Prepare the pipe network for flow rate analysis and sizing
Before analyzing and sizing the pipe network, you must first set up the pipe network and create catchments or determine the known flow. For more information about prerequisites, see
About Analyzing and Sizing a Gravity Pipe Network.
To analyze and size a pipe network for specified rainfall data
Click the
Analyze tab Design panel Analyze Gravity NetworkFind.
Select the pipe network you want to analyze. You can select the network in the drawing or press Enter and select the pipe network from the Select Pipe Network dialog box.
After you select the pipe network, the
Analyze Gravity Network dialog box is displayed.
Note: If the selected pipe network is data-referenced, the energy and hydraulic grade lines can be computed, but analysis results cannot be applied to the pipe network.
On the
General page, review and specify the following items:
Analysis types to run
Outfall part
Tailwater condition
Rainfall data
Click
Settings to open the Settings page where you can specify settings to use in the analysis.
Click
Network Details to open the Network Details page where you can specify settings and values for the pipes and structures.
Note: To edit multiple rows in a column, hold down the Ctrl or Shift keys when selecting the rows and then keep the Shift key pressed when you click the column.
Click the Analyze button at the bottom of the dialog box to process the analysis.
On the
Results page, you can review the results and preview the changes in profile view, you can output a report of the results to a .csv file, and you can apply the results to the pipe network.