X7035 FATAL ERROR: X7035 The energy balance calculation yielded an infinite (Inf) quantity. Exiting.
Cause: Something has gone wrong in the calculations and the energy balance has yielded an infinite (Inf) value. This indicates that the mesh has become horribly distorted.
Action: This typically happens when nonsensical loads have been applied to the model that cause it to deform beyond any reasonable expectations. While Autodesk Explicit has a full large-deformation formulation that allows extremely large strains, there are limits to how far you can distort a model (example: you cannot turn a part "inside-out"). Check the loads and boundary conditions to see if they are reasonable. Defining appropriate element deletion criteria can often fix this problem.
Remarks: