Assign Water to Flow Volume and Caps

Questions about applying settings?

Hide the pipe wall.

Select the caps and the flow volume.

Open the Materials quick edit dialog in ONE of the following ways:

On the Material quick edit dialog, Type = Fluid

Name = Water

To allow the density to vary, click Set... on the Environment line. On the Material Environment dialog, select Variable, and click OK.

Click Apply.

Note: This is not a buoyancy analysis, but allowing the density to vary will make the solution more stable.

Back |Next