Mesh Repair Wizard - Settings for 3D mesh repair

To access this dialog, once your 3D model is meshed click Mesh Repair Wizard (Mesh tab > Mesh Edit panel > Mesh Repair Wizard) and then click Settings.

Dialog element Explanation
Minimum number of required layers Enter the criterion for refinement diagnostic. The default value is 6.
Maximum allowed edge length ratio (internal/surface) Enter the criterion for long edges diagnostic. The default value is 3.
Maximum allowed volume ratio to average volume Enter the criterion for large volume diagnostic. The default value is 20.
Search for tetras with aspect ratio higher than Enter the criterion for aspect ratio diagnostic. The default value is 100.
Search for flat tetras with interfacial angle larger than (degrees) Enter the criterion for large angle diagnostic. The default value is 178.
Restrict to visible entities Forces the Mesh Repair Wizard to ignore elements that are on hidden layers.
Save Current Values Use the values defined as your default settings. These values only last for the current session. Other studies can load and use the saved values.
Load Saved Values Repopulate the target values with values saved earlier in the session.