Pump properties dialog

Applies to 2018.3 Update and later

This dialog is used to view, edit, or import the pump curve profile, when running a Coolant Flow analysis.

To access this dialog, select the Pump element, then either select Edit (Geometry tab > Properties panel > Edit), or right-click and select Properties from the drop-down menu. Select the Pump data tab, and click Edit associated with the pump controller.

Dialog element Explanation
Pump Curve profile

Pump curve profiles of force (head) vs flow are provided by the manufacturer, for a given fluid, often water. To convert this to pressure for your fluid, you need to know the specific density of your fluid, apply the equation, and convert to MPa:

[Head (ft) / 2.31] x sp.gr = pressure (PSI)

If you don't have pump curve data, a default pump curve is provided and selected by default, but your simulation your results are more accurate if you use your own pump performance data.

Import Profile

To help speed up data entry and minimize errors that might occur during manual data entry, import tabulated data from *.csv files.

Plot Profile

Check the profile by clicking the Plot Profile button.