Input variables, expanded

Some processing conditions, for example filling control, have several options associated with them. The list that appears in Variables tab of the DOE builder will change depending on which option in the Process Settings has been selected. These details are explained in the table below.

The values shown in the DOE builder are brought in from the Process Settings. To change values in the DOE builder, go to Process Settings and make the changes there.

Processing Condition variables Comment
% Ram speed vs % Stroke profile Min and Max values editable in the DOE Builder. X and Ymin=0, X and Ymax=100 depending on the values set in the Process Settings
Compression Settings profile Min and Max values editable in the DOE Builder. X and Ymin=0, X and Ymax=100 depending on the values set in the Process Settings
Cooling time Only available if NOT set to automatic in base study
Curing temperature  
Curing time  
Filling control  
Automatic Only available if NOT set to automatic in base study
Fill time  
Flow rate  
Absolute ram speed profiles  
Relative ram speed profiles Min and Max values editable in the DOE Builder. X and Ymin=0, X and Ymax=100 depending on the values set in the Process Settings
Reference Could be flow rate or injection time, indicated by parameter name
Stroke volume, machine screw diameter Only available if stroke volume is set to specified, NOT automatic
Stroke volume, starting ram position Only available if stroke volume is set to specified, NOT automatic
Initial bubble radius  
Initial encapsulant conversion  
Initial encapsulant temperature  
Initial gas concentration  
Injection+Packing+Cooling time  
Melt initial conversion  
Melt temperature  
Mold open time  
Mold surface temperature  
Nominal injection time  
Number of cells per volume  
Pack/holding control  
% Filling pressure vs. time Profile, Min=0 for X and Y; Max=300 for X and 200 for Y
Packing pressure vs. time Profile, Min=0 for X and Y; Max=300 for X and 500 for Y
Hydraulic pressure vs. time Profile, Min=0 for X and Y; Max=300 for X and 50 for Y
% Maximum machine pressure vs. time Profile, Min=0 for X and Y; Max=300 for X and 100 for Y
Press compression force cap  
Press compression speed vs. distance  
Press compression time  
Press open distance  
Press waiting time  
Substrate temperature  
Velocity/pressure switch-over by  
by % volume  
by injection pressure  
by pressure at a control point Node defined in base study, only field for pressure
pressure  
Velocity/pressure switch-over  
Automatic Only available if NOT set to automatic in base study
by % volume filled  
by ram position  
by injection pressure  
by hydraulic pressure  
by clamp force  
by pressure control point Node defined in base study, only field for pressure
by injection time  
Volume filled at start of foaming