Share

Assign Volumetric Flow Rate Boundary Condition to Inlet

Click Boundary Conditions from the Setup tab:

boundary conditions

Select the inlet.

select inlet

Open the Boundary Conditions quick edit dialog in ONE of the following ways:

  • Click Edit from the context toolbar:

edit toolbar

  • Click Edit from the Boundary Conditions context panel:

edit bc

Type = Volume Flow Rate

Unit = m3/min

Volume Flow Rate = 0.2

volume flowrate

Click Apply.

Back | Next