfaces.

E2340

Inline Bank has 2D Zone specified but is not connected to an Outfall node

Info

Inline Bank ID

Cause

A 2D Zone ID has been specified for the Inline Bank, but the inline bank is not connected to an Outfall node.

Note: to model flow between the 1D network and a 2D mesh, the inline bank must be connected to a node of type Outfall, not Outfall 2D. An inline bank connected to a node of type Outfall 2D will be treated as a 1D link with flow entering the 2D zone at a point.

Advice

Connect the Inline Bank to a node of Node type Outfall.

E2341

A value must be specified for this field

Info

Subcatchment ID

Cause

An RefH runoff surface is associated with the subcatchment, but no unit hydrograph Time to peak, tp value has been specified.

Advice

Enter a Time to peak, tp value for the subcatchment.

E2342

Unit hydrograph peak must be greater than or equal to zero

Info

Subcatchment ID

Cause

Unit hydrograph Time to peak, tp value specified is less than zero.

Advice

Enter a Time to peak, tp value greater than or equal to zero for the subcatchment.

E2343

A value must be specified for this field

Info

Subcatchment ID

Cause

An RefH runoff surface is associated with the subcatchment, but no unit hydrograph Degree of kink value has been specified.

Advice

Enter a Degree of kink value for the subcatchment.

E2344

Degree of kink must be greater than or equal to zero

Info

Subcatchment ID

Cause

Unit hydrograph Degree of kink value specified is less than zero.

Advice

Enter a Degree of kink value greater than or equal to zero for the subcatchment.

E2348

A value must be specified for this field when runoff volume type is SRM or PDM on first runoff surface referenced

Info

Subcatchment ID

Cause

Runoff surface 1 of the Land Use associated with the reported Subcatchment is set to runoff surface with Runoff Volume Type = SRM or PDM and a value has not been entered in subcatchment SRM field, Baseflow calculation field or Soil moisture deficit field.

Advice

Enter value in subcatchment field causing validation error.

E2349

Must reference a PDM descriptor when baseflow calculation or soil moisture deficit set to 'PDM' and runoff surface runoff volume type is SRM

Info

Subcatchment ID

Cause

Runoff surface 1 of the Land Use associated with the reported Subcatchment is set to runoff surface with Runoff Volume Type = SRM and subcatchment Baseflow calculation and/or Soil moisture deficit fields are set to PDM, but a value has not been entered in the PDM descriptor field.

Advice

Enter value in subcatchment PDM descriptor field.

E2350

Must reference a PDM descriptor when runoff surface runoff volume type is PDM

Info

Subcatchment ID

Cause

Runoff surface 1 of the Land Use associated with the reported Subcatchment is set to runoff surface with Runoff Volume Type = PDM and a value has not been entered in subcatchment PDM descriptor field.

Advice

Enter value in subcatchment PDM descriptor field.

E2351

HOST SPR calculations need HOST soil class set

Info

Subcatchment ID

Cause

SPR calculation is set to HOST_Soils or HOST_FEH, but HOST soil class is not set.

Advice

Enter value in subcatchment HOST soil class field.

E2352

HOST predominant soils cannot have HOST soil class 28

Info

Subcatchment ID

Cause

SPR calculation is set to HOST_Soils and HOST soil class is set to 28.

(HOST predominant soils has no SPR defined for HOST=28)

Advice

Enter value in subcatchment HOST soil class field other than 28.

E2353

Standard percentage runoff must be set

Info

Subcatchment ID

Cause

Associated runoff surface is of type UKWIR, but Standard percentage runoff has not been set.

Advice

Enter value in subcatchment Standard percentage runoff field.

E2354

Value must be strictly greater than zero

Info

Subcatchment ID

Cause

Associated runoff surface has Routing model of type Non-linear, but subcatchment Slope has not been set or is less than zero.

(Slope is used to calculate values of K, p and lag time.)

or

Subcatchment Total area is greater than 2km2, Unit hydrograph definition is set to Rational and Time of concentration method is set to Kraven, but subcatchment Slope, Equivalent Manning's n or Hydraulic radius have been set to value less than or equal to zero.

(Slope, equivalent roughness and hydraulic radius are used to calculate flood wave celerity when catchment area is greater than 2km2.)

Advice

Enter value in subcatchment field.

E2355

ReFH/ReFH2 parameters are inconsistent with catchment descriptors

Info

Subcatchment ID

Cause

A catchment descriptor or option such as Country has been edited and is its parameter is no longer consistent with the specified ReFH or ReFH2 model.

or

The catchment descriptors are loaded and are different from the existing descriptors.

or

The parameters are imported from ReFH2 but the descriptors don’t match those on the dialog and they have not been updated.

or

The method for a descriptor is switched to “Design” and the design value is not available (either because it hasn’t been calculated yet or because the method was “User” when the dialog was opened).

Advice

Check that either the correct parameters or the model value is specified in subcatchment field.

E2356

Can only specify one of Node ID, To subcatchment ID, Lateral Links, 2D point source

Info

Subcatchment

Cause

More than one of the Drains to options has been specified for the subcatchment.

Advice

Check that the subcatchment only drains to either a Node ID or a To subcatchment ID or a set of Lateral links or a 2D point ID.

E2357

Must specify either a node , a link, a subcatchment, a 2D point source or a set of lateral links to drain to

Info

Subcatchment

Cause

The Drains to option for the subcatchment has not been specified.

Advice

Select the applicable option from the Drains to field and ensure that the name of the relevant object this subcatchment is to drain to is specified in the applicable Node ID, Link ID, To subcatchment ID or 2D point source field or in the Lateral links grid.

E2358

No subcatchment exists with this ID

Info

Subcatchment

Cause

The specified To subcatchment ID does not correspond to any subcatchment in the network.

Advice

Choose a subcatchment from the drop-down list in the To subcatchment ID field or create a new subcatchment with the required name/ID.

E2359

Cannot specify own ID as subcatchment to drain to

Info

Subcatchment

Cause

The name specified in the To subcatchment ID has the same name as the subcatchment. A subcatchment cannot drain into itself.

Advice

Choose a different subcatchment to drain to from the drop-down list in the To subcatchment ID field.

E2360

Specified ID results in a closed loop of drain to subcatchments

Info

Subcatchment

Cause

Following the chain of subcatchments specified in successive To subcatchment ID forms a closed loop.

Advice

To break the loop, choose a different subcatchment to drain to from the drop-down list in the To subcatchment ID field.

E2362

Uses ReFH2 version <number>. Other subcatchments in network use ReFH2 version <number>

Info

Subcatchment

Cause

The subcatchments in the network use different versions of ReFH2.

Advice

Ensure that all the subcatchments use the same version of ReFH2.

E2363

Must not be less than 0.001 when routing model is 'RAFTS'

Info

Runoff surface

Cause

The value specified for the Equivalent Manning's n field is less than the permitted minimum value of 0.001, when the runoff routing model is set to RAFTS.

Advice

In the runoff surface properties, either change the value for the Equivalent Manning's n field to one that is within the permitted range of 0.001 to 2.0, or choose a different routing model.

E2364

Must not exceed 2.0 when routing model is 'RAFTS'

Info

Runoff surface

Cause

The value specified for the Equivalent Manning's n field is more than the permitted maximum value of 2.0, when the runoff routing model is set to RAFTS.

Advice

In the runoff surface properties, either change the value for the Equivalent Manning's n field to one that is within the permitted range of 0.001 to 2.0, or choose a different routing model.

E2366

Unit hydrograph definition must be 'Name' if runoff surface has routing model 'Name'

Info

Subcatchment

Cause

The unit hydrograph selected in the Unit hydrograph definition field is different to that used by the routing model specified for the runoff surface. These must be the same.

Advice

Choose the relevant unit hydrograph from the drop-down list in the Unit hydrograph definition field.

E2367

Runoff surface must have routing model 'Name' if unit hydrograph definition is 'Name'

Info

Subcatchment

Cause

The routing model specified for the runoff surface uses a different unit hydrograph to that selected in the Unit hydrograph definition field. These must be the same.

Advice

Choose the relevant model from the dropdown list in the Routing model field on the Runoff surface tab in the Subcatchment grid.

Alternatively, access the Routing model field from the subcatchment property sheet by clicking next to the Land use ID field and selecting the Open Land use option from the context menu to display the Land use Object Properties sheet. Then click next to the relevant Runoff Surface field on the Land use Object Properties sheet and select the Open Runoff surface option from the context menu. This displays the Runoff surface Object Properties sheet from which the relevant Routing model can be selected.

E2368

Must specify a set of lateral links to drain to

Info

Subcatchment

Cause

You have specified that subcatchment must Drain to Multiple links but have not specified which links should be used.

Advice

Specify which links the subcatchment should drain to in the Lateral links field.

E2370

Groundwater cannot drain to outfalls

Info

Subcatchment

Cause

The Ground infiltration node is currently set to an outfall type of node but ground water cannot drain to an outfall node.

Advice

Select another ground infiltration node for the ground water to flow to.

E2374

SUDS structures' total area greater than that of the subcatchment

Info

Subcatchment

Cause

The total area of all the SUDS structures (Area x Number of units) located within this subcatchment is greater than the area of the subcatchment.

Advice

Check the Area and Number of units entries for each SUDS structure.

E2376

A headloss curve must contain 2-15 entries

Info

Headloss Curve ID

Cause

Ratio / Value Grid of the Headloss Curve contains < 2 or > 15 rows.

Advice

Check the Ratio / Value Grid entries of the reported Headloss Curve.

E2377

A headloss curve must contain 2-15 entries

Info

Headloss Curve ID

Cause

Velocity / Value Grid of the Headloss Curve contains < 2 or > 15 rows.

Advice

Check the Velocity / Value Grid entries of the reported Headloss Curve.

E2380

When not 'None' must have 'Recharge and Runoff' set to 'Standard' and 'Soil moisture distribution' set to 'Pareto'

Info

PDM Descriptor ID

Cause

The Interflow field of the PDM descriptor has been set to a value other than None and Recharge and runoff is not set to Standard and/or Soil moisture distribution is not set to Pareto.

Advice

Review the settings for the Interflow, Recharge and runoff and Soil moisture distribution fields.

E2381

A subcatchment with an RTK hydrograph must drain to a node if sim parameter "Use SWMM5 RDII" is selected

Info

RTK hydrograph

Cause

The Drains to field for the subcatchment is not currently set to Node.

Advice

Check that the Drains to field for the subcatchment is set to Node if SWMM5 RDII is to be used in the simulation.

Alternatively, uncheck the Use SWMM5 RDII option in the simulation parameters if this subcatchment is to drain to an object other than a node. Note that Monthly RTK Hydrographs can only be used in a simulation if the Use SWMM5 RDII option is selected.

E2382

Unit Hydrograph <ID> associated with multiple rainfall profiles (<Profile numbers>)

Info

Subcatchment

Cause

Subcatchments cannot use the same RTK hydrograph with different rainfall profiles.

Advice

Ensure that the subcatchments that use the same RTK hydrograph use the same rainfall profile.

E2384

Another subcatchment also with an RTK hydrograph drains to the same node and SWMM5 RDII is selected

Info

Node ID

Cause

The Use SWMM5 RDII option is selected in the simulation parameters but this subcatchment drains to the same node as another subcatchment for which an RTK Hydrograph is also specified; only one subcatchment with an RTK Hydrograph defined for it can drain to this node.

Advice

Check the specified Node ID and change if necessary.

Alternatively, uncheck the Use SWMM5 RDII box in the simulation parameters. Note that Monthly RTK Hydrographs can only be used in a simulation if the Use SWMM5 RDII option is selected.

E2385

<SUDS Structure ID> has product Area X (number of Units) greater than the area of surface(s) it occupies

Info

SUDS controls

Cause

The total area occupied by a SUDS structure (i.e. SUDS structure area × number of units) exceeds the area of the surface(s) on which they are located.

Advice

Check that the correct values have been entered in the Area and /or Number of units fields, or that the correct Surface has been selected for the SUDS control object.

E2388

Must not be less than 0.001 when routing model is 'RAFTS'

Info

Subcatchment

Cause

The value specified for the Equivalent Manning's n field is less than the permitted minimum value of 0.001, when the runoff routing model is set to RAFTS.

Advice

Either change the value for the Equivalent Manning's n field in the subcatchment properties to one that is within the permitted range of 0.001 to 2.0, or choose a different routing model in the runoff surface properties.

E2389

Must not exceed 2.0 when routing model is 'RAFTS'

Info

Subcatchment

Cause

The value specified for the Equivalent Manning's n field is more than the permitted maximum value of 2.0, when the runoff routing model is set to RAFTS.

Advice

Either change the value for the Equivalent Manning's n field in the subcatchment properties to one that is within the permitted range of 0.001 to 2.0, or choose a different routing model in the runoff surface properties.

E2390

Value must be greater than zero

Info

Subcatchment

Cause

The value specified for the Storage factor K is not greater than zero (0).

If the runoff routing model is set to Cascade or Non-linear, then Storage factor K must be greater than zero.

Advice

Change the value for the Storage factor K field to one that is greater than zero (>0), or check that the correct routing model has been specified.

If you want to use the Cascade routing model with a Storage factor K set to 0, then ensure, for all subcatchment surfaces, that either the Number of reservoirs is set to 0, or, the Runoff routing type is set to ABS and the Runoff routing value is greater than zero.

If you want to use the Non-linear routing model with a Storage factor K set to 0, then ensure, for all subcatchment surfaces, that either the Number of reservoirs is set to 0, or, the Runoff routing value is greater than zero.

E2392

When unit hydrograph definition is set to 'Rational' a time of concentration method must be selected

Info

Subcatchment ID

Cause

No option has been selected for the time of concentration method. When the Unit hydrograph definition is set to Rational, a method for calculating the time of concentration must be specified.

Advice

Select a method in the Time of concentration method field for the subcatchment identified in the message.
E2393

Element <element_ID>: Assigned node not found

Info

Subcatchment ID

Cause

A node has been specified in the Drain to node field of the SUDs control structure that is associated with this subcatchment, but this node does not exist.

Advice

Ensure that the applicable node is specified in the Drain to node field of the SUDs control structure properties. If the correct node has been specified, then check that it has been added to the relevant network.

E2394

Element <element_ID>: Assigned subcatchment not found

Info

Subcatchment ID

Cause

A subcatchment has been specified in the Drain to subcatchment field of the SUDs control structure that is associated with this subcatchment, but this subcatchment does not exist.

Advice

Ensure that the applicable subcatchment is specified in the Drain to subcatchment field of the SUDs control structure properties. If the correct subcatchment has been specified, then check that it has been added to the relevant network.

E2395

Must specify 2D point source to drain to

Info

Subcatchment

Cause

The Drains to field is set to 2D point source but you have not specified a 2D point source in the 2D point ID field.

Advice

Specify which 2D point source, in the 2D point ID field, that this subcatchment is to drain to.

E2396

2D point source to drain to not defined

Info

Subcatchment

Cause

The Drains to field has been specified as a 2D point source, but the 2D point source, specified in the 2D point ID field does not exist in this network.

Advice

Check that the appropriate 2D point source has been specified in the 2D point ID field, and either change if necessary, or ensure that the relevant 2D point source has been added for this network.

