*FSBT: Floating Substrate Type

*FSBT

i1

*FBST controls the boundary conditions during the mechanical analysis before and after the simulated removal of the built component and the build plate. i1 is set to either 0 or 1, 0 being the default.

When i1 is set to 0:

Before build plate removal: The bottom of the substrate is fixed in z and a small circle in the center of the substrate base is fixed in x,y, and z.

After build plate removal: A small circle in the center of the build plate base is fixed in x,y, and z.

When i1 is set to 1:

Before build plate removal: The bottom of the substrate is fixed in z and a single element in the center of the substrate base is simply supported.

After build plate removal: A single element in the center of the substrate base is simply supported.

Required cards: *FSUB