Use the Configuration dialog to define parameters applied during the verification of a steel member according to Eurocode 3. 
  
 
		- Access 
			 
 
-  
				
- In the 
					 Steel/Aluminium design layout, click 
					 Configuration in the Calculations dialog. 
				  
 
 
			  
 
	  
Dialog elements
 
		 
		 
		
 
		- Calculation points 
			 
 
- Specify a number of calculation points or characteristic points: 
				
- Enter the number of points that are evenly distributed along the member length. 
				  
 
- Select Characteristic points and then click Options to open the 
					 Calculations in Characteristic Points dialog. 
				  
 
 
			  
- Calculation parameters 
			 
 
-  
				
- Efficiency ratio 
					 
 
- Defines the coefficient by which the plasticity limit will be multiplied. This ratio increases or decreases the plasticity limit. 
					 
 
- Maximum slenderness 
					 
 
- Verifies the slenderness of the member. 
					 
 
- Components of complex members are not taken into account 
					 
 
-  Select this option to ignore complex members components for the members during the calculations. 
					 
 
- Elastic analysis 
					 
 
- Classifies the cross-section as a class 3 cross-section. 
						
Note: The Elastic analysis option does not apply to class 4 sections. These sections are not reclassified to class 3 after selecting this option. 
						
 
					  
- Deselect this option if you want to check each cross-section automatically. During this process, 
						Robot uses the cross-section class to calculate the strength of the section in the plastic state (class 1 and 2) or the elastic (class 3 and 4) state. 
					 
 
- Shear verification in the elastic state (6.2.6) 
					 
 
- Checks he shear stresses in the elastic state according to point 6.2.6(d) of the code without considering the partial plastic redistribution of shear stresses. 
					 
 
 
			  
- Methods of calculation of interaction factors kij 
			 
 
- Contains the list of calculation methods of the interaction factors kij. 
			 
 
- These calculation methods are used to verify the global stability of a member under complex loading (compression and bending). These factors are included in the verification formulas (6.61 and 6.62) given in section 6.3.3.(4) of the EN 1993-1-3:2005 code. 
				
-  
					 Method 1 [Annex A]: Calculates the kij factors according to Annex A. 
				  
 
-  Method 2 [Annex B]: Calculates the kij factors according to Annex B. 
				  
 
 
			  
- Fire analysis 
			 
 
- Allows design and verification of steel members with user-defined sections according to the specified guidelines: 
				
- European code EC3 EN 1993-1-2:2005 
				  
 
- Official document 3 of the ECCS Technical Committee 'Model Code of Fire Engineering' - First Edition, May 2001. 
				  
 
 
			  
- The parameters of the fire analysis are defined in the 
				Member definition - fire resistance parameters dialog. It is possible to select a verification criterion used during the fire verification. There are three verification methods available. 
				
-  Resistance domain - verification according to section 4.2.3 of the EN 1993-1-2 code or sections III.5.1-7 of the document 3 of the ECCS Technical Committee. 
				  
 
-  Temperature/time domain - verification according to point 4.2.4 of the EN 1993-1-2 code or sections III.5.8 of the document 3 of the ECCS Technical Committee. 
				  
 
-  Time domain - verification according to point 4.2.4 of the EN 1993-1-2 code or sections III.5.8 of the document 3 of the ECCS Technical Committee. 
				  
 
 
				Note: Selecting the Fire calculations option excludes structure analysis in the serviceability limit state. Therefore, the Limit state - Serviceability option in the Calculations dialog will not be available. 
				
 
			  
- Exclude internal forces from calculations 
			 
 
- Opens the 
				Internal Forces Not Taken into Consideration dialog which allows you to define the limit values of internal forces. 
			 
 
- During the analysis, any force value that is negligible for a specific section will be disregarded. 
			 
 
- Units of results 
			 
 
- Specify if you want to use the selected steel code units or the units used in 
				Robot in your member design results. 
			 
 
- Camber 
			 
 
- Select 
				Take the deflections from the following case into consideration, and then select the load case for which the displacements defined will be treated as structure camber.