E2397

For Exceedance flow type '2D mesh' the subcatchment must drain to a node located inside a 2D mesh element.

Info

Subcatchment

Cause

The Exceedance flow type is set to 2D mesh but the subcatchment does not Drain to a node within a 2D mesh element.

Advice

Check that the Drains to field is set to Node, and that the node is located in a 2D mesh element. This can be any type of node except Outfall or Outfall 2D. Alternatively, change the Exceedance flow type.

E2402

Unit flow values must either be in ascending or descending order

Info

Head Unit Flow ID

Cause

The Unit flow values in the Head unit flow table editor must be specified in either ascending or descending order.

Advice

Review the Head and Unit flow values in the Head unit flow editor.

E2406

Overlaps with sluice/bridge linear structure (2D) <sluice/bridge linear structure (2D) id> on base linear structure <base linear structure (2D) id>

Info

Sluice/Bridge Linear Structure (2D) ID, Base Linear Structure (2D) ID

Cause

The Sluice/Bridge Linear Structure (2D) has Start length and Length values resulting in an overlap with another Sluice/Bridge Linear Structure (2D) object associated with the identified base linear structure.

Advice

Review the Start length and Length values of the 2D sluice/bridge.

E2407

Overlaps boundary of 2D zone <2D zone id>

Info

Bridge Linear Structure (2D) ID

Cause

The Bridge Linear Structure (2D) has Start length and Length values resulting in an overlap with a 2D zone boundary.

Advice

Review the Start length and Length values of the 2D bridge.

E2408

Must enter crest level values for all section data points

Info

Bridge Linear Structure (2D) ID

Cause

One or more Invert level values not specified in the Section data editor.

Advice

Enter Invert level values for all section data points.

E2409

Must enter opening height values for all section data points

Info

Bridge Linear Structure (2D) ID

Cause

One or more Opening height values not specified in the Section data editor.

Advice

Enter Opening height values for all section data points.

E2410

Must enter deck thickness values for all section data points

Info

Bridge Linear Structure (2D) ID

Cause

One or more Deck thickness values not specified in the Section data editor.

Advice

Enter Deck thickness values for all section data points.

E2426

Value must be strictly greater than zero

Info

Ground Infiltration ID, Ground Infiltration data field.

Cause

A value less than or equal to zero has been specified in a field of the Ground Infiltration object:

  • Soil depth
  • Percolation coefficient
  • Baseflow coefficient
  • Infiltration coefficient

Advice

Enter a value greater than zero in the data field identified.

E2426

Sediment fraction weights total to a value other than 1

Info

Sediment Grading ID

Cause

The sum of the sediment fraction weight values in the Sediment Grading is not equal to 1.

Advice

Review sediment fraction weights.

E2427

Must reference a linear structure (2D)

Info

Bridge Linear Structure (2D) ID

Cause

A value has not been specified in the Base linear structure (2D) ID field of the Bridge Linear Structure (2D).

Advice

Enter a Base linear structure (2D) ID for the 2D bridge.

E2428

Referenced linear structure (2D) does not exist in network

Info

Bridge Linear Structure (2D) ID

Cause

The linear structure specified in the Base linear structure (2D) ID field of the Bridge Linear Structure (2D) does not exist in the network.

Advice

Enter a valid Base linear structure (2D) ID for the 2D bridge.

E2436

Completely outside 2D zone boundary

Info

Bridge Linear Structure (2D) ID

Cause

The Bridge Linear Structure (2D) has Start length and Length values resulting in the structure being outside of any 2D zone.

Advice

Review the Start length and Length values of the 2D bridge.

E2451

Below attached node's lowest storage level

Info

Flume ID

Cause

Applicable to Flume objects linked to Nodes of type Storage.

Throat Level of downstream/upstream link < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check throat level of connected Flume and Storage Node Level values.

E2452

Mesh level zone <mesh level zone ID> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Mesh Level Zone ID

Cause

The Mesh Level Zone identified was used to create the current mesh in the 2D Zone, but no longer exists.

This error may be caused as a result of renaming of the Mesh Level Zone.

Advice

Re-mesh the 2D Zone using the current set of Mesh Level Zones.

Alternatively, if the Mesh Level Zone was renamed, reset the Mesh Level Zone ID to the value used when the 2D mesh was created.

E2453

Mesh level zone <mesh level zone ID> has had its boundary changed since meshing was performed

Info

2D Zone ID, Mesh Level Zone ID

Cause

The boundary of a Mesh Level Zone used to create the 2D Zone mesh was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current Mesh Level Zone boundary.

E2454

Mesh level zone <mesh level zone ID> has been added since meshing was performed

Info

2D Zone ID, Mesh Level Zone ID

Cause

The Mesh Level Zone identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Zone.

This error may be caused by renaming of the Mesh Level Zone.

Advice

Re-mesh the 2D Zone using the current set of Mesh Level Zones.

Alternatively, if the zone was renamed, reset the ID to the value used when the 2D mesh was created.

E2455

Mesh level zone <mesh level zone ID> has had its use lower limit setting changed since meshing was performed

Info

2D Zone ID, Mesh Level Zone ID

Cause

The setting of the Use lower limit field of the Mesh Level Zone identified was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone, or re-level the mesh using the Resample 2D Zone Elevations Dialog.

E2456

Mesh level zone <mesh level zone ID> has had its lower limit level changed since meshing was performed

Info

2D Zone ID, Mesh Level Zone ID

Cause

The value of the Lower limit level field of the Mesh Level Zone identified was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone, or re-level the mesh using the Resample 2D Zone Elevations Dialog.

E2457

Mesh level zone <mesh level zone ID> has had its use upper limit setting changed since meshing was performed

Info

2D Zone ID, Mesh Level Zone ID

Cause

The setting of the Use upper limit field of the Mesh Level Zone identified was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone, or re-level the mesh using the Resample 2D Zone Elevations Dialog.

E2458

Mesh level zone <mesh level zone ID> has had its upper limit level changed since meshing was performed

Info

2D Zone ID, Mesh Level Zone ID

Cause

The value of the Upper limit level field of the Mesh Level Zone identified was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone, or re-level the mesh using the Resample 2D Zone Elevations Dialog.

E2459

Mesh level zone <mesh level zone ID> has had its type changed since meshing was performed

Info

2D Zone ID, Mesh Level Zone ID

Cause

The value of the Type field of the Mesh Level Zone identified was edited after the 2D mesh was created.

Advice

Re-mesh the 2D Zone, or re-level the mesh using the Resample 2D Zone Elevations Dialog.

E2460

Mesh level zone <mesh level zone ID> has had its vertices elevation data changed since meshing was performed

Info

2D Zone ID, Mesh Level Zone ID

Cause

Edits were made to the values in the Vertices editor of the Mesh Level Zone identified after the 2D mesh was created.

Advice

Re-mesh the 2D Zone, or re-level the mesh using the Resample 2D Zone Elevations Dialog.

E2461

2D line source <line ID> has been deleted/renamed since meshing was performed

Info

2D Zone

Cause

The 2D Line Source has been deleted or renamed since the 2D mesh was created

Advice

Re-mesh the 2D Zone

E2462

2D line source <line ID> has been deleted/renamed since meshing was performed

Info

2D Zone, Z1

Cause

The 2D Line Source has had its boundary changed since the 2D mesh was created.

Advice

Check the geometry of the 2D line source, edit if necessary and then re-mesh.

E2463

2D line source <line ID> has been deleted/renamed since meshing was performed

Info

2D Zone, Z1

Cause

The 2D Line Source has been added since the 2D mesh was created.

Advice

Re-mesh the 2D zone.

E2465

Turbulence zone (2D) <turbulence zone id> has been deleted/renamed since meshing was performed

Info

2D Zone, Z2

Cause

The Turbulence Zone (2D) has been deleted or renamed since the 2D mesh was created.

Advice

Re-mesh the 2D zone.

E2466

Turbulence zone (2D) <turbulence zone id> has had its boundary changed since meshing was performed

Info

2D Zone, Z2

Cause

The Turbulence Zone (2D) has had its boundary changed since the 2D mesh was created.

Advice

Check the geometry of the Turbulence Zone (2D), edit if necessary and then re-mesh.

E2467

Turbulence zone (2D) <turbulence zone id> has been added since meshing was performed

Info

2D Zone, Z2

Cause

The Turbulence Zone (2D) has been added since the 2D mesh was created.

Advice

Re-mesh the 2D zone.

E2468

Turbulence zone (2D) <turbulence zone id> has had its exclude from 2d meshing flag changed since meshing was performed

Info

2D Zone, Z2

Cause

The setting for the Exclude turbulence zone boundary when creating 2D mesh field for the Turbulence Zone (2D) has changed since meshing was performed.

Advice

Check the setting, change if necessary, and then re-mesh the 2D zone.

E2469

Permeable zone (2D) <permeable zone id> has been deleted/renamed since meshing was performed

Info

2D Zone

Cause

The Permeable Zone (2D) has been deleted or renamed since the 2D mesh was created.

Advice

Re-mesh the 2D zone.

E2470

Permeable zone (2D) <permeable zone id> has had its boundary changed since meshing was performed

Info

2D Zone

Cause

The Permeable Zone (2D) has had its boundary changed since the 2D mesh was created.

Advice

Check the geometry of the Permeable Zone (2D), edit if necessary and then re-mesh.

E2471

Permeable zone (2D) <permeable zone id> has been added since meshing was performed

Info

2D Zone

Cause

The Permeable Zone (2D) has been added since the 2D mesh was created.

Advice

Re-mesh the 2D zone.

E2472

Permeable zone (2D) <permeable zone id> has had its exclude from 2d meshing flag changed since meshing was performed

Info

2D Zone

Cause

The setting for the Exclude permeable zone boundary when creating 2D mesh field for the Permeable Zone (2D) has changed since meshing was performed.

Advice

Check the setting, change if necessary, and then re-mesh the 2D zone.

E2473

Conduit of type 'Linear Drainage 2D' <conduit_id> has been deleted/renamed since meshing was performed

Info

2D Zone

Cause

The Linear Drainage 2D type of conduit has been renamed or deleted since the 2D mesh was created.

Advice

Re-mesh the 2D zone.

E2474

Conduit of type 'Linear Drainage 2D' <conduit_id> has had its boundary changed since meshing was performed

Info

2D Zone

Cause

The Linear Drainage 2D type of conduit has had its boundary changed since the 2D mesh was created.

Advice

Check the geometry of the appropriate Linear Drainage 2D type of conduit, edit if necessary and then re-mesh.

E2475

Conduit of type 'Linear Drainage 2D' <conduit_id> has been added since meshing was performed

Info

2D Zone

Cause

The Linear Drainage 2D type of conduit has been added since the 2D mesh was created.

Advice

Re-mesh the 2D zone.

E2476

The crown level must be above the crest level

Info

Siphon ID

Cause

Value entered in the Crest field of the Siphon object is >= Crown level.

Advice

Check the level values of the siphon object.

E2476

Below attached node's lowest storage level

Info

Siphon ID

Cause

Applicable to Siphon objects linked to Nodes of type Storage.

Outlet Level of Siphon < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check siphon outlet level and storage node level values.

E2477

The outlet level must be lower than the crest level

Info

Siphon ID

Cause

Value entered in the Crest field of the Siphon object is < Outlet level.

Advice

Check the level values of the siphon object.

E2477

Below attached node's chamber floor

Info

Siphon ID

Cause

Applicable to Siphon objects linked to Nodes of type Manhole.

Outlet Level of Siphon < Chamber Floor Level of connected node.

Advice

Check the siphon and node levels.

E2478

The priming level must be between the crest and crown levels

Info

Siphon ID

Cause

Value entered in the Priming field of the Siphon object is <= Crest or >= Crown level values.

Advice

Check the level values of the siphon object.

E2479

Hood soffit level must be between the crest and priming levels

Info

Siphon ID

Cause

Value entered in the Hood soffit level field of the Siphon object is <= Crest or > Priming level values.

Advice

Check the level values of the siphon object.

E2480

Conduit <conduit-id> has had its conduit type from 'Linear Drainage (2D)' changed since meshing was performed

Info

2D Zone

Cause

The setting for the Conduit type field has changed from Linear Drainage (2D) since meshing was performed. Only Linear Drainage (2D) types of conduits will be included in the mesh operation.

Advice

Check the setting, change if necessary, and then re-mesh the 2D zone.

E2481

Mesh generation has changed since meshing was performed

Info

2D Zone

Cause

The selected type of Mesh generation has changed since meshing was last performed.

Advice

Check the setting of the Mesh generation field, change if necessary, and then re-mesh the 2D zone.

E2485

Building <building id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Building ID

Cause

The Building identified was used to create the current mesh in the 2D Zone, but no longer exists.

Buildings are only used to create a mesh when the 2D Zone option Apply rainfall etc directly to mesh elements is selected and the Apply rainfall etc option is set to outside subcatchments (outside subcatchments and buildings).

This error may be caused as a result of renaming of the building or because the building has been deleted.

Advice

Re-mesh the 2D Zone using the current set of buildings.

Alternatively, if the Building was renamed, reset the Building ID to the value used when the 2D mesh was created.

E2486

Building <building id> has had its boundary changed since meshing was performed

Info

2D Zone ID, Building ID

Cause

The boundary of a Building used to create the 2D Zone mesh was edited after the 2D mesh was created.

Buildings are only used to create a mesh when the 2D Zone option Apply rainfall etc directly to mesh elements is selected and the Apply rainfall etc option is set to outside subcatchments (outside subcatchments and buildings).

Advice

Re-mesh the 2D Zone using the current set of buildings.

E2487

Building <building id> has been added since meshing was performed

Info

2D Zone ID, Building ID

Cause

The Building identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Simulation Polygon.

Buildings are only used to create a mesh when the 2D Zone option Apply rainfall etc directly to mesh elements is selected and the Apply rainfall etc option is set to outside subcatchments (outside subcatchments and buildings).

This error may be caused by renaming of the Building.

Advice

Re-mesh the 2D Zone using the current set of Buildings.

Alternatively, if the Building was renamed, reset the Building ID to the value used when the 2D mesh was created.

E2488

Building <building id> has had its Single element checkbox changed since meshing was performed

Info

Building ID

Cause

The setting of the Single element box for the Building has been changed after the 2D mesh was created.

Advice

Either change the setting of the Single element box or re-mesh the 2D Zone using the current Single element setting.

E2501

Below attached node's lowest storage level

Info

Screen ID

Cause

Applicable to Screen objects linked to Nodes of type Storage.

Crest Level of Screen < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check Screen crest level and Storage Node Level values.

E2502

Below attached node's chamber floor

Info

Screen ID

Cause

Applicable to Screen objects linked to Nodes of type Manhole.

Invert Level of Screen < Chamber Floor Level of connected node.

Advice

Check invert levels of connected links and Node Levels.

E2517

Must be contained within a 2D simulation polygon mesh element

Info

2D Point Source ID

Cause

The 2D Point Source identified is not located inside a meshed 2D simulation polygon.

Advice

Move 2D Point Source so that it is located inside a 2D Zone.

