Quickstart Warp tutorial: Enter the study parameters
In this task, you enter the study settings, then run the analysis.
Material
- Click
(Home tab > Molding Process Setup > Select Material).
- Verify that the Manufacturer is Training Materials and that the Trade Name is Training ABS 01 Unfilled VI(240)0053.
- Click OK.
Process Settings
Click
(Home tab > Molding Process Setup panel > Process Settings).
- Ensure that the Melt temperature is 260° C.
- Ensure that the Mold-open time is 5 seconds.
- Ensure that the Mold-close time before injection is 0 seconds.
- Ensure that the Injection + Packing + Cooling time to 15 seconds.
- Ensure that the Mold temperature option is Averaged within cycle.
- Click Next.
- Ensure that the filling control is flow rate, and is 48 cm^3/s.
- Ensure that the Velocity/pressure switch-over is Automatic.
- Ensure that the Pack/holding control is %Filling pressure vs time with values of 0 80, and 10 80.
- Click Next.
- Ensure that Isolate cause of warpage is checked.
- Ensure that Consider corner effects is checked.
- Click Finish.
Click
(Home > Molding Process Setup > Analyze).
Ensure a computer is selected. Typically the localhost is selected.
Click Launch.