Quickstart Pack tutorial: Enter the study parameters
In this task, you set up and run the pack analysis.
Click
(Home tab > Molding Process Setup > Analysis Sequence).
Click Fill + Pack.
Click OK.
Click
(Home tab > Molding Process Setup > Select Material).
Verify that the Manufacturer is Training Materials and that the Trade Name is Training ABS 01 Unfilled VI(240)0053.
Click OK.
Click
(Home tab > Molding Process Setup panel > Process Settings).
Ensure that the Mold surface temperature is 80° C.
This is the recommended Mold surface temperature for this material.
Ensure that the Melt temperature is 260° C.
This is the recommended Melt temperature for this material.
Set the Filling control to Flow rate of 48 cm^3/s.
In the previous task, a Fill analysis was run on a single cavity. In the Model details section of the Analysis Log, the volume of a single cavity is 13.1058 cm^3. The Process settings section of the log shows a Fill time of 1.1 seconds. This is the time we want all four cavities to fill. To achieve this, we need to specify a flow rate given by:
(No. Cavities x Cavity volume) / Fill time
or (4 x 13.1058) / 1.1 = 47.657 cm^3 /s.
This value was rounded to 48 cm^3/s.
Click Edit Profile for the Pack/holding control.
Set the profile 0 - 80%, 10 - 80%.
Click OK twice.
Click
(Home > Analysis > Analyze).
Ensure a computer is selected. Typically the localhost is selected.
Click Launch. The analysis takes around 15 minutes to run.
When the analysis is finished, click Logs to close the Logs panel.