Perform the Calculation

In the Calculation tab, you can set the values for compression spring calculation.

  1. In Calculation Options, select F, Assembly Dimensions -->d, L0, n, D from the Design Type drop-down menu.
  2. Select No Correction from the Method of Stress Curvature Correction drop-down menu.
  3. In the Loads region:
    • Set Min. Load to 500 N.
    • Set Max. Load to 800 N.
    • Set Working Load to 600 N.
  4. Click Calculate to perform the calculation.

    The program shows results on the right side of the Calculation tab. The inputs that fail the calculation appear in red (their value does not correspond with other inserted values or calculation criteria). Reports of the calculation are displayed in the Summary of Messages area, which appears after you click the chevron in the lower-right part of the Calculation tab.

  5. Click the Results command in the right upper corner to open the HTML report.
  6. Click OK.

Previous | Next