The integration with DemandWatch is performed in the Fields tab of the baseline, by setting values in the Demand Scaling and Demand Scaling (Category by Area) tabs.
Instructions are given below.
- On the Fields page of the Baseline property sheet, select the Demand Scaling tab.
- Enable the Updatable from live data option for the desired areas.
- For each area:
- Specify a live data feed.
- Ensure Mode of Operation is set to Forecast.
- Ensure Forecast unit is set to Day(s) and Forecast Value to 0.
- Enable the DemandWatch option (tick the checkbox).
- Save these changes by clicking the Save button in the bottom right corner of the Baseline properties sheet.
- Select the Demand Scaling (Category in Area) tab.
- Select the desired area in the Demand Area column.
- Edit the DemandWatch Mode for the desired categories.
- Save the changes by clicking the Save button in the bottom right corner of the Baseline properties sheet.