E2525

No profile specified

Info

Channel ID

Cause

There is no entry in the Shape ID field of the Channel object.

Advice

Enter a Channel Shape ID in the Shape ID field for the Channel object.

E2526

Below attached node's lowest storage level

Info

Channel ID

Cause

Applicable to Channel objects linked to Nodes of type Storage.

Upstream/Downstream Invert Level of downstream/upstream link < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check invert levels of connected links and Storage Node Level values.

E2527

Below attached node's chamber floor

Info

Channel ID

Cause

Applicable to Channel objects linked to Nodes of type Manhole.

Invert Level of Channel < Chamber Floor Level of connected node.

Advice

Check invert levels of connected links and Node Levels.

E2528

Channel sections must have at least one non-zero roughness value

Info

Channel Shape ID

Cause

In the Channel Profile grid of the Channel Shape object, all roughness values are set to zero.

Advice

Check roughness values in the Channel Profile grid of the Channel Shape object.

E2530

Invalid Date

Info

Water Quality and Sediment Parameters (Wash off)

Cause

An invalid date, such as February 31, has been specified for sweep start or end date.

Advice

Check the values specified in the Sweep start month, Sweep start day, Sweep end month and Sweep end day fields.

E2535

Bridge referenced by bridge opening not found in network

Info

Bridge Opening ID

Cause

The bridge object referenced by the Bridge US node ID and Bridge link suffix fields of the opening does not exist in the network.

Advice

Check Bridge US node ID and Bridge link suffix values.

E2543

Table must contain at least two entries

Info

Flow Efficiency Table ID

Cause

Flow / Efficiency Grid of the Flow Efficiency Table contains < 2 rows.

Advice

Check the Flow / Efficiency Grid entries of the reported Flow Efficiency table

E2545

Element <element id> Efficiency must be expressed as a fraction (between 0 and 1)

Info

Flow Efficiency Table ID

Cause

An efficiency value in the Flow / Efficiency Grid of the Flow Efficiency Table is not between the values of 0 and 1.

Advice

Enter efficiency values as a fraction.

E2545

Partially collinear with boundary of 2D simulation polygon <2D Zone ID>

Info

2D Boundary Line ID

Cause

The 2D Boundary Line identified does not fully coincide with the boundary of a 2D Zone.

Advice

Edit the 2D boundary line so that it is fully snapped to the boundary of the 2D Zone boundary.

E2546

Must be collinear with the boundary of a 2D Zone

Info

2D Boundary Line ID

Cause

The 2D Boundary line identified does not coincide exactly with the boundary of a 2D Zone.

Advice

Edit the 2D boundary line so that it is snapped to the boundary of the 2D Zone boundary.

E2549

Must enter a head unit flow table present in the network

Info

Head unit flow table

Cause

The Boundary line type has been set to Level & Head/discharge but the head unit flow table specified in the Head unit flow table field does not exist for this network.

Advice

Check that the correct head unit flow table has been specified. Note that the required head unit flow table may not have yet been added to this network.

E2551

A culvert inlet must have one outgoing link

Info

Culvert Inlet ID

Cause

The downstream node of the Culvert Outlet object is not connected to a link or is connected to more than one link.

Advice

Check the connectivity of the Culvert Inlet object.

E2551

Below attached node's lowest storage level

Info

Culvert Inlet ID

Cause

Applicable to Culvert Inlet objects linked to Nodes of type Storage.

Invert Level of Culvert Inlet < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check invert levels of connected links and Storage Node Level values.

E2552

The outgoing link for a culvert inlet must be a conduit of type other than 'culvert'

Info

Culvert Inlet ID

Cause

The downstream node of the Culvert Inlet object is connected to a link that is either not a conduit or is a conduit whose Conduit type is set to Culvert.

Advice

Check the connectivity of the Culvert Inlet object.

E2552

Below attached node's chamber floor

Info

Culvert Inlet ID

Cause

Applicable to Culvert Inlet objects linked to Nodes of type Manhole.

Invert Level of Culvert Inlet < Chamber Floor Level of connected node

Advice

Check invert levels of connected links and Node Levels.

E2553

A culvert inlet/conduit of type 'culvert' with the OUTLET reverse flow model must have one incoming link or an upstream node of type Outfall (including 2D)

Info

Culvert Inlet ID

Cause

Applicable to Culvert Inlet objects or, a Conduit with a Conduit type set to Culvert, which have a Reverse flow model set to Outlet.

The upstream node of the Culvert Inlet object is either connected to more than one link or not connected to an upstream node of type Outfall or Outfall 2D.

Advice

Check the connectivity of the Culvert Inlet object.

E2554

The incoming link for a culvert inlet/conduit of type 'culvert' with the OUTLET reverse flow model must be a conduit (not type 'culvert'), a channel or a river reach

Info

Culvert Inlet ID

Cause

The upstream node of the Culvert Inlet object, or a Conduit with a Conduit type set to Culvert, must be connected to either a channel, a river reach or a conduit (but not to a conduit whose Conduit type is set to Culvert).

Advice

Check the connectivity of the Culvert Inlet object.

E2555

FHWA is not valid as a US/DS headloss type for a channel, river reach or bridge

Info

Channel ID

Cause

The US/DS headloss type field of the channel has been set to FHWA.

(FHWA headloss condition is only valid for closed conduits.)

Advice

Review the US headloss type / DS headloss type values.

E2576

A culvert outlet must have one incoming link

Info

Culvert Outlet ID

Cause

The upstream node of the Culvert Outlet object is not connected to a link or is connected to more than one link.

Advice

Check the connectivity of the Culvert Outlet object.

E2576

Below attached node's lowest storage level

Info

Culvert Outlet ID

Cause

Applicable to Culvert Outlet objects linked to Nodes of type Storage.

Invert Level of Culvert Outlet < lowest level in connected Storage Node Level / Plan Area grid.

Advice

Check invert levels of connected links and Storage Node Level values.

E2577

The incoming link for a culvert outlet must be a conduit of type other than 'culvert'

Info

Culvert Outlet ID

Cause

The upstream node of the Culvert Outlet object must be connected to a conduit whose Conduit type is NOT set to Culvert.

Advice

Check the connectivity of the Culvert Outlet object.

E2577

Below attached node's chamber floor

Info

Culvert Outlet ID

Cause

Applicable to Culvert Outlet objects linked to Nodes of type Manhole

Invert Level of Culvert Outlet < Chamber Floor Level of connected node

Advice

Check invert levels of connected links and Node Levels.

E2578

A culvert outlet/conduit of type 'culvert' must have one outgoing link or a downstream node of type Outfall (including 2D)

Info

Culvert Outlet ID

Cause

The downstream node of the Culvert Outlet object, or a Conduit whose Conduit type is set to Culvert, is either:
  • connected to more than one link
  • not connected to a link
  • not connected to a downstream node of type Outfall or Outfall 2D

Advice

Check the connectivity of the Culvert Outlet object.

E2579

The outgoing link for a culvert outlet/conduit of type 'culvert' must be a conduit (not type 'culvert'), a channel or a river reach

Info

Culvert Outlet ID

Cause

The downstream node of the Culvert Inlet object, or a Conduit with a Conduit type set to Culvert, must be connected to either a channel, a river reach or a conduit (but not to a conduit whose Conduit type is set to Culvert).

Advice

Check the connectivity of the Culvert Outlet object.

E2616

Overlaps boundaries of multiple 2D zones, Z1, Z2

Info

2D Line Source (X,Y line)

Cause

The 2D Line Source overlaps the boundaries of multiple 2D zones.

Advice

Check the position of the 2D Line Source to ensure that it does not overlap more than one 2D zone.

E2628

Channel shape profiles must have at least one non-zero roughness value

Info

Channel Shape ID

Cause

The Channel Shape identified does not have any roughness values specified in its profile.

Advice

Check the profile of the Channel Shape.

E2629

You cannot mix zero and non-zero roughness values in a panel

Info

Channel Shape ID

Cause

In the Channel Profile grid of the Channel Shape object, there are a mixture of zero roughness values and non-zero roughness values in the same panel.

Advice

Check the roughness values in the Channel Profile grid of the Channel Shape object.

E2652

Roughness value is missing

Info

Channel shape ID

Cause

A roughness value is missing for the Channel profile for this channel shape.

Advice

Specify a value in the applicable Roughness Colebrook-White, Roughness Manning's or Roughness Manning's n field for the channel profile for this channel shape.

E2656

Blockage type 'Entry' must have exactly one outgoing link

Info

Downstream node ID

Cause

If the Blockage type is set to Entry, then the specified DS Node ID must only have one link connected to it.

Advice

Review the choices selected in the Blockage type and DS Node ID fields.

E2657

For blockage type 'Entry' the outgoing link must be a closed conduit

Info

Downstream node ID

Cause

If the Blockage type is set to Entry, then the link that is connected to the specified DS Node ID must be a closed conduit.

Advice

Ensure that the link connected to the specified DS Node ID field does not have one of the following shapes: open rectangle (OREC), open U (OU), open broad egg (OEGB), open narrow egg (OEGN), open trapezoidal (OTn:m, where n, m are integers), or User-defined with non-zero width at the soffit, or asymmetric shapes with non-equal left-hand side/right hand side values for height 1.0.

E2658

Blockage type 'Exit' must have exactly one incoming link

Info

Upstream node ID

Cause

If the Blockage type is set to Exit, then the specified US Node ID must only have one link connected to it.

Advice

Review the choices selected in the Blockage type and US Node ID fields.

E2659

For blockage type 'Exit' the incoming link must be a closed conduit

Info

Upstream node ID

Cause

If the Blockage type is set to Exit, then the link that is connected to the specified US Node ID must be a closed conduit.

Advice

Ensure that the link connected to the specified US Node ID field does not have one of the following shapes: open rectangle (OREC), open U (OU), open broad egg (OEGB), open narrow egg (OEGN), open trapezoidal (OTn:m, where n, m are integers), or User-defined with non-zero width at the soffit, or asymmetric shapes with non-equal left-hand side/right hand side values for height 1.0.

E2660

Must have at least one outgoing link

Info

Downstream node ID

Cause

The specified DS Node ID must have a minimum of one outgoing link connected to it.

Advice

Ensure that at least one outgoing link has been selected in the DS Node ID field.

E2661

Must have at least one incoming link

Info

Upstream node ID

Cause

The specified US Node ID must have a minimum of one incoming link connected to it.

Advice

Ensure that at least one incoming link has been selected in the US Node ID field.

E2662

Outgoing link <Link_ID> has invalid type. Must be a conduit, a channel or a river section.

Info

Downstream node ID

Cause

The specified DS Node ID is not connected to a conduit, channel or river section type of link.

Advice

Check that the required link is a conduit, channel or river section and that it is connected to the specified DS Node ID, or change the selection in the DS Node ID field.

E2663

Incoming link <Link_ID> has invalid type. Must be a conduit, a channel or a river section.

Info

Upstream node ID

Cause

The specified US Node ID is not connected to a conduit, channel or river section type of link.

Advice

Check that the required link is a conduit, channel or river section and that it is connected to the specified US Node ID, or change the selection in the US Node ID field.

E2676

Must correspond to field name in <tablename> table

Info

Damage Receptor ID

Cause

The selected Linked shapes reference field is not a field in the specified Linked shapes table.

Advice

Review the choices selected in the Linked shapes table and Linked shapes reference field fields.

E2677

Enclosing 2D zone has been re-meshed since 2D elements were last assigned

Info

Damage Receptor ID

Cause

The 2D zone in which the Damage Receptor is located has been remeshed since 2D elements were assigned.

Advice

Re-assign the 2D elements using the current 2D mesh.

E2678

No 2D elements have been assigned from enclosing 2D zone

Info

Damage Receptor ID

Cause

2D elements have not been assigned to the Damage Receptor.

Advice

Assign the 2D elements using the current 2D mesh.

E2679

Damage receptor position or associated polygon boundaries have changed since 2D elements were last assigned

Info

Damage Receptor ID

Cause

The Damage Receptor has been moved, or changes have been made to the associated polygon set. Polygon set changes may occur when:

  • Previously associated polygon deleted
  • Boundary of associated polygon edited
  • Associated polygon added
  • Previously associated polygon has had the value in its reference field changed

  • Damage receptor Linked shapes table value has been changed
  • Damage receptor Linked shapes reference field value has been changed
  • damage receptor Linked shapes reference value has been changed

Advice

Re-assign the 2D elements using the current Damage Receptor location and associated polygon set.

E2697

Overlaps with other Turbulence zone (2D) <number of overlapping zones>

Info

Turbulence Zone (2D)

Cause

The boundary of this Turbulence Zone (2D) overlaps with other Turbulence Zone (2D).

Advice

Check the geometry of the Turbulence Zone (2D).

E2702

No infiltration surface (2D) defined with this ID

Info

Infiltration Zone ID

Cause

Infiltration surface associated with the infiltration zone identified does not exist

Advice

Select an existing object from the Infiltration surface choice list

E2724

Overlaps with other Permeable zone (2D) <ID(s) of overlapping zone(s)>

Info

Permeable Zone ID

Cause

The boundary of the 2D permeable zone overlaps with other 2D permeable zones.

Advice

Check the geometry of the 2D permeable zones.

E2725

Must specify a set of lateral links to drain to

Info

Lateral links

Cause

The Drains to field is set to Multiple links but you have not specified any links in the Lateral links grid editor.

Advice

Click on the button, located in Lateral links field, to display the grid editor which you can use to specify which lateral links this zone is to drain to.

E2726

Not in Node set

Info

Node ID

Cause

The Drains to field is set to Node but you have not specified a node in the Node ID field.

Advice

Specify which node, in the Node ID field, that this zone is to drain to.

E2727

No subcatchment exists with this ID

Info

To Subcatchment ID

Cause

The Drains to field has been specified as a Subcatchment, but the subcatchment specified in the To subcatchment ID field does not exist in this network.

Advice

Check that the appropriate subcatchment that this zone is to drain to has been specified in the To subcatchment ID field, and change if necessary.

E2728

Non-existent link <link ID> specified to drain to

Info

Link suffix/lateral links

Cause

The Drains to field has been set to Link, but the link ID (formed by the specified Node ID and Link suffix fields) does not exist in the network.

Advice

Ensure that you have specified the correct link.

E2730

Permeable zone (2D)s cannot drain to outfalls

Info

Node ID

Cause

The Drains_to field is set to Node but the type of node specified in the Node ID field is an outfall type of node. A permeable zone (2D) can only drain to a manhole, storage, break or pond type of node.

Advice

Ensure that the node, specified in the Node ID field, is a manhole, storage, break or pond type of node.

E2733

Must be less than Initial infiltration

Info

Infiltration Surface (2D) ID

Cause

Applicable to Infiltration Surface (2D) with Infiltration Type = Horton

Limiting infiltration value > Initial infiltration value

Advice

Check the surface definition parameters of the reported Infiltration Surface.

E2751

Below attached node's lowest storage level

Info

River Reach ID

Cause

The River Reach is connected to a Storage or Pond node.

One or more vertices of the River section closest to the connecting node has a River elevation less than the lowest Level value in the Storage array of the node.

Advice

Check river section elevations and connecting node storage array levels.

