This group contains the structural feature classes that make up the structural network plus some additional structural feature classes. The Structural_CONN feature class stores flow and connectivity information for the logical topology.
Feature class | Type | Table name and description |
---|---|---|
Access Point | Attribute | EL_ACCESS_POINT. A structure that provides access to electric facilities. |
Anchor | Attribute | EL_ANCHOR. An anchor associated with a structure. This feature class includes a predefined label feature class (EL_ANCHOR_TBL). Not included in the structural network. |
Antenna | Attribute | EL_ANTENNA. An anchor associated with a structure. This feature class includes a predefined label feature class (EL_ANTENNA_TBL). Not included in the structural network. |
Arrestor | Attribute | EL_ARRESTOR. An anchor associated with a structure. This feature class includes a predefined label feature class (EL_ARRESTOR_TBL). Not included in the structural network. |
Conductor Hold | Point | EL_CONDUCTOR_HOLD. An element that supports the conductor against wind. |
Connector | Point geometry | EL_CONNECTOR. This feature class connects two segments. It includes a predefined label feature class (EL_CONNECTOR_TBL). |
Duct | Line geometry | EL_DUCT. A duct contains one or more conductors and is used to protect the conductors when placed underground. EL_DUCT_AREA is used for ducts in multi conductor mode. EL_DUCT_CONDUCTOR manages the connections between ducts and conductors. EL_DUCT_DUCT manages the connections between ducts within ducts. EL_DUCT_MARKER marks the end of a duct. |
Feeder Pillar | Point geometry | EL_FEEDER_PILLAR. A metal cabinet with opening doors. This feature class includes a predefined label feature class (EL_FEEDER_PILLAR_TBL). |
Fuse Bank | Point geometry | EL_FUSE_BANK. This feature class includes a predefined label feature class (EL_FUSE_BANK_TBL). |
Guy | Line geometry | EL_GUY. A wire that supports a pole. It acts against the tension provoked by the cables attached to the pole. Not included in the structural network. |
Handhole | Point geometry | EL_HANDHOLE. A small underground access point. This feature class includes a predefined label feature class (EL_HANDHOLE_TBL). |
Intermediate Structure | Point geometry | EL_INTERMEDIATE_STRUCTURE. This class participates in the EL_STR (STRUCTURAL) topology and is used as an intermediate topological point for placing structural points where there is a need for a generic structural point feature to join two segments, for example where a device might need to be added without a specific structural feature. |
Internal Cell | Polygon geometry | EL_INTERNAL_CELL. |
Junction Cabinet | Point geometry | EL_JUNCTION_CABINET. This feature class includes a predefined label feature class (EL_JUNCTION_CABINET_TBL). |
Link Box | Point geometry | EL_LINK_BOX. A sunken box with a concrete lid at ground level. This feature class includes a predefined label feature class (EL_LINK_BOX_TBL). |
LV Board | Point, line, and polygon geometry | EL_LV_BOARD. LV Distribution busbar mounted on the substation wall. This feature class includes a predefined label feature class (EL_LV_BOARD_TBL). |
Manhole | Point geometry | EL_MANHOLE. An underground access point. This feature class includes a predefined label feature class (EL_MANHOLE_TBL). |
Pad | Point geometry | EL_PAD. A structure that is made of poured concrete, laid over a gravel base, upon which electric facilities (most commonly transformers) are placed. This feature class includes a predefined label feature class (EL_PAD_TBL). |
Pathway | Attribute | EL_PATHWAY. This feature class stores information about the segment feature classes in the electric network. Use the Electric Explorer to manage the network. Do not edit these tables manually. |
Pedestal | Point geometry | EL_PEDESTAL. This feature class includes a predefined label feature class (EL_PEDESTAL_TBL). |
Pole | Point geometry | EL_POLE. Supports overhead devices in the electrical system. This feature class includes a predefined label feature class (EL_POLE_TBL). |
Structure Decoration | Point, line, and polygon geometry | EL_STRUCTURE_DECO. Not included in the structural network. This feature class is used for visualization of structural details, such as a footprint. |
Substation | Point geometry | EL_SUBSTATION. A walled structure where voltage transformation takes place. The substation itself is not connected to the electric network. It is part of the structural network. This feature class includes a predefined label feature class (EL_SUBSTATION_TBL). |
Tower | Point geometry | EL_TOWER. A special type of pole structure, characterized by its size and construction type. It usually supports high voltage conductors. This feature class includes a predefined label feature class (EL_TOWER_TBL). |
Transformer Bank | Point geometry | EL_TRANSFORMER_BANK. This feature class includes a predefined label feature class (EL_TRANSFORMER_BANK_TBL). |
Transformer Station | Point geometry | EL_TS_STATION. This feature class includes a predefined label feature class (EL_TS_STATION_TBL). |
Vault | Point geometry | EL_VAULT. A walled structure that can be underground or on a slab and which houses electric devices. This feature class includes a predefined label feature class (EL_VAULT_TBL). |
Warning Light | Point geometry | EL_WARNING_LIGHT. Warning light associated with a structure. This feature class includes a predefined label feature class (EL_WARNING_LIGHT_TBL). Not included in the structural network. |