This menu controls which components are visible, and therefore editable, in the graph view of the Graph Editor. This is useful for controlling the amount of information displayed in the graph view, as well as specifying which of the animation curve components are available for editing.
When framing the desired range, the Graph Editor may scale the area in the graph view horizontally and vertically to display the desired range.
Clip Time lets you view the clip animation curves at their position and scale in the Trax Editor.
Adjusts the graph view to fit all animation curves in the window.
Adjusts graph view to fit selected animation curves or curve segments in the window.
Adjusts the graph view to fit the playback range in the window.
If you change the view in the Graph Editor and want to shift the view so the current time is in the middle of the editor, select Center Current Time from the View menu.
Automatically adjusts the graph view to fit the display of the animation curves associated with a selected object or objects.
To edit these types of animation, you must transform them into animation curves by performing a Bake Channel.
Any numeric attribute can drive Show Results. This is useful for looking at animations driven by anything other than a single animation curve. Select Show Results > to open and set the Show Results Options.
Samples the result of what one pixel represents in time. This may not accurately reflect the actual animation (especially if you are zoomed out). However, by adjusting the sampling rate, you can choose between curve accuracy and update time. A higher sampling rate means more accurate representation but longer computation time.
When screen based sampling is turned on, the sample rate specifies the number of pixels per sample. When it’s turned off, the sample rate specifies the number of frames or current time units per sample.
Turning this on causes the graph view to display the original shape of edited curves. Selecting the checkbox at the end will display the Show Buffer Curve Options window.
You can customize the default Buffer Curve and Buffer Curve key colors in the Preferences menu Color Settings (Available only with the Modern Graph Editor.)
Selecting the Select param curves following key deletion checkbox will turn on the auto-selection of curves. The default (checkbox selected) behaviour is consistent with previous versions of Maya.
Lets you set the viewable status of keys.
Customize the default key color in the Preferences menu Color Settings. (Available only with the Modern Graph Editor.)
Sets keys to be visible at all times in the graph view of the Graph Editor.
Hides keys in the graph view. Because keys are no longer available for picking, you can no longer edit them.
Sets keys to be available only when you select the curve they are associated with.
Lets you set the viewable status of tangents. (In order to operate on a component of a tangent, you must make it available by being designated as viewable.)
Customize the default tangent color in the Preferences menu Color Settings. (Available only with the Modern Graph Editor.)
If you wish to operate on tangents and you’ve disabled curves and keys in the Select menu of the Graph Editor, set the visibility of tangents to Always so they are available for selection.
Setting the viewable status of tangents to Never hides tangents in the graph view. Because tangents are no longer available for selection, you can no longer edit them.
When the viewable status of tangents is set to On Active Keys, tangents are available only when you select their associated curve or curve segment.
Infinity turns on or off the display of the animation curve extrapolated outside the first and last keys of the curve.
The curves before the first key and after the last key will be constant by default.
When on, the graph view displays individual curves in a stack, rather than displaying all curves overlapping. When Stacked View is active, each curve displays with its own value axis, normalized between 1 and -1 by default.
When using the Scale Keys Tool or the Lattice Deformer Keys Tool with the Stacked View active, you can only modify the time value.
When on, this option scales down large key values or scales up small key values to fit within a -1 to 1 range. When animation curves are normalized, they are adjusted to fit within the range of normalization.
Curve normalization is useful when you want to view, compare, or edit animation curves that are related (such as rotation and translation curves), but have drastically different ranges. For example, with curve normalization you can compare all the translation and rotation animation curves for an object.
When you turn Display Normalized off, the curves revert to a non-normalized state, back to their original ranges.
Animation curves that are normalized appear thicker than other curves in the Graph Editor.
Limitations: Curve normalization does not work with the following types of curves:
Available only when Display Normalized is on. Select this option to renormalize the curves displayed in the graph view.
Curves are automatically renormalized when you turn on Display Normalized or the active curve list changes.
You can also quickly renormalize curves by selecting the Renormalize icon in the Graph Editor toolbar.
Lets you toggle between the standard Graph Editor toolbar with a full set of curve editing and display options, or a more streamlined version of the toolbar with only select editing and display options. If you primarily use Maya as part of a suite of Autodesk applications, you may prefer to disable Classic Toolbar and use a more simplified interface in the Graph Editor, more consistent with the other products in your suite.