E2763

Overlaps with other 2D IC zone <2D IC Zone ID>

Info

2D IC Zone

Cause

The 2D IC Zone identified overlaps with another 2D IC Zone.

Advice

Edit the boundaries of the 2D IC Zones to remove overlaps.

E2776

Below attached node's lowest storage level

Info

Bridge ID, DS link section data / US link section data

Cause

The Bridge is connected to a Storage or Pond node.

One or more vertices of the US/DS link section data adjacent to the connecting node has an Elevation less than the lowest Level value in the Storage array of the node.

Advice

Check bridge section elevations and connecting node storage array levels.

E2826

Chainage elevation table must contain at least two entries

Info

Irregular Weir ID

Cause

The Irregular Weir identified has only one entry in its Chainage elevation profile. A minimum of two entries are required.

Advice

Check the Chainage elevation profile of the Irregular Weir

E2854

Infinite crest level type invalid for weir

Info

Linear Structure (2D) ID

Cause

The Linear Structure identified has Structure type set to Weir and Crest level set to Infinite.

Advice

Review the Crest level setting of the linear structure.

E2855

Must enter crest level values for all section data points

Info

Linear Structure (2D) ID

Cause

The Linear Structure identified has Crest level set to Irregular and one or more Crest level values in the Section data is missing.

Advice

Review the Section data values of the linear structure.

E2861

RTC definition <RTC id> at offset covered by bridge/sluice linear structure (2D) <linear strucutre id>

Info

Base Linear Structure (2D) ID

Cause

The Base Linear Structure identified has RTC definition value set in the Section data editor at a vertex that coincides with a bridge/sluice linear structure vertex.

Advice

Review the RTC definition values of the linear structure.

E2870

Lower limit cannot exceed upper limit

Info

Mesh Level Zone ID

Cause

The value of the Lower limit level field of the Mesh Level Zone identified is greater than the value of the Upper limit level field.

Advice

Review the Lower limit level and Upper limit level values of the Mesh Level Zone.

E2881

Overlaps with sluice (2D) <sluice (2D) id> on base linear structure (2D) <base linear structure (2D) id>

Info

Sluice Linear Structure (2D) ID

Cause

The Sluice Linear Structure (2D) has Start length and Length values resulting in an overlap with another Sluice Linear Structure (2D) object associated with the identified base linear structure.

Advice

Review the Start length and Length values of the 2D sluice.

E2882

Overlaps boundary of 2D zone <2D zone id>

Info

Sluice Linear Structure (2D) ID

Cause

The Sluice Linear Structure (2D) has Start length and Length values resulting in an overlap with a 2D zone boundary.

Advice

Review the Start length and Length values of the 2D sluice.

E2885

Base linear structure (2D) crosses multiple 2D zone boundaries

Info

Base Linear Structure (2D) ID

Cause

The Base linear structure crosses more than one 2D zone boundary.

Advice

Create separate base linear structures for each 2D zone or merge 2D zones into one zone.

E2886

Head unit flow <head unit flow id> not present in network

Info

Base Linear Structure (2D) ID

Cause

A value has been specified in the Head unit flow table field of the Base linear structure, but a Head unit flow object of that name does not exist in the network.

Advice

Select an existing Head unit flow object or create a Head unit flow with ID set to value specified in Head unit flow table.

E2887

Overlaps base linear structure (2D) <base linear structure id>

Info

Base Linear Structure (2D) ID

Cause

The Base linear structure overlaps another base linear structure.

Advice

Join base linear structure objects or remove overlap.

E2888

Overlaps river reach <river reach id> left bank/right bank

Info

Base Linear Structure (2D) ID

Cause

The Base linear structure overlaps the left bank or right bank or a river reach.

Advice

Review location of base linear structure object.

E2902

Must reference a linear structure (2D)

Info

Sluice Linear Structure (2D) ID

Cause

A value has not been specified in the Base linear structure (2D) ID field of the Sluice Linear Structure (2D).

Advice

Enter a Base linear structure (2D) ID for the 2D sluice.

E2903

Referenced linear structure (2D) does not exist in network

Info

Sluice Linear Structure (2D) ID

Cause

The linear structure specified in the Base linear structure (2D) ID field of the Sluice Linear Structure (2D) does not exist in the network.

Advice

Enter a valid Base linear structure (2D) ID for the 2D sluice.

E2911

Completely outside 2D zone boundary

Info

Sluice Linear Structure (2D) ID

Cause

The Sluice Linear Structure (2D) has Start length and Length values resulting in the structure being outside of any 2D zone.

Advice

Review the Start length and Length values of the 2D sluice.

E7777

Illegal or missing roughness values. Error repeated <no. of errors> times

Info

Object ID, field name

Cause

Roughness values have not been specified.

Advice

Enter roughness values.

E7778

Opening doesn't exist in bridge openings table, or left and right sides are reversed

Info

Bridge ID, bridge section

Cause

An opening has been defined in the bridge section data but the opening object does not exist or the sides have been specified the wrong way round.

Advice

Review data entered in the Opening and Side fields of the section editor.

E7780

Distance between opening left and right sides on section (after projection) must be at least the opening width

Info

Bridge ID, bridge section

Cause

The distance between left and right opening markers is less than the width of the opening associated with the bridge.

When the Skew openings and piers field of the bridge is unchecked, the width checked is the projected width of the opening.

Advice

Rebuild bridge openings.

E7780

Chainage of section <section id> is not at least 1 mm greater than preceding section

Info

River Reach ID, river section

Cause

The distance between the identified river section and the next upstream section at the point at which the sections intersect the river reach link is less than 1 mm.

Advice

Rebuild reach sections.

E7780

Bridge section and deck have different numbers of openings

Info

Bridge ID, bridge section

Cause

A different number of openings has been defined in the US bridge section data/DS bridge section data editor and the Bridge deck data editor.

Advice

Review opening data in the bridge section editors.

E7780

Section XXX does not cross the bridge link

Info

Bridge ID, bridge section

Cause

The section, indicated by XXX in the message, does not cross the bridge link (i.e. the centre line of the bridge) but it should.

Advice

Review the data in the bridge section editor, or inspect on the GeoPlan, and ensure that the offending section crosses the bridge link.

E7780

u/s bed is at or above soffit of opening / d/s bed is at or above soffit of opening

Info

Bridge ID

Cause

There are points on the bridge's US bridge section data or DS bridge section data whose levels are above its opening soffit (i.e the bridge opening's Height + US invert level or DS invert level) but they must be below it.

Advice

Ensure that all points on the bridge's US bridge section data or DS bridge section data are below the bridge opening's Height + US invert level or DS invert level.

E7780

No openings specified

Info

Bridge ID, bridge section

Cause

An bridge opening has been specified for a bridge in its US bridge section data or DS bridge section data but no bridge opening with that ID has been defined.

Advice

Check that the ID specified in the Opening field of the bridge’s US bridge section data or DS bridge section data is correct. If it is the correct ID, then ensure that a bridge opening with the specified ID is defined.

E7780

Bridge section and deck have different openings

Info

Bridge ID, bridge section

Cause

The bridge opening ID that has been specified in the US bridge section data or US bridge section data editor is different to the ID specified in its corresponding Bridge deck data editor, and they should be the same.

Advice

Review opening data in the bridge section editors.

E7781

d/s bed is at or above soffit of opening near left/right ends. Try inserting openings into bridge sections.

Info

Bridge ID

Cause

There are points on the bridge's US bridge section data or DS bridge section data whose levels are above its opening soffit (i.e the bridge opening's Height + US invert level or DS invert level) but only in the vicinity of the openings left/right ends.

These points need to be between the left/right side of the opening but more than 0.5 *Width from the mid-point of the opening.

Advice

Use the BridgeInsert selected openings into sections option from the Model menu to reposition the opening's left/right ends so that these points are outside the opening. See the Bridges topic for further information about using this menu option.

E7782

River reaches may not be connected to manholes

Info

River Reach ID

Cause

The us node or ds node of a River Reach is a node of type manhole.

Advice

Connect the River Reach to a node of type other than manhole.

E7783

River reach must contain at least two sections

Info

River Reach ID

Cause

The River Reach identified is made up of less than two sections.

Advice

Add more sections to the River Reach

E7785

FHWA is not valid as a US/DS headloss type for a channel, river reach or bridge

Info

River Reach / Bridge ID

Cause

The US/DS headloss type field of the River Reach or Bridge has been set to FHWA.

(FHWA headloss condition is only valid for closed conduits.)

Advice

Review the US headloss type / DS headloss type values.

E7788

Missing bank for bank connection

Info

River Reach ID

Cause

A bank connection has been specified, but there is no bank section data defined.

Advice

Define bank section data.

E7793

Bank section marker <section marker id> not found in river reach sections

Info

River Reach ID, Left river bank/Right river bank

Cause

The Section marker ID specified in the Left river bank or Right river bank editor of the River Reach does not correspond to the ID of any of the River Sections defined in the River Sections editor of the reach

Advice

Check the Section marker values in the Left/Right river bank editor

E7794

Bank section marker <section marker id> is either, not in order or non-continuous

Info

River Reach ID, Left river bank/Right river bank

Cause

The Section marker IDs specified in the Left river bank or Right river bank editor of the River Reach are not in the same order as the River Sections defined in the River Sections editor of the reach.

Section markers must be specified in the same order as River sections and must not skip River sections.

Advice

Check the Section marker values in the Left/Right river bank editor.

E7798

Bank connection for 2D zone has no overlap between bank and 2D mesh. There will be no overbank flow

Info

River Reach ID

Cause

A 2D zone bank connection has been specified, but the corresponding bank section does not overlap the 2D mesh.

Advice

Review bank and 2D zone geometry.

E7803

Bank connection for 2D zone is invalid. Bank geometry between vertices <vertex 1> and <vertex 2> incompatible with 2D mesh

Info

River Reach ID, Left river bank/Right river bank

Cause

River reach bank geometry is not compatible with connected 2D mesh geometry.

Advice

Review bank geometry data and re-mesh connected 2D zone.

E7808

A value must be specified for the discharge coeff- cd. Error repeated <x> times

Info

River Reach ID/Inline Bank ID, Left river bank/Right river bank

Cause

There are x number of Discharge coeff - cd fields that have no value specified in one of the following:

  • Left river bank or Right river bank editor of the River Reach
  • Section data editor of an Inline bank

A Discharge coeff- cd must be specified for all bank vertices.

Advice

Enter Discharge coeff - cd values for the bank.

An SQL query can be used to set multiple values e.g.

set left_bank.discharge_coeff = 0.9 where left_bank.discharge_coeff = NULL;

set right_bank.discharge_coeff = 0.9 where right_bank.discharge_coeff = NULL

E7809

A value must be specified for the modular limit. Error repeated <x> times

Info

River Reach/Inline Bank ID, Left river bank/Right river bank

Cause

There are x number of Modular limit fields that have no value specified in one of the following:

  • Left river bank or Right river bank editor of a River Reach
  • Section data editor of an Inline bank

A Modular limit must be specified for all bank vertices.

Advice

Enter Modular limit values for the bank.

An SQL query can be used to set multiple values.

The example query below uses example modular limit values for river reach banks. Replace these with suitable values for the river reach(es) to be updated.

set left_bank.modular_ratio = 0.7 where left_bank.modular_ratio = NULL; set right_bank.modular_ratio = 0.8 where right_bank.modular_ratio = NULL

E7811

Zero and non-zero manning values mixed within a panel on section <section ID> at point <point number>

Info

River Reach ID, section ID, section row number

Cause

In the River Sections Editor of the River Reach, there are a mixture of zero roughness values and non-zero roughness values within the same panel for the identified section at the identified point.

Within each panel, all values must either be zero (representing a panel that stores but does not convey flow), or all zero (representing a conveying panel).

Advice

Check the roughness values in the River Sections editor of the River Reach object.

E7813

Section <section ID> contains no panels with a non-zero manning value

Info

River Reach ID, section ID

Cause

In the River Sections Editor of the River Reach, all Roughness Manning's n values are set to zero for the identified section.

A panel with all roughness values set to zero represents a panel that stores but does not convey flow. There must be at least one conveying panel (non-zero roughness values) on a section.

Advice

Check the roughness values in the River Sections editor of the River Reach object.

E7815

Not referenced in sections of related bridge <bridge id>

Info

Bridge opening ID, bridge ID

Cause

The bridge opening is not defined in the bridge sections of the bridge identified by the Bridge US node ID and Bridge link suffix fields of the opening.

The opening may have been added, but not yet inserted into the bridge sections.

Advice

Insert the opening into related bridge sections.

E7817

Roughness values have a mix of zero and non zero in a panel

Info

Bridge ID, bridge section

Cause

In the bridge section, there are a mixture of zero roughness values and non-zero roughness values in the same panel.

Advice

Review section roughness data.

E7822

Sediment grading not found in list

Info

Bridge/River Reach ID, sediment grading field

Cause

The Sediment Grading specified in the sediment grading field does not exist in the network.

Advice

Select an existing Sediment Grading or create a new user defined grading.

E7823

'Limit erosion by' must be an option that includes Depth

Info

Bridge/River Reach ID

Cause

Limit erosion by is set to Level or Unlimited and Bed updating is set to Invert.

Limit erosion by must be set to Depth or Depth and Level when Bed updating set to Invert.

Advice

Review Limit erosion by and Bed updating settings.

E7824

Erosion depth limit must be zero

Info

Bridge/River Reach ID

Cause

Bed updating is set to Invert but Erosion depth limit is not set to zero or null.

Advice

Review Erosion depth limit and Bed updating settings.

E7825

<Column name Row number> in the user-defined conveyance curve for section <name> not defined

Info

River Reach, Conveyance data field

Cause

The depth or conveyance for a given row of a section is not defined in the user-defined conveyance table

Advice

Specify the missing depth or conveyance in the user-defined conveyance table

E7826

<Column name Row number> in the user-defined conveyance curve for section <name> must not be lower than previous value

Info

River Reach, Conveyance data field

Cause

The value for an area, width or perimeter entry in the user-defined conveyance table is lower than that in the previous line. A value may be unchanged in comparison to the previous one, it just may not decrease.

Advice

Change the value for the applicable area, width or perimeter in the user-defined conveyance table.

E7827

Area, Width and Perimeter for section <name> must either be all null or all defined

Info

River Reach, Conveyance data field

Cause

If a conveyance table has any entry with area, width or perimeter defined, every entry in that row must have an area, width and perimeter defined.

Advice

Ensure that there is an entry, even if it is 0, in every area, width or perimeter for every row that has an area, width or perimeter defined in the user-defined conveyance table

E9000

A value must be specified for this field

Info

Object ID, field name

Cause

A value has not been entered in a required field.

Advice

Enter a value in the reported field.

E9001

Value too small. Minimum value is <minimum value>

Info

Object Type. Object name. Field name. Minimum acceptable value

Cause

The value in the field indicated by the error message is less than the minimum acceptable value.

Advice

Enter a valid value in this field

E9001

Value too large. Maximum value is <maximum value>

Info

Object Type. Object name. Field name. Maximum acceptable value

Cause

The maximum acceptable value in the field indicated by the error message has been exceeded.

