Assign a start node and end node controller to each dispensing path. You can create multiple dispensing paths.
- Click
() to open the
Set Dispensing controller dialog.
- In the
Set Dispensing controller dialog, select the start node controller you want for this dispensing path, then click on your model to select the start node of the dispensing path. This node must already have an injection cone on it. Rotate the model and zoom in as necessary until the controller glyph appears on the node.
A cross appears on the selected node. The orientation of the cross is irrelevant, but confirm that the center of the cross is superimposed on your selected start node.
- In the
Set Dispensing controller dialog, select the end node controller you want to use, then click on your model to select the end node of your dispensing path. This node must also already have an injection location on it. Rotate the model and zoom in as necessary until the controller glyph appears on the node.
A cross appears on that node. The orientation of the cross is irrelevant, but confirm that the center of the cross is superimposed on the selected end node.
- Repeat for each dispensing path, then close the
Set Dispensing controller dialog.
- Click
() and select
Perform dynamic analysis to activate dynamic dispensing, then click
OK.
- Once you have set all your other processing conditions, click