Lead in/out plane

The arcs and ramps are measured relative to one of the following options:

Normal to surface: Lead in/out moves are relative to the surface normal.

Horizontal: Moves are relative to a horizontal plane. Directions of the ramp could be right or left.

Horizontal left: This setting is most useful for uni-directional paths. It ensures a consistent left ramping.

Horizontal right: This setting is most useful for uni-directional paths. It ensures a consistent right ramping.

Vertical: Moves are relative to a vertical plane.

Default: The default for z-level finish is Horizontal, and Vertical for all others.