Quickstart Warp tutorial: Enter the study parameters

In this task, you enter the study settings, then run the analysis.

Material

  1. Click Material (Home tab > Molding Process Setup > Select Material).
  2. Verify that the Manufacturer is Training Materials and that the Trade Name is Training ABS 01 Unfilled VI(240)0053.
  3. Click OK.

Process Settings

  1. Click Process Settings (Home tab > Molding Process Setup panel > Process Settings).

    1. Ensure that the Melt temperature is 260° C.
    2. Ensure that the Mold-open time is 5 seconds.
    3. Ensure that the Mold-close time before injection is 0 seconds.
    4. Ensure that the Injection + Packing + Cooling time to 15 seconds.
    5. Ensure that the Mold temperature option is Averaged within cycle.
    6. Click Next.
    7. Ensure that the filling control is flow rate, and is 48 cm^3/s.
    8. Ensure that the Velocity/pressure switch-over is Automatic.
    9. Ensure that the Pack/holding control is %Filling pressure vs time with values of 0 80, and 10 80.
    10. Click Next.
    11. Ensure that Isolate cause of warpage is checked.
    12. Ensure that Consider corner effects is checked.
    13. Click Finish.
  2. Click Analyze (Home > Molding Process Setup > Analyze).

  3. Ensure a computer is selected. Typically the localhost is selected.

  4. Click Launch.

  5. When the analysis is finished, click Logs to close the Logs panel.