You can add columns such as line number or COG to the ortho BOM table in an ortho drawing.
- Click
- In the Table Setup dialog box, click Add Column.
- The Select Class Property dialog box, under Class list, click Pipe Run Component.
- Under the Property list, click Line Number Tag.
- Click OK to close the Select Class Property dialog box.
- Under Table Layout, in the Show Column row, select Line Number Tag column.
Note: If you do not select the column, it is removed from the list.
- Do one of the following:
- To create an ortho BOM table, click Bill of Materials and specify the table location.
- To update an existing BOM, click Update Bill of Materials.
The line number tag displays.