Issue:
User's have reported seeing the following warning message:Warning: Toolpath crosses rotary axis.
Causes:
There is no Clearance offset provided in the Radii tab under tool settings.Solution:
Follow these steps:- Right-click the toolpath.
- Click Edit.
- Select the Radii tab.
- Under Clearance offset, change the value of offset to be less than the inner radius offset.
Note: If the Inner Radius offset is set to zero, it will be necessary to give it an offset amount such as 0.1 or so.