Error and warning messages relating to the Baseline property sheet are displayed in the Output Window when the Baseline is validated.
These are identified by the following symbols:
Warning - action may be required
Error - action necessary
Error Message Number |
Error Message |
Cause |
Priority |
---|---|---|---|
E9000 |
A value must be specified for this field |
A required field is null. A value must be entered in the field. |
|
E9001 |
Value too small. Minimum value is <minimum value>, or Value too large. Maximum value is <maximum value> |
A value is outside of minimum or maximum set in metadata. Enter a valid value in this field. |
|
E9510 |
Default Sim is not set |
A simulation has not been selected in the Default Simulation selection box on the Schedule page. |
|
E9511 |
Cannot find Default Simulation |
The simulation selected in the Default Simulation selection box on the Schedule page cannot be found. |
![]() |
E9512 |
Simulation did not complete successfully |
The simulation selected in the Default Simulation selection box on the Schedule page did not run successfully. |
![]() |
E9513 |
Only normal runs are allowed for the Default Sim |
The simulation selected in the Default Simulation selection box on the Schedule page was not of Run Type Normal. |
![]() |
E9514 |
Run every cannot be zero |
The Run every parameter in the Run Schedule grid of the Schedule page is set to zero. |
![]() |
E9515 |
Duration cannot be zero |
The Duration parameter in the Run Schedule grid of the Schedule page is set to zero. |
![]() |
E9516 |
Tidy up after cannot be zero |
The Tidy up after parameter in the Run Schedule grid of the Schedule page is set to zero. |
![]() |
E9517 |
Archive after cannot be zero |
The Archive after parameter in the Run Schedule grid of the Schedule page is set to zero. |
![]() |
E9518 |
Delete after cannot be zero |
The Delete after parameter in the Run Schedule grid of the Schedule page is set to zero. |
![]() |
E9519 |
Demand categories are different from Default Sim |
A Demand Diagram selected in the Switch Options page contains different demand categories to the Demand Diagram used by the default simulation specified in the Schedule Page. |
![]() |
E9520 |
Demand scaling areas are different from Default Sim |
A Demand Scaling selected in the Switch Options page contains different demand scaling areas to the Demand Scaling used by the default simulation specified in the Schedule Page. |
![]() |
E9521 |
Energy factor regimes are different from Default Sim |
An Energy CO2 Factor selected in the Switch Options page contains different CO2 factor regimes to the Energy CO2 Factor used by the default simulation specified in the Schedule Page. |
![]() |
E9522 |
Electricity tariff labels are different from Default Sim |
An Electricity Tariff selected in the Switch Options page contains different tariff labels to the Electricity Tariff used by the default simulation specified in the Schedule Page. |
![]() |
E9525 |
Validation failed for control n (where n is the name of the control) |
The object mentioned in the error message has not passed validation. It is recommended to validate the object on its own to investigate the exact reason for the validation failure. |
![]() |
E9526 |
Validation failed for demand diagram n (where n is the name of the demand diagram) |
The object mentioned in the error message has not passed validation. It is recommended to validate the object on its own to investigate the exact reason for the validation failure. |
![]() |
E9527 |
Validation failed for demand scaling n (where n is the name of the demand scaling) |
The object mentioned in the error message has not passed validation. It is recommended to validate the object on its own to investigate the exact reason for the validation failure. |
![]() |
E9528 |
Validation failed for electricity tariff n (where n is the name of the electricity tariff) |
The object mentioned in the error message has not passed validation. It is recommended to validate the object on its own to investigate the exact reason for the validation failure. |
![]() |
E9529 |
Validation failed for UPC scenario n (where n is the name of the scenario) |
The object mentioned in the error message has not passed validation. It is recommended to validate the object on its own to investigate the exact reason for the validation failure. |
![]() |
E9530 |
No live data feed specified |
In the Fields tab, the Updatable from live data option is checked for a field, but a Live data feed has not been specified. |
![]() |
E9531 |
Default is less than minimum |
In the Fields tab, the value specified in the Default field is less than the value specified in the Min field. |
![]() |
E9532 |
Default is greater than maximum |
In the Fields tab, the value specified in the Default field is greater than the value specified in the Max field. |
![]() |
E9533 |
Minimum is greater than maximum |
In the Fields tab, the value specified in the Min field is greater than the value specified in the Max field. |
![]() |
E9534 |
Unit in live data feed is not valid for this field |
The unit of measurement in the live data feed is not valid for this field. The unit of measurement for a field on the Fields tab should be the same as the unit specified in the External Units field in the Live Data Feed tab in the Live Data Configuration object . |
![]() |
E9536 |
Live data feed not found in live data configuration |
A live data feed specified in the Live data field 1 field or the Live data field 2 field of the Fields tab does not exist in the Live Data Configuration object associated to the baseline (Live Data Options tab). |
![]() |
E9544 | Both UPC Object and UPC Scripts | A UPC Script has been defined in the Fields tab for a valve or pump station object and the Default Simulation selected in the Schedule tab uses a UPC Scenario and/or a UPC Scenario is specified in the Switch tab. Simulations cannot be run using both UPC Scenario and UPC Scripts. |
![]() |
E9545 | Override is less than minimum |
Mode of operation is set to Use override and the Override value is less than the Min value specified for the field. |
![]() |
E9546 | Override is greater than maximum |
Mode of operation is set to Use override and the Override value is greater than the Max value specified for the field. |
![]() |
W9510 |
No switch objects specified |
A Switch Controller and/or switch script have been specified on the Switch Options page, but there are no Switch Objects selected. |
![]() |
W9511 |
No weather feed specified |
A weather feed has not been specified on the Weather page of the Switch Controller selected in the Switch Options page. |
![]() |
W9512 |
No weather forecast location specified |
A location has not been specified on the Weather page of the Switch Controller selected in the Switch Options page. |
![]() |
W9513 |
No switch script specified |
Switch objects and/or a Switch Controller has been selected in the Switch Options page, but there is no Switch Script. |
![]() |
W9514 |
No warning template specified |
A Warning Template has not been selected in the Display page. |
![]() |
W9515 |
No warning theme specified |
A Warning Theme has not been selected in the Display page. |
![]() |
W9516 |
No switch controller specified |
Switch objects and/or a Switch Script has been selected in the Switch Options page, but no Switch Controller has been selected. |
![]() |
W9517 |
Sim results location should be on the server |
There are no results available on the server for the Default Simulation selected in the Schedule page. |
![]() |
W9518 |
No sim results present |
There are no results available for the Default Simulation selected in the Schedule page. |
![]() |
W9519 |
No electricity tariff theme specified |
There is no electricity tariff theme specified in the Pumps page of the baseline property sheet. |
![]() |
W9520 |
Theme is not an electricity tariff results theme |
The theme specified in the Pumps page of the baseline property sheet is not of the correct type. |
![]() |
W9521 |
Pump station selection list contains other objects |
The selection list specified in the Pumps page of the baseline property sheets contains objects other than pump stations and is therefore invalid. |
![]() |
W9524 |
No warning theme specified |
Zones have been defined in the Zones page of the baseline property sheet but no warning theme has been specified. |
![]() |