The
Options
Factory Annotations tab controls asset tag and descriptor text font, height, and placement in AutoCAD Factory. The changes you make affect only assets that are subsequently placed (dragged and dropped) from the
Asset Browser into the AutoCAD layout. Your changes do not affect any of the asset tags and descriptors that appear as a result of syncing from Inventor.
If you wish to make changes to the asset tag and descriptor settings from synced assets, use the AutoCAD
STYLE command to change the annotation font. To change the attribute text height, use the
EATTEDIT command.
Note: Once Inventor is restarted, the annotations settings on the AutoCAD
Factory Annotations tab are automatically synced with the annotations settings on the
Annotations tab of the
Factory Options dialog box in Inventor Factory.
To access the
Factory Annotations options:
- At the bottom of the
Application menu
, click
Options.
- In the
Options dialog box, navigate to the
Factory Annotations tab.
- On the
Factory Annotations tab, select the desired font from the
Font drop-down list.
- Set the text height in the
Height text box. The default text height is 0.125 inches (3mm). Be sure to set the text height to an appropriate size to reflect the drawing/plot scale of the 2D layout.
- Next, determine text placement settings.
The
Below setting places the text away from the asset or inserted model.
Center places the text in the center of the asset or inserted model. The graphic image in the dialog box reflects your placement changes.
Align Left lines the description text up with the left side of the asset text.
Align Right lines the text up with the right side of the asset text.
Center aligns the text in the middle.
- Select the layer in which you want each text type to appear. Asset Tag, Property, and Descriptor layers are always available. Additional options might also appear if you selected the
Load Layers from File option in the Factory Assets tab. See
Setting Factory Asset Defaults for details about the Load Layers option.
- Select
Include Property Name to display the name of an asset property in addition to its value. For example, the Factory property heading
WEB Link: will appear in front of the web address defined for the asset if this option is selected. If left unchecked, only the web address will appear without the heading.
For information about adding a tag to a placed asset or a descriptor when publishing an asset see
Adding Asset Tags and Descriptors