Advice

Enter a valid value in this field.

E9001

Invalid value. Value should be less than <value>

Info

Object Type. Object name. Field name. Value.

Cause

The value specified in the field indicated in the error message must be less than the value indicated in the error message.

Advice

Enter a valid value in this field.

E9002

<field><(index)> Value too small. Minimum value is <minimum value>

Info

Object Type. Object name. Field name. Field entry index. Minimum acceptable value

Cause

The value in the field indicated by the error message is less than the minimum acceptable value

Advice

Enter a valid value in this field

E9003

<field> Value is not one of the permitted values of <field options>

Info

Object Type. Object name. Field name. Field value

Cause

The value in the field indicated by the error message is not one of the valid options.

Advice

Select another option for this field.

E10553

Bank geometry incompatible with 2D mesh

Info

River Reach ID, Left river bank/Right river bank

Cause

Unable to match river/inline bank points with vertices in 2D mesh belonging to 2D Zone associated with bank via overbank flow.

Advice

Review bank geometry data and re-mesh connected 2D zone.

E11300

A value must be specified for this field

Info

Subcatchment

Cause

The Drain to field has been specified as either a Node, Link or Subcatchment but a value has not been specified in either the Node ID, Link suffix or To subcatchment ID fields.

Advice

Enter a valid value in the appropriate field.

E11550

A value must be specified for this field

Info

Permeable Zone 2D

Cause

The Drains to field has been specified as either a Node, Link, Subcatchment or Multiple links, but a value has not been specified in either the Node ID, Link suffix, To subcatchment ID, or Lateral links fields.

Advice

Enter a valid value in the appropriate field. A link requires that a value is specified in the Node ID and Link suffix fields.

E22101

Element <element ID> : <Land use ID> not found in land use table

Info

Subcatchment ID

Cause

The land use, whose name is indicated in the message, is not currently defined.

Advice

Either define the land use or select a different option in the Subcatchment's Land uses field.

E22101

Drainage system has no acceptable outlet nodes

Info

Cause

The SWMM network does not contain any Outfall type of nodes but a minimum of one is required for dynamic flow routing.

Advice

Ensure that at least one Node type is set to Outfall.

E22102

Element <element ID> : Entry for Land use <Land use ID> already present

Info

Subcatchment ID

Cause

The land use, whose name is indicated in the message, has been specified more than once for this subcatchment. Each type of land use may only be used once for each subcatchment.

Advice

Either delete this type of land use from the Subcatchment's Land uses field, or select a different land use.

E22103

Element <element ID> : <pollutant_name> not found in pollutant table

Info

Subcatchment ID

Cause

The pollutant, whose name is indicated in the message, is not currently defined.

Advice

Either define the pollutant or select a different pollutant for the subcatchment in the Initial buildup field.
E22104

Element <element ID> : Entry for pollutant <pollutant_name> already present

Info

Subcatchment ID

Cause

The pollutant, whose name is indicated in the message, is defined more than once.

Advice

Either select a different pollutant for the subcatchment in the Initial buildup field, or delete the duplicate pollutant or change its name.

E22106

Element <element_ID>: No type specified for LID <LID_Control_ID>

Info

Subcatchment ID

Cause

No type of LID control has been specified for a LID control structure that is associated with this subcatchment.

Advice

Ensure that the Control type is specified for the applicable LID control structure in the LID control properties.

E22107

Element <element_ID>: LID area exceeds total area for Subcatchment <Subcatchment_ID>

Info

Subcatchment ID

Cause

The area specified for a LID control structure cannot be greater than the area specified for the subcatchment it is associated with.

Advice

Check the value specified in the applicable subcatchment's Area parameter and ensure that it is greater than the value specified for the Area parameter for the LID control.

E22208

Duplicate objects with outlet ID name

Info

Subcatchment ID

Cause

The name assigned to the Receiving node is used for both a node and a subcatchment in the network.

Advice

Check the name specified in the subcatchment’s Receiving node property, and change as required. If the name of the Receiving node is correct, then check the names of all subcatchments in the network and ensure that none of the subcatchments have the same name as the Receiving node.

E22210

Elevation is below Aquifer Initial ground water elevation for Subcatchment

Info

Subcatchment ID

Cause

The value assigned to a subcatchment’s groundwater Elevation parameter cannot be less than the value assigned to the intial ground water elevation of the aquifer associated with the subcatchment.

Advice

Check the values specified in the subcatchment’s Elevation and Aquifer initial ground water elevation properties, and change as required. If no value is specified for Aquifer initial ground water elevation in the subcatchment's properties, then check the Elevation value set in the Aquifer's properties, and ensure that it is less than the value specified for the subcatchment's Elevation.

E22111

<Curve ID> not found in the underdrain curve table

Info

Subcatchment ID

Cause

A LID control of the type Permeable pavement, Bio-retention, Infiltration trench or Rain barrel has been selected for this subcatchment, but the underdrain curve specified for it does not exist in the database.

Advice

Check that the correct type of LID control has been specified, and change if not. Or, if the LID control type is correct, then either add the applicable underdrain curve or choose a different underdrain curve for the LID control.

E22112

Element <element_ID>: Assigned node not found

Info

Subcatchment ID

Cause

A node has been specified in the Drain to node field of the LIDs control structure that is associated with this subcatchment, but this node does not exist.

Advice

Check that the applicable node is specified in the Drain to node field of the LIDs control structure properties. If the correct node has been specified, then check that it has been added to the relevant network.

E22113

Element <element_ID>: Assigned subcatchment not found

Info

Subcatchment ID

Cause

A subcatchment has been specified in the Drain to subcatchment field of the LIDs control structure that is associated with this subcatchment, but the specified subcatchment does not exist.

Advice

Check that the applicable subcatchment is specified in the Drain to subcatchment field of the LIDs control structure properties. If the correct subcatchment has been specified, then check that it has been added to the relevant network.

E22151

Element <element ID> : Node treatment pollutant <pollutant_name> is undefined

Info

Node ID

Cause

The pollutant (<pollutant name>) is not currently defined.

Advice

Either define the pollutant or select a different pollutant in the Pollutant column in the grid of the Node Treatment field.
E22152

Element <element ID> : Node treatment expression is undefined

Info

Node ID

Cause

An expression is missing from the Fraction field.

Advice

Enter an expression in the Fraction column in the grid of the Node Treatment field.
E22153

Element <element ID> : Node treatment pollutant <pollutant_name> is a duplicate

Info

Node ID

Cause

The pollutant (<pollutant name>) has already been used for this node.

Advice

Only one treatment fraction for effluent concentration or for fractional removal can be applied to a selected pollutant for a particular node. Either select a different pollutant to apply the fraction to or check that the correct result type has been specified. See the Node Treatment field for further information.
E22154

Node <Node_ID> has initial water depth greater than maximum depth

Info

Node ID

Cause

A node cannot have an initial water depth that is greater than its specified maximum depth.

Advice

Check the value specified in the node's Initial water depth parameter and ensure that it is less than the value specified in its Max depth parameter.

E22213

The sum of the soil area should be less than or equal to 100%

Info

Subcatchment ID

Cause

The total % area of all soils assigned to this subcatchment cannot be greater than 100.

Advice

Check that the total of the % areas for all soils, specified in the Soils grid, is less than or equal to 100.

E22214

Width cannot be less than or equal to 0

Info

Subcatchment ID

Cause

The width of a subcatchment is less than 0. But it must be greater than or equal to 0.

Advice

Check the specified Subcatchment width and ensure that it is equal to or greater than 0.

E22215

Outlet is not of type (sw_node/sw_subcatchment) as specified by the Drains to field

Info

Subcatchment ID

Cause

A subcatchment's Drains to field has either been set to sw_node but a node has not been selected in the Outlet field, or it has been set to sw_subcatchment but a subcatchment has not been selected in the Outlet field.

Advice

Ensure that a node name has been selected in the Outlet field if the Drains to field is set to sw_node. Or, if the Drains to field is set to sw_subcatchment, ensure that a name of a subcatchment has been selected in the Outlet field.

E22216

Referenced Rain gage ID does not exist

Info

Subcatchment ID

Cause

The name or identifier of the Rain Gage associated with this subcatchment does not exist.

Advice

Check the name of the rain gage specified in the subcatchment's Rain gage property. If it is correct, then ensure that rain gage with that name has been defined.

E22218

Drying time should not be less than 0 when using an SCS runoff model type

Info

Subcatchment ID

Cause

The Runoff model type is set to either SCS_curvilinear or SCS_triangular. Both these runoff models use a Curve number type of Infiltration model which requires a drying time to be specified, and this drying time must be equal to or greater than zero.

Advice

Specify a value equal to or greater than 0 in the Drying time field for the subcatchment.

E22219

Infiltration should be 'Curve number' when using an SCS runoff model type

Info

Subcatchment ID

Cause

The Runoff model type is set to either SCS_curvilinear or SCS_triangular. These types of runoff models must be used with an Infiltration model set to Curve_number.

Advice

Review the choice of Infiltration model or Runoff model type for the subcatchment.

E22312

Max depth cannot be null or empty

Info

Node ID

Cause

No maximum depth or a maximum depth of 0 has been specified for the node.

Advice

Ensure that a non-zero value is specified in the Max depth field for this node.

E22313

Max depth cannot be less than 0

Info

Node ID

Cause

A negative value has been specified as the maximum depth for this node but this is not allowed.

Advice

Check the specified Max depth value and ensure that it is greater than zero.

If the system default flag (#D) has been set on the Max depth field for this node, ICM automatically calculates the Max depth as the Ground level minus the Invert elevation which may have resulted in a negative maximum depth. Therefore check the values in the Ground level and Invert elevation fields, and change as required.

If you do not want ICM to calculate the maximum depth, remove the #D flag from the Max depth property and ensure that the specified Max depth value is greater than zero.

E22314

This junction (flood type '2D') is not contained within a 2D zone

Info

Node ID

Cause

The 2D node is not within a 2D Zone.

2D nodes are nodes whose Type is set to Junction and Flood Type is set to 2D.

Advice

Add a 2D Zone that includes the 2D node within its boundary.

E22315

This junction (flood type '2D') is not contained within a 2D zone mesh element

Info

Node ID

Cause

A 2D node is within a 2D Zone, but not within a mesh element.

2D nodes are nodes whose Type is set to Junction and Flood Type is set to 2D.

Advice

The 2D node may be within a void in the 2D mesh.

Check that the node location is as expected.

Check that the objects or file used to define voids are as expected.

E22460

Rainfall polygon TVD connectors are applied spatially and so should not have a connected object type

Info

TVD Connector ID

Cause

A Connected object type has been specified for a TVD connector but one is not required for this type of TVD connector.

Advice

Check that you are viewing the properties of the correct TVD connector and, if you are, ensure that the Connected object type field is not set.

E22466

TVD connector with level units must connect to an Outfall node with type Timeseries

Info

TVD Connector ID

Cause

The selected Output units type for the TVD connector is Z but the Connected object type is not an outfall type of node with an Outfall type set to Timeseries. Only this type of node can be connected to a TVD connector with Output units set to Z.

Advice

Check the properties of the node (selected in the TVD connector's Connected object type field) and ensure that its Node type is set to Outfall, and its Outfall type is set to Timeseries.

If the correct node has been specified in the TVD connector's Connected object type field, change the type of Output units to a value other than Z.

E22467

TVD connector with pollutant mass flow or concentration units must connect to a node

Info

TVD Connector ID

Cause

The Output units for the TVD connector have been set to MFU or MCU but the Connected object type is not set to Node. A TVD connector can only be connected to a node when the Output units are set to MFU or MCU.

Advice

Ensure that the Connected object type field is set to Node or, if the specified Connected object type is correct, change the Output units to a type other than MFU or MCU.

E22468

TVD connector with undefined pollutant

Info

TVD Connector ID

Cause

The Output units for the TVD connector have been set to MFU or MCU and the Connected object type is set to Node but a pollutant has not been selected in the Input attribute field.

Advice

Ensure that a node is selected in the Connected object id field and that you choose which pollutant provides the input to the selected node in the Input attribute field.

E22950

Invalid cross section for Link

Info

Link ID

Cause

Either an invalid shape or invalid set of dimensions was specified for a conduit with an irregular or custom type of shape.

Advice

Either check the specified transect or conduit shape, and change as required, or change the selected type of Shape.

E22951

Invalid value. Value must be greater than 0

Info

Link ID

Cause

The length of a conduit must be greater than 0.

Advice

Check the specified conduit Length and ensure that it is greater than 0.

E22952

Invalid value. Value must be greater than 0

Info

Link ID

Cause

The width of a conduit must be greater than 0.

Advice

Check the specified conduit Width and ensure that it is greater than 0.

E23050

Missing or invalid pump curve assigned to Pump

Info

Pump ID

Cause

No pump curve or an invalid type of pump curve has been specified for the pump.

Advice

There are four different types of pump curves so ensure that the name of the correct pump curve type has been specified in the Pump curve ID field, or if this pump is meant to be an ideal pump, add a check in the Ideal pump check box.

E23051

Multiple ideal pumps have the same node connections

Info

Pump ID

Cause

More than one ideal pump is connected to the same start and end nodes. Only one ideal pump can be connected between the same start and end nodes.

Advice

Remove the check from the Ideal pump check box for the additional pumps that are connected between the same start and end nodes, or ensure that the additional ideal pumps are located between different start and end nodes.

E23104

Roof height cannot be null or zero

Info

Weir ID

Cause

No roof height or a roof height of 0 has been specified for the weir.

Advice

Ensure that a Roof height is specified for this weir and that the height is greater than 0. If the weir being modelled does not have a roof, then ensure that the specified value is higher than the water could possibly reach.

E23301

Transect profile must have two or more points defined

Info

Transect ID

Cause

The transect profile has only one or no points specified for it.

Advice

Ensure that two consecutive rows in the transect profile grid contain a point (a Station and its corresponding Elevation), and that Station values are specified in ascending order.
E23302

Element <element ID> : This element in the transect profile has no data for '<Field name>'

Info

Transect ID

Cause

No value has been specified in the identified field.

Advice

Ensure that a value is specified for both a Station and its corresponding Elevation field on each grid row in the transect profile, and that Station values are specified in ascending order.
E23303

Element <element ID> : The 'Station' value of this element must be greater than or equal to the previous one

Info

Transect ID

Cause

The Station values in the transect profile must be specified in ascending order. The value, specified in the row indicated in the <element ID>, is less than the value specified for the Station in the preceding row.

Advice

Check the values in the transect profile and ensure that they are specified in ascending order.
E23401

Element <element ID> : <pollutant_name> not found in pollutant table

Info

Landuse ID

Cause

The pollutant, whose name is indicated in the message, is not currently defined.

Advice

Either define the pollutant or select a different pollutant in the Landuse Build-up field.
E23402

Element <element ID> : Entry for pollutant <pollutant_name> already present

Info

Landuse ID

Cause

The pollutant, whose name is indicated in the message, is defined more than once.

Advice

Either select a different pollutant in the Landuse Build-up field, or delete the duplicate pollutant or change its name.

