Use Parts to assess results on selected parts. Results Parts can also be designated as Summary Parts, and used in the Decision Center to assess Critical values. 
An example of using a Result Part is an electronic power inverter. The temperature on several components cannot exceed a value of 60°C. After the Scenario is run to convergence, obtain the temperature on each component using the Part dialog. 
To compare the resultant temperature on a component from several Scenarios in the Design Study, make them Summary Points, and compare their values in the Decision Center. 
 
	  
		Extract results from: 
	 
 
	 -  Fluids 
		
 
- Solids 
		
 
-  Internal fans 
		
 
- Compact thermal models 
		
 
- Heat exchangers 
		
 
 
	  
		To view results 
	 
 
	 - Click 
		  Results (tab) > 
		  Results Tasks (panel) > 
		  Parts to open the Parts dialog. 
		
 
- Select parts of interest from the model. 
		
 
- Click 
		  Calculate either on the 
		  Parts dialog or from the 
		  Parts context menu. 
		
 
 
	 Note: To change units, make the part a Summary Part, and modify the units in the 
		
Summary Values table. 
	 
 
 
	 Note: Part-based temperatures are computed using volumetric temperature averaging. 
	 
 
	  
		To designate a part as a Summary part 
	 
 
	 - Either click 
		  Make Summary on the 
		  Parts context panel or check the box adjacent to the part name on the 
		  Parts dialog. 
		
 
 
To view the list of Summary parts
- Click the Summary parts tab on the Parts dialog. 
 
Note: The Part is listed as a Summary Part in the Decision Center. Results on the part from each scenario are listed in the Critical Values table of the Output Bar. 
For more about using a boundary condition to define a Summary Part...
To delete a Summary Part:
- In the Decision Center, right click on the Summary Part. 
 
- Click Remove. 
 
Note: This removes the Summary Part designation from the part; it does not delete the part from the model. 
Related Topics