Detects problems related to wire numbers in the active project and displays a report of them.
FindDrawing Audit identifies and cleans up some of the problems that can affect an AutoCAD Electrical drawing. Save the error report file for reference or surf the file to view and correct errors.
Audit drawing or project |
Specifies to run the audit on the active drawing or selected drawings in the active project. |
Previous |
Redisplays the last audit report that was run. You can then surf to the performed function, save the report, or print the report for reference. |
Surf |
Goes to the error location within the drawing where the error occurred and was fixed. |
After you click OK, you can select the type of drawing audit to run. If you selected to audit the project, select the drawings in the active project to audit, and click OK. |
|
Wire gap pointers |
Looks for problems related to missing wires which were connected through gap pointers. |
Bogus wire number and color/gauge label pointers |
Looks for and cleans up wires pointing to nonexistent wire numbers (it is the opposite of wire number floaters). Also looks for bad color/gauge label pointers. |
Zero length wires |
Looks for and erases zero length line entities on the wire layer. |
Wire number floaters |
Looks for and erases wire numbers that are not linked to a wire network (for example, the wire was manually erased but wire number remains). |
Show wires (mark in red) |
Draws an outline around each wire entity.