Use this procedure to create a stair interference area in a slab. When you add an interference condition between a stair and a slab, a box is cut out around the stair based on the specified headroom height and left and right side clearances for straight and multi-landing stairs or inside and outside clearances for spiral and U-shaped stairs.
Specifying the left and right side clearances for a slab interference condition
Specifying the inside and outside clearances for a slab interference condition
If you want to… | Then… |
---|---|
specify the height above the treads for the interference condition | enter a value for Headroom height. |
specify the left and right side clearances for the interference condition for straight and multi-landing stairs | enter values for Left and Right Clearance. |
specify the inside and outside clearances for the interference condition for spiral and U-shaped stairs | enter values for Inside and Outside Clearance. |
Creating a slab and stair interference condition