E5079

E5079 WARNING: E5079 EXCESSIVE ELEMENT INTERNAL LOAD(S) DETECTED
Cause: One or more elements with elastic-plastic material properties developed an excess amount of plastic strain for the load increment size.
Action: None, if the bisect limit has not been reached. The solver will automatically adjust and restart the load increment. If the bisect limit has been reached, increase the number of load increments. See messages E5075 and E5076 above. See also the NLPARM Bulk Data entry in the Autodesk Nastran Reference Guide, Section 4, Bulk Data.
Remarks: None.