Orifice Data Fields (InfoWorks)

An orifice plate controls the discharge from a storage tank or pond. It consists of a plate with a hole, usually circular, for the flow to pass through.

Orifice data can be edited on either the Orifice Grid Window of the Links Grid or the Orifice Property Sheet.

To view and edit all orifice data, use the Property Sheet.

This table describes all the orifice specific data which can be used to define an orifice. For details of results fields, see the Link Results Data Fields topic.

Fields that are common to the majority of objects can be found in the Common Fields topic.

Orifice Data

Database Table Name: hw_orifice

Field Name

Description

Database Field

Data Type

Size

Units

Precision

Default

Error Lower Limit

Error Upper Limit

Warning Lower Limit

Warning Upper Limit

US node ID

The ID of the upstream node for this orifice. An existing node ID can be selected from the dropdown. This makes up the first part of the link reference.

us_node_id

Text

64

0

DS node ID

The ID of the downstream node for this orifice. An existing node ID can be selected from the dropdown.

ds_node_id

Text

64

0

Link suffix

A single character between A and Z or 0 and 9 which completes the link reference. This allows a node to have up to 36 downstream links. The suffix is automatically allocated by the software.

link_suffix

Text

1

0

1

Link type

The sub-type of orifice can be set to:
  • Orific
  • Vldorf

link_type

Text

6

0

ORIFIC

Asset ID

For reference only. Designed as a reference to an asset database, but could be used for anything.

asset_id

Text

64

0

Sewer reference

An optional reference to identify the sewer of which this conduit is a part.

sewer_reference

Text

80

0

System type

The system type can be selected from the dropdown. See System Type for more information.

system_type

Text

10

0

Other

Branch ID

Identifies which long section the link is associated with.

Can be set manually or automatically (see Defining Branches topic for more information).

branch_id

Long Integer

0

0

US settlement efficiency (%)

Relevant to Water Quality Simulations only.

The settlement efficiency fields allow you to set the effectiveness of an overflow for trapping out sediment. The overflow is a link (normally a pipe) attached to a node acting as a storage tank (storage node or manhole).

Normally the upstream end of the link will be attached to the node and act as the overflow.

The upstream settlement efficiency determines the efficiency for the overflow.

In some circumstances the link may be reversed (storage tank at the downstream end) and the downstream settlement efficiency will be used.

In many cases an overflow will attach to an outfall from the system.

It would be very unusual to have both upstream settlement efficiency and downstream settlement efficiency set to non-zero values.

The valid range is 0-100%. 0% means the overflow acts as a normal continuation link. 100% means that the overflow traps out as much sediment as possible.

us_settlement_eff

Long Integer

0

0

0

100

DS settlement efficiency (%)

Relevant to Water Quality Simulations only.

See US Settlement Efficiency.

ds_settlement_eff

Long Integer

0

0

0

100

Invert level

The level at which the orifice comes into operation. There is no default value for this field, the valid range is -99.9 to 999.9

Orifice parameters

invert

Double

Z

3

-9999

9999

6000

Discharge coefficient

This is the coefficient for the orifice flow equations. The discharge theory for an orifice predicts a typical velocity and concentration coefficient to be 1.0, which is the default value. The valid range is 0.01 to 999.9. Values typically range between 0.2 and 3.0

discharge_coeff

Double

2

1

0.01

Secondary discharge coefficient

This applies when the depth of water is less than the diameter of the orifice, and weir equations apply. The default is the primary discharge coefficient for an orifice with its Opening type not set or set to Side.

For an orifice with its Opening type set to Bottom, default for the Secondary discharge coefficient is 0.587.

secondary_discharge_coeff

Double

2

0.587 (only if Opening type set to Bottom)

0.01

Diameter

Diameter of circular orifice. You should use the diameter of equivalent area for non-circular orifices. There is no default for this field; the valid range is 0 to 999.9

diameter

Double

L

3

0.0

0.01

Limiting discharge

The maximum discharge from upstream to downstream allowed through the orifice. The valid range is 0 to 999.9. If the value is greater than zero, this will be the maximum positive flow allowed through the orifice.

For variable discharge orifice controls (Vldorf) this value is used for the initial limiting discharge.

The default value is zero. A value of zero, or a blank field, means no restriction on maximum discharge for an Orific type of orifice. For a Vldorf type of orifice, a limit of zero is imposed when the Limiting discharge is set to 0.

limiting_discharge

Double

Q

3

0

Opening type

The type of opening can be set to:
  • Side
  • Bottom

opening_type

Text

10

Side

Minimum flow

Displayed when Link type set to Vldorf.

The minimum limiting discharge for the orifice.

minimum_flow

Double

Q

3

0

0

Maximum flow

Displayed when Link type set to Vldorf.

The maximum limiting discharge for the orifice.

maximum_flow

Double

Q

3

999

0

Positive change in flow

Displayed when Link type set to Vldorf.

The rate at which the limiting discharge for the orifice increases. The value must be greater than zero.

This applies to RTC controlled orifice discharge rates. Flow data from TVD connectors will be applied directly to the orifice.

positive_change_in_flow

Double

DQ

5

0.000001

Negative change in flow

Displayed when Link type set to Vldorf.

The rate at which the limiting discharge for the orifice decreases. The value must be greater than zero.

This applies to RTC controlled orifice discharge rates. Flow data from TVD connectors will be applied directly to the orifice.

negative_change_in_flow

Double

DQ

5

0.000001

Threshold

Displayed when Link type set to Vldorf.

The minimum change in limiting discharge that the software will implement. Any smaller change will be ignored. This prevents oscillation.

threshold

Double

Q

3

0

0

Points

The geometry of the link. The underlying data consists of a series of (x,y) pairs defining the vertices of the link. Each link is made up of a series of straight lines between the defined (x,y) points.

This data is not displayed on the grid or property sheet.

Link Vertice Export
Link vertices are included when you export link data to CSV files. There are two options available for exporting link vertices. These are selected on the Select CSV Export Options Dialog using the Coordinate Arrays Format dropdown list. The options are:
  • Packed - The data is exported as a series of x,y pairs.
  • Separately - the data is appended to the end of the row containing the link data. Each x and y value is in a separate (comma separated) field.

point_array

Array

XY

0

InfoAsset unique ID

Unique ID associated with the corresponding object in an InfoAsset Manager database. When importing from InfoAsset Manager, the InfoAsset ID can be copied from the InfoAsset database in order to maintain links between the two networks.

asset_uid

GUID

0

0

0

0

0

InfoAsset ID

Used to store the ID of the corresponding InfoAsset object when Importing from a Collection Network.

infonet_id Text 40 0