The following instructions describe how to perform an energy analysis using conceptual masses in Revit. Use these instructions to quickly create a baseline simulation that uses default energy settings. Then see the Energy Analysis using Conceptual Masses - Detailed Workflow to learn how to modify the conceptual mass model and its energy settings to refine the analysis.
1. |
Sign in to Autodesk 360 |
To use this feature, you must sign in to Autodesk 360. Click Sign in Sign in to Autodesk 360, and enter your Autodesk ID and password. |
2. |
Create a mass model. |
Create a mass model. You can load a mass family into a project for analysis or create an in-place mass directly in a project. |
3. |
Add mass floors. |
In the project environment, select the mass model, and add mass floors. |
4. |
Set Conceptual Masses as the basis of the Energy Analytical Model. |
Click Analyze tabEnergy Analysis panel Use Conceptual Mass Mode. |
5. |
Create the energy model. |
Click Analyze tabEnergy Analysis panelEnergy Settings. In the About Energy Settings dialog:
Click Analyze tabEnergy Analysis panel Enable Energy Model. |
6. |
Run the Energy Simulation. |
Display a 3D view of the mass model, and click Analyze tabEnergy Analysis panel Run Energy Simulation. |
7. |
Name the analysis and specify the Green Building Studio project. |
In the Run Energy Simulation dialog, specify a name for the analysis, and select whether to create a new or use an existing Green Building Studio project. Then click Continue. |
8. |
Simulated elements display. |
The current view displays mass zones and mass shades, and it temporarily dims elements that are not included in the simulation. |
9. |
Click the simulation name. |
When the analysis is complete, an alert displays. Click the analysis name in the alert to view the simulation results. Or click Analyze tabEnergy Analysis panel Results & Compare, and select the analysis from the project tree. |
10. |
Review the simulation results. |
In the About Results and Compare dialog, view the analysis results. Tip: Use the Settings tab to select the charts to include in the results and to configure the display of energy analysis data on the Results tab.
|
11. |
Make changes, simulate, and compare. |
Modify the mass model and energy settings as needed. Then repeat steps 4-7 to run a simulation on the modified model. For a side-by-side comparison of simulation results, select multiple analyses and click Compare on the toolbar. |