To Show and Edit Violations in a Rigid Route

When you edit rigid piping routes, bent tubing routes, and derived route violations may occur. With the run or route active, use the Show Violations command to identify all violations in a route and then make appropriate changes.

  1. Activate the run or rigid route in error conditions.
  2. In the Model browser, right-click the route and select Show Violations.

    The Show Violations dialog box displays a list of violations on the route.

  3. Click to highlight the corresponding problematic section in the graphics window to identify the violations.
  4. Click OK.
  5. Make appropriate edits, for instance, modify the style criteria, reposition route points and segments, edit dimensions, and add or remove constraints.

    When all violations are corrected, the route node in the Model browser automatically changes to the normal state.

Populating routes and runs use the library fittings and conduit parts in the Content Center so you must configure the Content Center correctly. Otherwise, you may fail to retrieve the library data to update the populated routes. In addition, if geometric constraints or dimensions make the route sketch over-constrained, you cannot continue before fixing the route sketch.

Once the system succeeds to resolve the route edits, violations may still occur. The Model browser hence represents an error icon beside the route. With the run or route active, you can right-click the route and use Show Violations to identify a list of error conditions. For instance: