Modify project settings for cross-referencing.
FindAny new drawing files created within the project are saved with the project default settings for cross-referencing.
In the Project Manager, right-click the project name, and select Properties. Select the Cross-References tab.
Defines the cross-reference annotation format. One replaceable parameter, %N, must always be part of the cross-reference format string. A typical format string might be the %N parameter. Use Same Drawing for on-drawing references and Between Drawings for off-drawing references. You can use the same format for both.
Real-time signal and contact cross-referencing between drawings |
Automatically updates relay and wire source and destination symbols cross-referencing across multiple drawings.
Note: If this option is not selected, run the Component Cross-Reference command and the Update Signal References command to update component and signal cross-referencing.
|
Peer to Peer |
Includes cross-discipline peer components in the cross-referencing. Example: schematic - pneumatic. |
Suppress Installation/Location codes when matching the drawing defaults |
Suppresses combined tag prefixes if the values match the drawing property values. |
There are different styles of cross referencing AutoCAD Electrical toolset supports:
Text Format |
Displays cross-referencing as text with any string as a separator between references on the same attribute. |
Graphical Format |
Displays cross-referencing using the AutoCAD Electrical toolset graphical font or using contact mapping edit boxes while displaying each reference on a new line. |
Table Format |
Displays cross-referencing in a table object. |
Setup |
Displays a dialog box for setting the display defaults for the selected component cross-reference display format. |