Applies to 2017.3 Update and later
You can create a valve gate controller, or edit an existing controller and save it under a new name.
On export, valve gate controller information created within a study is shared with the study file. Settings that are obtained from the valve gate controller database cannot be viewed in an exported study file unless the valve gate controller database is also shared.
To create a valve gate:
Widget | Explanation |
---|---|
Time | Select whether the valve gate is initially open or closed, then enter the times (sec), from the start of injection, at which further opening/closing of the valve gate should occur. If you choose initially Open, the only option in Valve gate open/close times table is to close it again. |
Flow Front | Select whether the triggering location is the gate node or another specified model node. If required, enter a delay time before the valve gate opens, starting from the instant when the flow front passes the triggering location. |
Pressure | Select whether the valve gate is initially open or closed, select whether the triggering location is the gate node or another specified model node, then enter the pressure values at which further opening/closing of the valve gate is to occur. |
% Volume | Select whether the valve gate is initially open or closed, then enter the %volume filled values at which further opening/closing of the valve gate is to occur. |
Ram Position | Select whether the valve gate is initially open or closed, then enter the ram position values at which further opening/closing of the valve gate is to occur. |