E23403

Element <element ID> : <pollutant_name> not found in pollutant table

Info

Landuse ID

Cause

The pollutant, whose name is indicated in the message, is not currently defined.

Advice

Either define the pollutant or select a different pollutant in the Landuse Washoff field.
E23404

Element <element ID> : Entry for pollutant <pollutant_name> already present

Info

Landuse ID

Cause

The pollutant, whose name is indicated in the message, is defined more than once.

Advice

Either select a different pollutant in the Landuse Washoff field, delete the duplicate pollutant or change its name.

E23501

The sum of all response ratios (Short/ Medium /Long Term) cannot be greater than 1.0

Info

Unit Hydrograph ID

Cause

The values specified in the Response ratio R - short term, Response ratio R - medium term and Response ratio R - long term for a Unit Hydrograph add up to more than 1. The sum of all three response ratios must not be greater than 1.

Advice

Ensure that the sum of the values specified in the applicable Unit Hydrograph's response ratios fields do not exceed a total of 1.0.

E23523

Transect has too few stations

Info

Transect ID

Cause

The minimum number of stations that can be specified for a transect's cross section channel profile is 2.

Advice

Ensure that at least 2 Station values have been specified for the applicable transect's profile.

E23525

Transect has too many stations

Info

Transect ID

Cause

The maximum number of stations that can be specified for a transect's cross section channel profile is 1500.

Advice

Ensure that less than 1500 Station values have been specified for the applicable transect's profile.

E23527

Transect has no Manning's N

Info

Transect ID

Cause

No Manning's N roughness value has been specified for transect's right bank, left bank and/or channel properties.

Advice

Ensure that a Manning's N roughness value is specified in the transect's Left bank roughness and Right bank roughness and Channel roughness parameters.

E23529

Transect has invalid overbank locations

Info

Transect ID

Cause

The value specified for the offset at the start of a transect's right bank and/or the end of its left bank are not specified as the first and/or last station in its cross section channel profile.

Advice

Check the values specified in the transect's Left bank offfset and/or Right bank offset properties with the first and/or last Station values specified for its profile, and change as required.

E23531

Transect has no depth

Info

Transect ID

Cause

The same elevation has been specified for the transect's cross section channel profile, therefore the profile has no 'depth'.

Advice

Ensure that at least 2 different Elevation values are specified for the applicable transect's profile.

E23550

ID contains invalid characters (" ")

Info

Control curve ID

Cause

A space has been included in the name of the control curve but spaces are not allowed. Only letters, numbers and underscore characters can be used in a control curve ID.

Advice

Remove the space from the name specified in the Curve ID field or replace with a valid character.

E23650

ID contains invalid characters (" ")

Info

Pump curve ID

Cause

A space has been included in the name of the pump curve but spaces are not allowed. Only letters, numbers and underscore characters can be used in a pump curve ID.

Advice

Remove the space from the name specified in the Curve ID field or replace with a valid character.

E23700

ID contains invalid characters (" ")

Info

Rating curve ID

Cause

A space has been included in the name of the rating curve but spaces are not allowed. Only letters, numbers and underscore characters can be used in a rating curve ID.

Advice

Remove the space from the name specified in the Rating curve ID field or replace with a valid character.

E23750

ID contains invalid characters (" ")

Info

Shape curve ID

Cause

A space has been included in the name of the shape curve but spaces are not allowed. Only letters, numbers and underscore characters can be used in a shape curve ID.

Advice

Remove the space from the name specified in the Curve ID field or replace with a valid character.

E23800

ID contains invalid characters (" ")

Info

Tidal curve ID

Cause

A space has been included in the name of the tidal curve but spaces are not allowed. Only letters, numbers and underscore characters can be used in a tidal curve ID.

Advice

Remove the space from the name specified in the Tidal curve ID field or replace with a valid character.

E23850

ID contains invalid characters (" ")

Info

Storage curve ID

Cause

A space has been included in the name of the storage curve but spaces are not allowed. Only letters, numbers and underscore characters can be used in a storage curve ID.

Advice

Remove the space from the name specified in the Curve ID field or replace with a valid character.

E23858

Curve <Shape curve ID> has its data out of sequence. Unable to create

Info

Shape curve ID

Cause

The X values of the points specified for the applicable shape curve in the Shape Curve Editor are not in the correct sequence. The X values of a curve object must be entered in increasing order.

Advice

Check the X values for the applicable curve and change as required.

E23901

The soil field capacity is greater than or equal to the soil porosity

Info

Aquifier ID

Cause

The value specified for an aquifier's Soil field capacity cannot be greater than, or the same as, the value specified for its Soil porosity.

Advice

Check the specified values and ensure that the Soil field capacity value is less than the Soil porosity value.

E23902

The soil wilting point is greater than or equal to the soil field capacity

Info

Aquifier ID

Cause

The value specified for an aquifier's Soil wilting point cannot be greater than, or the same as, the value specified for its Soil field capacity.

Advice

Check the specified values and ensure that the Soil wilting point value is less than the Soil field capacity value.

E23903

The initial groundwater elevation is less than the elevation

Info

Aquifier ID

Cause

The value specified for an aquifier's groundwater elevation is less than the value specified for the elevation at the bottom of the aquifer.

Advice

Check the specified values and ensure that the Initial groundwater value is more than the Elevation value.

E23904

The initial moisture content is greater than the soil porosity

Info

Aquifier ID

Cause

The value specified for an aquifier's Initial moisture content is greater than the value specified for its Soil porosity.

Advice

Check the specified values and ensure that the Initial moisture content value is less than the Soil porosity value.

E23905

The initial moisture content is less than the soil wilting point

Info

Aquifier ID

Cause

The value specified for an aquifier's Initial moisture content is less than the value specified for its Soil wilting point.

Advice

Check the specified values and ensure that the Initial moisture content value is more than the Soil wilting point value.

E23906

Cannot be less than or equal to 0

Info

Object type. Object name. Field name.

Cause

The minimum acceptable value in the field indicated by the error message must be greater than 0.

Advice

Enter a valid value in this field.

E23955

Element <element_ID>: 'Pollutant name' not found in the pollutant table

Info

LID Control ID

Cause

A pollutant has been specified in the Underdrain pollutant removal grid for a LID control but the specified pollutant is not defined in the database.

Advice

Either define the pollutant whose name is indicated in the message or select a different pollutant in the grid.

E23956

Element <element_ID>: Entry for pollutant 'Pollutant name' already present

Info

LID Control ID

Cause

The same pollutant has been specified more than once in the Underdrain pollutant removal grid for a LID control.

Advice

Ensure that there is only one entry in the grid for the pollutant whose name is indicated in the message.

E23963

Storage curve's final area should not converge to zero

Info

Storage curve ID

Cause

The Depth and Surface area values defined in the Storage array field for this storage curve would result in a storage volume of less than zero for the node associated with the curve.

Advice

Check the specified Depth and Surface area values for the storage curve and change as necessary. If these are correct, then check the node's Max depth value.

E24150

ID contains invalid characters (" ")

Info

Weir curve ID

Cause

A space has been included in the name of the weir curve but spaces are not allowed. Only letters, numbers and underscore characters can be used in a weir curve ID.

Advice

Remove the space from the name specified in the Weir curve ID field or replace with a valid character.

E24200

ID contains invalid characters (" ")

Info

Underdrain curve ID

Cause

A space has been included in the name of the underdrain curve but spaces are not allowed. Only letters, numbers and underscore characters can be used in an underdrain curve ID.

Advice

Remove the space from the name specified in the Curve ID field or replace with a valid character.

E24202

No data for underdrain curve

Info

Underdrain curve ID

Cause

An underdrain curve has been selected for a LID control but no values have been specified for the curve.

Advice

Either specify the values for the underdrain curve identified in the message, or check that the correct curve has been selected for the LID control.

E24308

Curve <curve ID> has its data out of sequence. Unable to create

Info

Control/Pump/Rating/Tidal/Underdrain/Weir control curve ID

Cause

The X values of the points specified for the applicable curve in the Curve Editor are not in the correct sequence. The X values of a curve object must be entered in increasing order.

Advice

Check the X values for the applicable curve and change as required.

E24330

Boundary of 2D zone has changed since meshing was performed

Info

2D Zone ID

Cause

The 2D Zone boundary was edited after the current 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current polygon boundary.

E24331

Maximum triangle area has changed since meshing was performed

Info

2D Zone ID

Cause

The value in the Maximum Triangle Area field of the 2D Zone is different to the area value used to create the current mesh.

Advice

Either reset the Maximum Triangle Area of the 2D Zone to the value used when the current mesh was created, or re-mesh the 2D Zone using the current Maximum Triangle Area value.

E24332

Minimum angle has changed since meshing was performed

Info

2D Zone ID

Cause

The value in the Minimum Angle field of the 2D Zone is different to the minimum angle value used to create the current mesh.

Advice

Either reset the Minimum Angle of the 2D Zone to the value used when the current mesh was created, or re-mesh the 2D Zone using the current Minimum Angle value.

E24338

Polygons belonging to voids category <category id> have changed since meshing was performed

Info

2D Zone ID, Polygon Category ID

Cause

The boundary of a Polygon object(s) belonging to the Polygon's Category used to identify voids at the time of creating the current 2D mesh, was edited after the mesh was created.

This includes edits to polygons in the voids category that do not intersect the 2D Zone.

(Where voids have been derived from a file or layer, changes to the file or layer are not validated.)

Advice

Re-mesh the 2D Zone using the current Polygon set.

E24339

Lines belonging to break lines category <category id> have changed since meshing was performed

Info

2D Zone ID, Line Category ID

Cause

The geometry of a Line(s) belonging to the line Category used to identify Break Lines at the time of creating the current 2D mesh, was edited after the mesh was created.

This includes edits to Lines in the Break Lines category that do not intersect the 2D Zone.

(Where Break Lines have been derived from a file or layer, changes to the file or layer are not validated.)

Advice

Re-mesh the 2D Zone using the current Line set.

E24340

Lines belonging to walls category <category id> have changed since meshing was performed

Info

2D Zone ID, Line Category ID

Cause

The geometry of a Line(s) belonging to the line Category used to identify Walls at the time of creating the current 2D mesh, was edited after the mesh was created.

This includes edits to Lines in the Walls category that do not intersect the 2D Zone.

(Where Walls have been derived from a file or layer, changes to the file or layer are not validated.)

Advice

Re-mesh the 2D Zone using the current Line set.

E24355

Mesh has not been created for 2D zone

Info

2D Zone ID

Cause

A 2D mesh has not been generated for the 2D Zone

Advice

Generate a mesh for the 2D Zone

E24384

Subcatchment <subcatchment id> has been deleted/renamed since meshing was performed

Info

2D Zone ID, Subcatchment ID

Cause

The Subcatchment identified was used to create the current mesh in the 2D Zone, but no longer exists.

Subcatchments are only used to create a mesh when the 2D Zone option Apply rainfall etc directly to mesh elements is selected and the Apply rainfall etc option is set to outside subcatchments .

This error may be caused as a result of renaming of the Subcatchment.

Advice

Re-mesh the 2D Zone using the current set of subcatchments.

Alternatively, if the Subcatchment was renamed, reset the Subcatchment ID to the value used when the 2D mesh was created.

E24385

Subcatchment <subcatchment id> has had its boundary changed since meshing was performed

Info

2D Zone ID, Subcatchment ID

Cause

The boundary of a Subcatchment used to create the 2D Zone mesh was edited after the 2D mesh was created.

Subcatchments are only used to create a mesh when the 2D Zone option Apply rainfall etc directly to mesh elements is selected and the Apply rainfall etc option is set to outside subcatchments.

Advice

Re-mesh the 2D Zone using the current set of Subcatchment boundaries.

E24386

Subcatchment <subcatchment id> has been added since meshing was performed

Info

2D Zone ID, Subcatchment ID

Cause

The Subcatchment identified intersects a 2D Zone that has been meshed, but was not used to create the current mesh in the 2D Simulation Polygon.

Subcatchments are only used to create a mesh when the 2D Zone option Apply rainfall etc directly to mesh elements is selected and the Apply rainfall etc option is set to outside subcatchments.

This error may be caused by renaming of the Subcatchment.

Advice

Re-mesh the 2D Zone using the current set of Subcatchments.

Alternatively, if the Subcatchment was renamed, reset the Subcatchment ID to the value used when the 2D mesh was created.

E24393

A value must be specified for this field when applying rainfall directly to mesh elements

Info

2D Zone ID

Cause

The Apply rainfall etc directly to mesh elements option of the 2D Zone has been selected, but a Rainfall profile value has not been entered.

Advice

Enter a Rainfall profile value.

E24412

Minimum element area has changed since meshing was performed

Info

2D Zone ID

Cause

The value of the Minimum element area field has been changed since the current 2D mesh was created.

Advice

Re-mesh the 2D Zone using the current minimum element area.

E24653

Must be greater than Depth threshold 1

Info

Roughness definition

Cause

The value specified for Depth threshold 2 is less than the value specified for Depth threshold 1 but it must be greater.

Advice

Check the Depth threshold 1 and Depth threshold 2 values for the relevant Roughness definition object, and ensure that the value specified for Depth threshold 2 is greater than the value specified for Depth threshold 1.

E24770

Lower limit level cannot exceed upper limit level

Info

Mesh Level Zone ID

Cause

The value of the Lower limit level field of the Mesh Level Zone identified is greater than the value of the Upper limit level field.

Advice

Review the Lower limit level and Upper limit level values of the Mesh Level Zone.

E24771

Must be collinear with the boundary of a 2D Zone

Info

2D Boundary Line ID

Cause

The 2D Boundary line identified does not coincide exactly with the boundary of a 2D Zone.

Advice

Edit the 2D boundary line so that it is snapped to the boundary of the 2D Zone boundary.

E24774

Must enter a head unit flow table present in the network

Info

Head unit flow table

Cause

The Boundary line type has been set to Level & Head/discharge but the head unit flow table specified in the Head unit flow table field does not exist for this network.

Advice

Check that the correct head unit flow table has been specified. Note that the required head unit flow table may not have yet been added to this network.

W0007

RTC definition for breach does not exist in the Global regulator

Info

Network object ID

Cause

An RTC definition has been specified in the Section data editor of the network object, but a definition of that ID does not exist in the Global regulator of the RTC.

Advice

Review RTC definition values.

W2025

Node is not connected to a link

Info

Node ID

Cause

Node is disconnected from the network.

Advice

Check node connectivity.

W2030

This might not be a sensible location for a break node. Consider using a manhole or storage node instead

Info

Node ID

Cause

This warning will appear if the following conditions are NOT met for the location of a break node:

  • 1 incoming and 1 outgoing link only

  • Connected link 1 = Conduit

  • Connected link 2 = Flap Valve / Pump / Conduit

or

  • one or more connected links is a river reach or a bridge link

Advice

Check node connectivity.

W2041

Total unit hydrograph area is greater than 1.0

Info

RTK Hydrograph ID

Cause

R1 + R2 + R3 > 0

Advice

Check RTK Hydrograph RTK parameters.

