The comma-separated value data file specifies the description of each harness object to import into the Cable and Harness Library. It uses a locale-specific list separator (typically a comma) for the column delimiter. Each row in the wire data file represents the data used to generate a new library wire. For cable data files, each row represents a cable wire with a Cable Name property that is a reference to the corresponding cable definition. Cable properties are imported to the cable definition with the provided Cable Name. The Conductor ID and Wire Name reference describe a cable wire in the cable definition, thus the cable wires must already exist in the library or wires must be imported before importing the cable definitions.
For export of library data, a data file with the same format is created, except that required properties need not be exported. The data exported is determined by the selected configuration file.
The order of the properties is defined by the list in the third row of the configuration file. Comment lines are specified with a preceding // and are ignored during import.
For each wire, the following information is required:
Wire Name |
The unique name given to the library wire. |
Appearance |
An appearance name that determines the appearance in which the wire is drawn in the graphics window. The appearance must match one of the predefined appearances listed in the harness assembly template. Other appearances can be created and added to the template. If the appearance does not match a predefined appearance, the wire is not imported. |
Outer Diameter |
The wire's outer diameter. |
Other guidelines include the following:
For each cable, the following information is required:
Cable Name |
The unique name given to the library cable. |
Outer Diameter |
The cable's outer diameter. If this value is blank, then the value is calculated from cable wires. |
Wire Name |
The name of the library wire associated with the cable wire. The library wire must exist or the cable wire is not imported. |
Conductor ID |
The unique identifier for the cable wire within the cable. |
Other guidelines include the following:
For each splice, the following information is required:
Splice Name |
The unique name given to the library splice. |
Other guidelines include the following:
For each ribbon cable, the following information is required:
Raw Ribbon Cable Name |
The unique name given to the library raw ribbon cable. |
Number of Conductors |
The number of conductors that are included in the selected raw ribbon cable. |
Pitch |
The distance increment of the conductors in the selected raw ribbon cable. |
Height |
The height or thickness for the selected raw ribbon cable. |
Width |
The width for the selected raw ribbon cable. |
Other guidelines include the following:
For each terminal, the following information is required:
Terminal Name |
The unique name given to the library cable. |
Other guidelines include the following:
For each seal, the following information is required:
Seal Name |
The unique name given to the library seal. |
Other guidelines include the following:
For each plug, the following information is required:
Plug Name |
The unique name given to the library plug. |
Other guidelines include the following:
For each label, the following information is required:
Label Name |
The unique name given to the library label. |
Height |
The height of the label's printable area. |
Width |
The width of the label's printable area. |
Other guidelines include the following:
For each loom, the following information is required:
Loom Name |
The unique name given to the library loom. |
Appearance |
An appearance name that determines the appearance in which to draw the segment to which the loom is assigned. It is typically the appearance of the segment or the loom. The appearance must match one of the predefined appearances listed in the harness assembly template. Other appearances can be created and added to the template. If the appearance does not match a predefined appearance, the loom is not imported. |
Thickness |
The loom's thickness. |
Other guidelines include the following:
For each custom virtual part, the following information is required:
Virtual Part Name |
The unique name given to the custom library virtual part. |
Other guidelines include the following:
Sample wire file
The following file is set to import the listed wires into the Cable and Harness Library with the required properties, and with the Part Number and Gauge properties.
//Wire Name,Appearance,Outer Diameter,Category,Part Number,Gauge
24AWG-BLK,black,0.024,Generic,24AWG_BLK,24
24AWG-BRN,brown,0.024,Generic,24AWG_BRN,24
24AWG-RED,red,0.024,Generic,24AWG_RED,24
24AWG-YEL,yellow,0.024,Generic,24AWG_YEL,24
24AWG-ORG,orange,0.024,Generic,24AWG_ORG,24
24AWG-GRN,green,0.024,Generic,24AWG_GRN,24
24AWG-BLU,blue,0.024,Generic,24AWG_BLU,24
See the corresponding configuration file if desired.
