Change calculation settings to allow for wall, floor, and ceiling openings.
- Click Quantification tab
Roombook Extension panel
(Calculation Settings).
The Calculation Settings dialog opens.
- Make changes to the listed parameters as described in the table below.
- When complete:
- Click Restore Defaults to change the default settings of the standard listed at the top of the Calculation Settings dialog.
- Click Cancel to close the Calculation Settings dialog without making changes.
- Click OK to change the calculation settings as specified.
Note: The International Standard does not contain project standard specific calculation settings. This procedure and resulting settings are for the German VOB Standard only.
Name | Description |
---|---|
VOB - Wall Openings | |
Ignore openings | Either Yes (default) or No. Ignores wall openings up to a certain size during surface area calculation. |
Area - equal to or less than | Specifies the largest wall opening area to ignore. 2.5 m² is the default. |
VOB - Floor and Ceiling Openings | |
Ignore openings | Either Yes (default) or No. Ignores floor and ceiling openings up to a certain size during surface area calculation. |
Area - equal to or less than | Specifies the largest floor and ceiling opening area to ignore. 0.1 m² is the default. |