W2042

SWMM5 feature only used if sim parameter "Use SWMM5 RDII" is selected

Info

Max depth - Short/Medium/Long term

Recovery rate - Short/Medium/Long term

Starting depth - Short/Medium/Long term

Cause

A value has been specified for one or more of the fields:

Max depth - Short term, Recovery rate- Short term, Starting depth - Short term, Max depth - Medium term, Recovery rate- Medium term, Starting depth - Medium term, Max depth - Long term, Recovery rate- Long term and Starting depth - Long term

But these Monthly RTk Hydrograph values can only be used in a simulation if the Use SWMM5 RDII option is selected in the simulation parameters.

Advice

Ensure that the Use SWMM5 RDII box is checked in the simulation parameters.

W2049

Storage should be defined in the storage area array or floodable area for this node

Info

Node ID

Cause

Applicable to nodes of Type = Manhole, Flood Type = Inlet.

There are no values defined in the .Storage Level / Plan Area grid or in the Floodable Area field.

Advice

Enter storage data either in the Storage Level / Plan Area grid or in the Floodable Area field.

W2053

Invert above ground level

Info

Conduit ID

Cause

Upstream Invert Level of conduit > Ground Level of upstream node.

Advice

Check level data.

W2054

Soffit above ground level

Info

Conduit ID

Cause

Conduit Upstream Invert Level + Cross Section Height > Ground Level of upstream node.

Advice

Check level data.

W2055

Invert above ground level

Info

Conduit ID

Cause

Downstream Invert Level of conduit > Ground Level of downstream node.

Advice

Check level data.

W2056

Soffit above ground level

Info

Conduit ID

Cause

Conduit Downstream Invert Level + Cross Section Height > Ground Level of downstream node.

Advice

Check level data.

W2075

The roughness value given is outside suggested range (too low) - check whether correct roughness type has been selected

Info

Conduit ID

Cause

Bottom Roughness value is less than the suggested lower limit:

Roughness Type

Lower Limit

Upper Limit

CW

0.1

999.0

Manning

1.0

999.0

N

0.009

0.8

HW 20.0 5000.0

Roughness Type

Lower Limit

Upper Limit

CW

0.1

999.0

Manning

1.0

999.0

N

0.001

0.99

Advice

Check that Roughness Type and Bottom Roughness values are as expected.

W2076

The roughness value given is outside suggested range (too high) - check whether correct roughness type has been selected

Info

Conduit ID

Cause

Top Roughness value is greater than the suggested upper limit:

Roughness Type

Lower Limit

Upper Limit

CW

0.1

999.0

Manning

1.0

999.0

N

0.009

0.8

HW 20.0 5000.0

Roughness Type

Lower Limit

Upper Limit

CW

0.1

999.0

Manning

1.0

999.0

N

0.001

0.99

Advice

Check that Roughness Type and Top Roughness values are as expected.

W2078

Not advisable to include manholes of a 'sealed' flood type as flood points

Info

Flood Point ID

Cause

A sealed manhole has been included as a flood mapping point. Flooding cannot occur at a sealed manhole.

Advice

Check that flood points have been specified as expected.

W2078

Not advisable to include outfalls as flood points unless there is a level attached

Info

Flood Point ID

Cause

An outfall has been included as a flood mapping point.

Advice

Check that flood points have been specified as expected.

W2081

(Shaft plan area) * (2D element area factor) for 2d manhole exceeds area of containing element <mesh element id> in 2D zone <2d zone id>

Info

Node ID

Cause

The effective area of a 2d manhole calculated as

Shaft plan area x 2D element area factor

is greater than the area of the mesh element in which the node is located.

Advice

Check 2d element area factor value is as expected and re-mesh if necessary.

W2085

The cross slope is outside an accepted limit of 0.015 to 0.06

Info

Node ID

Cause

The value specified in the Cross slope field is less than 0.015 or greater than 0.06.

Advice

Review Cross slope value.

W2112

This 2d outfall has ground level not equal to downstream invert level on <link ID>

Info

Node ID

Cause

Applicable to nodes of Type Outfall 2D.

Value in Ground level field is not the same as the Downstream invert level of the connecting outfall link.

Advice

Review ground level value assigned to 2D outfall.

W2126

Minimum speed is equal to maximum speed

Info

Pump ID

Cause

Applicable to pumps of Link type VfdPmp.

Value in Minimum Speed field is the same as the value in the Maximum Speed field (specified on the Regulator Page of the Pump property sheet).

Advice

Review speed values for the pump.

W2171

Overlaps risk impact zone <zone id> which has the same category

Info

Risk Impact Zone ID

Cause

Overlapping Risk Impact Zones have the same Category value.

Each Damage Receptor in the network can only be associated with a single risk impact zone for a given category (to avoid double counting damages within a category). If a Damage Receptor falls within more than one zone of the same category, it will be arbitrarily assigned to one of the zones only.

Advice

Review risk impact zone boundaries and categories.

W2176

No output units type specified

Info

TVD Connector ID

Cause

The Output units type field is blank.

Advice

Valid if the data stream is unitless.

W2177

Rainfall used for modelling must be specified as intensity, not depth. Rainfall depth data will be ignored.

Info

TVD Connector ID

Cause

Input units type and Output units type are set to RD - rainfall depth.

To use the TVD connector as a rain gauge, units must be set to R - rainfall intensity.

Advice

Set units to R- rainfall intensity.

W2179

Input units do not match output units. No unit conversion takes place and the results may not be what was intended.

Info

TVD Connector ID

Cause

Input units type and Output units type are set to different values.

Advice

Set Output units type to same value as Input units type.

W2180

TVD Connector ID should have at least one input or an expression.

Info

TVD Connector ID

Cause

A data stream must be referenced as an input to the TVD connector or an SQL expression must be specified.

Advice

Either specify a data stream in the Input A field or use the SQL Expression dialog which is displayed by clicking on the button located to the right of the Output expression field.

W2218

This 2D Zone contains no 2d/gully 2d manholes and no 2d outfalls

Info

2D Zone ID

Cause

There are no Nodes of Type manhole and Flood Type 2D within the 2D Simulation Polygon.

Advice

Check 2D Zone boundary has been drawn correctly.

Check nodes to be modelled as 2D nodes have been assigned Flood Type = 2D.

W2219

Minimum crest for VCWEIR not set. Minimum width will be used as minimum crest elevation

Info

Weirs

Cause

The type of weir is specified as a Variable Crest Weir (VCWEIR) but as a minimum elevation for a VCWEIR has not been set in the Minimum crest field, the Minimum width will be used instead.

Advice

If you do not want to use the Minimum width setting for a VCWEIR, then ensure that the minimum elevation is set in the Minimum crest field.

W2220

Maximum crest for VCWEIR not set. Maximum width will be used as maximum crest elevation

Info

Weirs

Cause

The type of weir is specified as a Variable Crest Weir (VCWEIR) but as a maximum elevation for a VCWEIR has not been set in the Maximum crest field, the Maximum width will be used instead.

Advice

If you do not want to use the Maximum width setting for a VCWEIR, then ensure that the maximum elevation is set in the Maximum crest field.

W2221

This 2D Zone contains no 2D manholes in its mesh elements

Info

2D Zone ID

Cause

There are Nodes of Type manhole and Flood Type 2D within the 2D Zone, but all of them fall within voids in the 2D mesh.

Advice

Check that the node locations are as expected.

Check that the objects or file used to define voids are as expected.

W2243

Both maximum crest and maximum width specified. Maximum crest will be used for elevation

Info

Weirs

Cause

Both a Maximum crest and a Maximum width have been specified a Variable Crest Weir (VCWEIR).

Advice

InfoWorks ICM uses the specified Maximum crest as the maximum elevation for a Variable Crest Weir. Therefore, a Maximum width setting will not be used and may be removed if required.

W2244

Both minimum crest and minimum width specified. Minimum crest will be used for elevation

Info

Weirs

Cause

Both a Minimum crest and a Minimum width have been specified for a Variable Crest Weir (VCWEIR).

Advice

InfoWorks ICM uses the specified Minimum crest as the minimum elevation for a Variable Crest Weir. The Minimum width setting is only used if a Minimum crest is not specified.

W2245

Less than minimum crest/width value

Info

Weirs

Cause

The value specified for either the Minimum crest or Minimum width is lower than the permitted minimum value.

Advice

Change the value for the Minimum crest or Minimum width field to one that is within the permitted range.

W2246

Exceeds maximum crest/width value

Info

Weirs

Cause

The value specified for either the Minimum crest or Minimum width is higher than the permitted maximum value.

Advice

Change the value for the Minimum crest or Minimum width field to one that is within the permitted range.

W2262

Maximum triangle area recommended to be greater than minimum element area

Info

2D Zone ID

Cause

The value specified in the Maximum Triangle Area field of the 2D Zone is greater than or equal to the Minimum Element Area value specified for the polygon.

Advice

It is recommended that the Maximum Triangle Area of the 2D Zone be set to greater than the Minimum Element Area.

W2264

No value specified for this field so rainfall will be applied everywhere

Info

2D Zone ID

Cause

The Apply rainfall etc directly to mesh elements option for the 2D Zone is selected, but an option has not been selected for the Apply rainfall etc field.

Rainfall will be applied everywhere by default.

Advice

Select an option from the Apply rainfall etc dropdown list of options.

W2277

More than 0.2

Info

Runoff Surface ID

Cause

Applicable to Runoff Surfaces with Initial Loss Type = SCS.

Initial Loss > 0.2

Advice

Check Initial Loss value of reported Runoff Surface.

W2278

More than 0.02

Info

Runoff Surface ID

Cause

Applicable to Runoff Surfaces with Initial Loss Type = Abs or Slope.

Initial Loss > 0.02

Advice

Check Initial Loss value of reported Runoff Surface.

W2279

Less than 0.002

Info

Runoff Surface ID

Cause

0.0 < Ground Slope < 0.002

Advice

Check Ground Slope value of reported Runoff Surface.

W2283

Maximum triangle area recommended to be greater than minimum element area

Info

Mesh Zone ID

Cause

The Override 2D Zone minimum element area setting option for the mesh zone is checked and the value specified in the Maximum Triangle Area field is greater than or equal to the Minimum Element Area value specified for the zone.

Advice

It is recommended that the Maximum Triangle Area of the Mesh zone be set to greater than the Minimum Element Area.

W2285

Element <element id> has area (<element area>) less than 50% of minimum element area (<min element area>)

Info

Mesh Element ID

Cause

One or more elements in the mesh has area less than 50% of the specified Minimum element area for the zone.

In areas where a mesh zone overlaps the 2D zone; the Minimum element area of the mesh zone will be used if the mesh zone's Override 2D zone minimum element area setting is checked.

The warning will be displayed for one element per mesh only; although the warning may apply to more than one element in the mesh.

Advice

Smaller elements may impact on 2d simulation performance.

Simplify the mesh to improve performance.

W2286

Maximum triangle area recommended to be greater than minimum element area on 2d Zone <2d Zone id>

Info

Mesh Zone ID

Cause

This warning message will be displayed for a Mesh zone with:

  • Override 2D Zone minimum element area setting option unchecked
  • Maximum Triangle Area field greater than or equal to the Minimum Element Area value specified for the 2D Zone in which the mesh zone is located.

Advice

It is recommended that the Maximum Triangle Area of the Mesh zone be set to greater than the Minimum Element Area of the 2D Zone in which the mesh zone is located.

W2288

Runoff volume type 'DefConLoss' may be inappropriate for impervious surfaces

Info

Runoff surface ID

Cause

The Runoff volume type has been set to DefConLoss but this model may not be the most appropriate for an impervious type of surface.

Advice

This may be intentional. But if not, check that the correct parameters have been specified for the Surface type and Runoff volume type for this Runoff surface and change as required.

W2300

Roughness value given is outside suggested range (too low)

Info

Network object ID

Cause

The specified roughness value is greater than the suggested lower limit:

Roughness Type

Lower Limit

Upper Limit

CW (Colebrook-White)

0.1

999.0

Manning (Manning's 1/n)

1.0

999.0

N (Manning's N)

0.009

0.8

HW (Hazen Williams) 20.0 5000.0

Advice

Check the specified roughness value and ensure that it is within the permitted range.

W2301

Roughness value given is outside suggested range (too high)

Info

Network object ID

Cause

The specified roughness value is greater than the suggested upper limit:

Roughness Type

Lower Limit

Upper Limit

CW (Colebrook-White)

0.1

999.0

Manning (Manning's 1/n)

1.0

999.0

N (Manning's N)

0.009

0.8

HW (Hazen Williams) 20.0 5000.0

Advice

Check the specified roughness value and ensure that it is within the permitted range.

W2306

No rainfall profile specified for subcatchment which has runoff surface areas defined

Info

Subcatchment ID

Cause

A Rainfall profile, which provides the source of the rainfall data to be applied to the subcatchment during a simulation, is normally required for this subcatchment but none has been specified.

Advice

This may be intentional, for example, if you want to simulate infiltration only, then you may want to omit the rainfall profile from the subcatchment properties.

If not intentional, check the Subcatchment properties and ensure that a Rainfall profile is specified.

W2309

This subcatchment drains to a node (or link) of a different system type

Info

Subcatchment ID

Cause

The System type of the subcatchment is different to the system type of the subcatchment's receiving node.

If the subcatchment drains to a link, the warning is displayed if the link to which the subcatchment drains is of a different System type to the subcatchment.

Advice

Check System Type of reported Subcatchment is as expected.

W2331

You are mixing Wallingford and Fixed runoff volume surfaces. The fixed surfaces will use the default PR distribution factor for the surface type

Info

Land Use ID

Cause

Runoff Surfaces associated with the reported Land Use include those of Runoff Volume Type = Wallingford and Runoff Volume Type = Fixed

Advice

This may be intentional.

If not, check that the correct Runoff Surfaces have been associated with the reported Land Use object.

Check the Runoff Volume Types assigned to associated Runoff Surfaces.

W2351

Results object not in 2D zone

Info

Network results polygon (2D) ID

Cause

The network results polygon (2D) identified is not fully within a 2D zone. There will be no results generated for the polygon.

Advice

Review location of the results polygon.

W2361

User-defined lateral weights do not sum to unity

Info

Subcatchment

Cause

The specified weights of the lateral links do not add up to 1.

Advice

Check that proportion of the Weights specified for each Lateral links total 1.

W2374

Limit is 0.25 when routing model is 'RAFTS'

Info

Runoff surface ID

Cause

The value specified for the Equivalent Manning's n field is greater than the 0.25 value recommended by RAFTS, but below the maximum value of 2.0 permitted in ICM, when the runoff routing model is set to RAFTS.

Advice

Review the value of Equivalent Manning's n and the routing model selection in the runoff surface properties.

W2376

Results object not in 2D zone

Info

Network results line (2D) ID

Cause

The network results line (2D) identified is not fully within a 2D zone. There will be no results generated for the line.

Advice

Review location of results line.

W2383

Monthly RTK hyrographs are only used if sim parameter "Use SWMM5 RDII" is selected

Info

RTK hydrograph ID

Cause

The Use SWMM5 RDII option in the simulation parameters is unchecked but a monthly RTK hydrograph has been specified for this network.

Advice

Monthly RTK Hydrographs can only be included if the Use SWMM5 RDII option is used for the simulation. Ensure that this box is checked in the simulation parameters.

Alternatively, check that the correct RTK hydrograph ID has been specified in the subcatchment parameters.

W2398

No limit is applied when capacity limit has a zero value

Info

Subcatchment ID

Cause

The Limit drain to capacity box has been checked for the subcatchment, but either no Capacity limit has been specified or it has been set to 0. This means that no limit will be applied to the runoff for this subcatchment.

Advice

Specify a non-zero value in the Capacity limit field if you want to apply a runoff limit for this subcatchment.

W2399

Limit is 0.25 when routing model is 'RAFTS'

Info

Subcatchment ID

Cause

The value specified for the Equivalent Manning's n field is greater than the 0.25 value recommended by RAFTS, but below the maximum value of 2.0 permitted in ICM, when the runoff routing model is set to RAFTS.

Advice

Review the value of Equivalent Manning's n in the subcatchment properties and the routing model selection in the runoff surface properties.

W2401

Results object not in 2D zone

Info

Network results point (2D) ID

Cause

The network results point (2D) identified is not within a 2D zone. There will be no results generated for the point.

Advice

Review location of results point.

W2433

Field not entered. 'Fully controlled' value will be assumed.

Info

Bridge linear structure (2D) ID

Cause

The Overtopping flow type field is set to null.

A value of 'Fully controlled' will be used.

Advice

Select an Overtopping flow type option.

W2482

Null mesh generation is interpreted as the 'Classic' mesh generation option

Info

2D Zone ID

Cause

A method of Mesh generation has not been specified for this 2D zone, therefore the Classic method will be used when the mesh is generated.

Advice

If you do not want the mesh for this 2D zone to be generated using the Classic method, then ensure that the Mesh generation property is set to the appropriate method.

W2516

Node exists in network with the same name

Info

Point Source ID

Cause

The 2D Point Source identified has the same ID as a node in the network. Inflow Event profiles using the ID as a node reference will be associated with the node and not the 2D Point Source.

Advice

Rename the 2D Point Source so that it uses a unique ID.

W2530

Manning values differ by more than 20 percent within a panel

Info

Channel ID

Cause

This message applies to the Channel Shape associated with the identified Channel.

The difference between Manning's n values within the same panel in the Channel Profile editor of the Channel Shape, is greater than 20%.

Advice

Review channel profile data.

W2553

Outgoing conduit US invert level mismatch

Info

Culvert Inlet ID

Cause

The US invert level of the conduit connected downstream of the culvert inlet is not the same as the Invert level of the culvert inlet.

Mismatch in invert level may result in simulation problems or failures.

Advice

Review invert levels at culvert inlet and connected downstream conduit.

W2580

Incoming conduit DS invert level mismatch

Info

Culvert Outlet ID

Cause

The DS invert level of the conduit connected upstream of the culvert outlet is not the same as the Invert level of the culvert outlet.

Mismatch in invert level may result in simulation problems or failures.

Advice

Review invert levels at culvert outlet and connected upstream conduit.

W2615

Not inside any 2D zone: Z1, Z2

Info

2D line source (Line X,Y)

Cause

The 2D line source is not located within any 2D zone.

Roughness Type

Lower Limit

Upper Limit

CW

0.1

999.0

Manning

1.0

999.0

N

0.001

0.99

Advice

Check the location of the 2D line source to ensure that it is located within a 2D zone boundary.

W2617

Overlaps boundary of 2D zone Z1

Info

2D line source (Line X,Y)

Cause

The 2D line source overlaps the boundary of the Z1 zone of the 2D boundary.

Roughness Type

Lower Limit

Upper Limit

CW

0.1

999.0

Manning

1.0

999.0

N

0.001

0.99

Advice

Check the location of the 2D line source to ensure that it is located within a 2D zone boundary.

W2650

The roughness value given is outside suggested range (too low) - check whether correct roughness type has been selected

Info

Channel Shape ID

Cause

Profile Roughness value is less than suggested lower limit:

Roughness Type

Lower Limit

Upper Limit

CW

0.1

999.0

Manning

1.0

999.0

N

0.009

0.2

Roughness Type

Lower Limit

Upper Limit

CW

0.1

999.0

Manning

1.0

999.0

N

0.001

0.99

Advice

This may be intentional if representing 'dead' flood plain storage.

Check that Roughness Type and Roughness values are as expected.

W2651

The roughness value given is outside suggested range (too high) - check whether correct roughness type has been selected

Info

Channel Shape ID

Cause

Profile Roughness value is greater than suggested upper limit:

Roughness Type

Lower Limit

Upper Limit

CW

0.1

999.0

Manning

1.0

999.0

N

0.009

0.2

Roughness Type

Lower Limit

Upper Limit

CW

0.1

999.0

Manning

1.0

999.0

N

0.001

0.99

Advice

Check that Roughness Type and Roughness values are as expected.

W2670

Building <Building_ID> is outside 2D Zone

Info

Building

Cause

Part of the boundary of the building lies outside of the 2D Zone. It will not be included in the 2D results unless all the building boundaries are included within the 2D Zone.

Advice

Edit the geometry of either the building polygon or the 2D Zone polygon to ensure that all the building's boundaries are within the 2D Zone.

W2698

No Turbulence model (2D) assigned

Info

Turbulence Zone (2D)

Cause

A Turbulence Model (2D) has not been selected for the Turbulence Zone (2D).

Advice

Select a Turbulence Model (2D) from the list of available models or create a new one.

W2703

No infiltration surface (2D) assigned

Info

Infiltration Zone (2D)

Cause

An Infiltration Surface has not been selected for the Infiltration Zone (2D).

Advice

Select an Infiltration Surface from the list of available surfaces or create a new one.

W2729

User-defined lateral weights do not sum to unity

Info

Lateral weights

Cause

The Lateral weights field for the Permeable Zone (2D) is set to User but the values entered on the lateral links grid to not add up to 1.

Advice

Click on the button, located in Lateral links field, to display the lateral links grid editor and ensure that the weights specified for all the links add up to 1.

W2731

No 2D mesh elements associated with this permeable zone (2D)

Info

Permeable Zone (2D)

Cause

No 2D mesh elements are associated with this Permeable Zone (2D).

Advice

Check the geometry of the 2D permeable zone and mesh polygons and ensure that the mesh triangles have their centroids contained within the permeable zone.

W2889

Overlaps 2d zone boundary or void edges. 2D engine will treat overlapping portions as walls.

Info

Base Linear Structure (2D) ID

Cause

The Base linear structure overlaps a 2D mesh boundary.

The Base linear structure will be treated as an infinitely high wall during the simulation.

Advice

Review location of Base linear structure.

W2908

Field not entered: 'Fully controlled' value will be assumed

Info

Sluice linear structure (2D) ID

Cause

There is no value set in the Flow type or the Overtopping flow type field.

A value of Fully controlled will be assumed.

Advice

Review Flow type or Overtopping flow type values.

W7785

Headloss type is inappropriate for this object

Info

Object ID

Cause

US headloss type or DS headloss type field has been set to NORMAL or HIGH and one or more of the following conditions is met:

  • object is of type Bridge, Bridge Opening or River Reach
  • object is a conduit of an open channel type
  • object is a conduit attached to a break node or pond at link end with NORMAL/HIGH headloss type
  • object is a barrel conduit (connected immediately downstream of a culvert inlet or immediately upstream of a culvert outlet) attached to culvert at link end with NORMAL/HIGH headloss

NORMAL and HIGH headloss curves represent extra energy losses due to turbulence at a surcharged manhole or junction and are not appropriate in the above situations.

In the case of a barrel conduit, the culvert inlet/outlet should be handling any transition losses, so the only appropriate headloss types at the barrel end should be NONE or FIXED (to represent any bend losses in the barrel).

Advice

Set headloss type fields to FIXED or NONE.

W7795

Bank should have at least 2 section markers

Info

River Reach ID, Left/Right river bank

Cause

There are less than two Section marker IDs specified in the Left river bank or Right river bank field of the river reach.

Advice

Check that Section marker IDs have been specified as expected.

W7799

Bank connection for 2d zone overlaps mesh more than once. Only one part of the bank will be used

Info

Bank line of a River Reach

Cause

The bank line of a River Reach intersects with more than one polygon, so only the first connection to the 2D zone is considered.

Advice

Split the River Reach at the intersection of polygons.

W7810

Manning values differ by more than 20 percent within a panel on section <section ID> at point <row ID>

Info

River Reach ID, section ID

Cause

The difference between Manning's n values within the same panel in the identified section at the identified row, is greater than 20%.

Advice

Review section data.

W7812

Manning values on section <section ID> are outside of recommended range 0.009 - 0.2

Info

River Reach ID, section ID

Cause

Roughness Manning's n specified in River Sections Editor for identified section is less than 0.009 or more than 0.2.

Advice

Review section data.

W7814

Chainage of section <section ID> differs from the preceding section by less than the minimum space step

Info

River Reach ID, section ID

Cause

The distance between the identified section and its upstream section is less than the Minimum space step specified in the Simulation Parameters.

The distance validated is either the Distance to next section (set in the River Sections Editor) when using specified section spacing, or the length along the river reach link between sections otherwise.

Advice

Review section data.

W7816

Roughness values are outside of recommended range 0.009 - 0.2

Info

Bridge ID, Bridge section

Cause

Roughness Manning's n specified in the Section Editor for the identified section is less than 0.009 or more than 0.2.

Advice

Review section data.

W7818

Roughness values vary by more than 20 percent within a panel at point <row ID>

Info

Bridge ID, Bridge section

Cause

The difference between Manning's n values specified in the Section Editor for the identified section at the identified row, is greater than 20%.

Advice

Review section data.

W7819

Cross section/Bank line <line id> has had its geometry changed since sections were last built

Info

Cross section / Bank line ID

Cause

Vertex x, y coordinates of the cross section line or bank line used to build a river reach have been changed since the reach was built.

Advice

Rebuild river reach sections/banks from survey lines.

W7820

Cross section/Bank line <line id> has been deleted since sections/banks were last built

Info

Cross section / Bank line ID

Cause

Cross section line or bank line used to build a river reach has been deleted or renamed since the reach was built.

Advice

Rebuild river reach sections/banks from survey lines.

W7821

Sections/Banks have changed since the boundary was last built

Info

River reach ID

Cause

Vertex x, y coordinates of river reach sections or banks used to build the river reach boundary have been changed since the boundary was built.

Advice

Rebuild river reach boundary from banks and section ends.

W7829

Bank point at <X,Y> has level <Z> below the lowest point on section <section id>

Info

River reach

Cause

The bank line level is lower than the relevant river reach section invert (lowest point).

Advice

The bank line level (Z) should not be lower than the lowest point on the river reach section. Check the bank line level at the indicated point (X,Y) and change if necessary.

W9001

Value above recommended value of <recommended upper limit>

Info

Object ID, Object Field, Recommended upper value

Cause

The recommended maximum value in the field indicated by the error message has been exceeded.

Advice

Check that values are as expected.

W9001

Value below recommended value of <recommended lower limit>

Info

Object ID, Object Field, Recommended lower value

Cause

The value in the field indicated by the error message is less than the recommended minimum value.

Advice

Check that values are as expected.

W22150

Max depth will be adjusted to match the top of the highest connecting conduit

Info

Node ID

Cause

The maximum depth specified for a node is less than the highest elevation of a connecting conduit but it must be at least the same.

Advice

InfoWorks ICM has automatically changed the node's Max depth value so that it is equal to the connected conduit with the highest Downstream elevation or Upstream elevation.

W22151

Ground level is below invert elevation

Info

Node ID

Cause

The ground level for a node is less than its invert elevation but it must be at least the same or greater than it.

Advice

Check the values specified for the node's Ground level and Invert elevation and ensure that the Ground level value is the same or greater than the value for its Invert elevation.

W22218

Choosing a non-default value for the shape factor will result in a unit hydrograph that does not conserve volume

Info

Subcatchment ID

Cause

You have chosen to use a Runoff model type of SCS_Curvilinear for the subcatchment, but the value you have specified in the Shape factor field is not the default value of 484, so the resulting unit hydrograph will not conserve volume.

Advice

If you want the resulting unit hydrograph to conserve volume, then you must either specify a value of 484 in the Shape factor field, or choose a different Runoff model type.

W22454

Fractions units are only for pumps, orifices, weirs and outlets

Info

TVD Connector ID

Cause

The selected type of Output units is FRAC (fraction) but this can only be used with a pump, orifice, weir or outlet type of connected object.

Advice

Either change the Connected object type to Pump, Orifice, Weir or Outlet or, if the correct type of connected object has been specified, choose a different type of Output units.

W22951

Minimum elevation drop used

Info

Link ID

Cause

The difference between the specified Upstream elevation and Downstream elevation of the conduit is less than the minimum requirement of 0.00035 m (0.001 ft).

Advice

InfoWorks ICM used the minimum required elevation difference of 0.00035 m (0.001 ft) in order to calculate the conduit's slope.

W22952

Depth threshold is greater than the current conduit height

Info

Link ID

Cause

The specified Depth threshold of a conduit is greater than its specified Conduit height.

Advice

Either change the Depth threshold value so that it is smaller than the specified Conduit height or increase the Conduit height value.

W22954

Upstream/Downstream elevation is below the invert elevation of the upstream/downstream node. Value will be ignored

Info

Link ID

Cause

The specified Upstream elevation / Downstream elevation of a conduit is below the specified Invert elevation of the upstream /downstream node it is connected to but this not allowed.

Advice

InfoWorks ICM will ignore the conduit's specified Upstream elevation or Downstream elevation.

W22955

Elevation drop exceeds the conduit's length

Info

Link ID

Cause

The difference between the specified upstream and downstream elevation (or vice versa) of a conduit is greater than the length of the same conduit.

Advice

Check the conduit's specified Upstream elevation and Downstream elevation and ensure that the difference between them is not greater than the conduit's specified Length.

W23003

Crest elevation is below downstream invert for regulator link

Info

Link ID

Cause

The height of the opening for an orifice, weir, or an outlet is below the invert elevation of its downstream (end) node.

Advice

Check the Invert level value specified for the orifice, the Crest height for a weir, or the Outlet height for an outlet , and ensure that it is 'lower' than the relevant node's Invert level.

W24387

Maximum triangle area recommended to be greater than minimum element area

Info

2D Zone ID

Cause

The value specified in the Maximum triangle area field of the 2D Zone is greater than or equal to the Minimum element area value specified for the polygon.

Advice

It is recommended that the Maximum triangle area of the 2D Zone be set to greater than the Minimum element area.

W24394

No value specified for this field so rainfall will be applied everywhere

Info

2D Zone ID

Cause

The Apply rainfall etc directly to mesh elements option for the 2D Zone is selected, but an option has not been selected for the Apply rainfall etc field.

Rainfall will be applied everywhere by default.

Advice

Select an option from the Apply rainfall etc dropdown list.

I2040

This manhole (and possibly others) has shaft area / chamber area below minimum in Simulation Parameters

Info

Node ID

Cause

The shaft or chamber area of the node is less than the Minimum Plan Area at Nodes defined in the Simulation Parameters Dialog.

Advice

Check that the shaft and chamber area of the node are as expected.