Sample cable file
The following file is set to import the listed cables into the Cable and Harness Library with the required properties.
//Cable Name,Category,Part Number,Outer Diameter,Conductor ID, Wire Name
Belden 4C 22AWG,Belden,9794,0.2,1,22GRN
Belden 4C 22AWG,Belden,9794,0.2,2,22RED
Belden 4C 22AWG,Belden,9794,0.2,3,22YEL
Belden 4C 22AWG,Belden,9794,0.2,4,22BLK
Sample splice file
The following file is set to import the listed splices into the Cable and Harness Library with the required properties.
//Library Name, Category,Part Number,Embedded Length, MyCustom
Splice_L,Size,SP_L_001,0.3in,1s,a,a,a
Splice_M,Size,SP_LM001,0.32in,12,a,a,a
Splice_LS,Size,SP_S_001,0.31in,13,a,a,a
Sample terminal file
The following file is set to import the listed terminals into the Cable and Harness Library with the required properties.
//Name,Category,Part Number,Min gauge, Max gauge, gauge type
Female_18-24AWG_Tin,Series_1000,Term-1001,24,18,Range
Female_16AWG_Tin,Series_1001,Term-1002,,16,Fixed
Male_18-24AWG_Tin,Series_1000,Term-1003,24,18,Range
Male_16AWG_Tin,Series_1001,Term-1004,,16,Fixed
Sample seal file
The following file is set to import the listed seals into the Cable and Harness Library with the required properties.
//Name,Category,Part Number,Min Outer Diameter,Max Outer Diameter,Diameter type
Seal_18-22AWG,Series_1001,SL-1002,0.5735,0.723,Range
Seal_16AWG,Series_1001,SL-1001,,0.8282,Fixed
Sample plug file
The following file is set to import the listed plugs into the Cable and Harness Library with the required properties.
//Name,Category,Part Number
Plug_Series_1000,Series_1000,PL-1001
Plug_Series_1001,Series_1001,PL-1002
Sample label file
The following file is set to import the listed labels into the Cable and Harness Library with the required properties.
//Name,Category,Part Number,Height,Width
Wire_Label,Clear,LB_1001,0.25,0.5
Wire_Label,White,LB-1002,0.25,0.5
Part_Label,White,LB-1003,0.5,1
Sample loom file
The following file is set to import the listed looms into the Cable and Harness Library with the required properties.
//Name,Category,Part Number,Appearance,Wall Thickness,Min Diameter, Max Diameter, Diameter Type
Sleeve_.25-1.25,Wire_Sleeve,WS-1000,Wire Sleeve,0.01,0.25,1.25,Range
Spiral_Wrap_.5-2,Spiral_Wrap,SW-1000,Spiral Wrap,0.01,0.5,2,Range
Corrugated_Tube_1.5,Corrugated_Tube,CT-1000,Corrugated Tube,0.01,,1.5,Fixed
Sample custom (user-define) virtual part file
The following file is set to import the listed custom virtual parts into the Cable and Harness Library with the required properties.
//Name,Category,Part Number
Clip01,Misc,CP-1000
Solder,Misc,SD-1001
Tye_Wrap,Misc,TW-1000
Sample raw ribbon cable file
The following file is set to import the listed custom raw ribbon cables into the Cable and Harness Library with the required properties.
//Name,Category,Part Number,Conductor One Appearance,Ribbon Body Appearance,Number of Conductors,Pitch,Height,Width,Gauge,Core Size
28AWG_10Con,Standard Gray,28AWG_10Con,Red,Gray,10,0.050,0.035,0.500,28,
28AWG_14Con,Standard Gray,28AWG_14Con,Red,Gray,14,0.050,0.035,0.710,28,
28AWG_16Con,Standard Gray,28AWG_10Con,Red,Gray,16,0.050,0.035,0.800,28,