Transient Initial Condition

Description: Defines values for initial conditions of variables used in transient response analysis. Displacement, velocity, and acceleration may be specified at independent degrees of freedom.

Format:

Example:

Field Definition Type Default
SID Set identification number. Integer > 0 Required
Pi Grid point identification number. Integer > 0 Required
Ci Component number of global coordinate (up to six unique digits may be placed in the field with no embedded blanks). 0 ≤ Integer ≤ 6 Required
U0 Initial displacement. Real 0.0
V0 Initial velocity. Real 0.0
A0 Initial acceleration. Real 0.0

Remarks:

  1. Transient initial condition sets must be selected with the Case Control command IC = SID.
  2. If no TIC set id selected in the Case Control Section, all initial conditions are assumed zero.
  3. Initial conditions for coordinates not specified on TIC cards will be assumed zero.