Assign Volumetric Flow Rate Boundary Condition to Inlet
Click Boundary Conditions from the Setup tab:
Select the inlet.
Open the Boundary Conditions quick edit dialog in ONE of the following ways:
- Click Edit from the context toolbar:
- Click Edit from the Boundary Conditions context panel:
Type = Volume Flow Rate
Unit = m3/min
Volume Flow Rate = 0.2
Click Apply.