Graphical scaling requires 3 clicks: the first click determines the origin, and the next 2 clicks define the scale vectors. Revit calculates a scale factor by determining the ratio of the lengths of the 2 vectors. For example, suppose you sketch a first vector that is 5 feet and a second vector that is 10 feet. This creates a scale factor of 2. As a result, the elements become twice their original size.
Be sure to select only supported elements, such as walls and lines. The Scale tool is unavailable if your entire selection contains just one non-supported element.
The origin is the point from which the size of the element will change. The cursor snaps to various references. Press Tab to change the snap points.
The selected element scales so that the ends of vector 1 now coincide with those of vector 2.
Defining the first scale vector
Defining the second scale vector
The scaled element