CSHEAR

Shear Panel Element Connection

Description: Defines a shear panel element.

Format:

Example:

Field Definition Type Default
EID Element identification number. Integer > 0 Required
PID Identification number of a PSHEAR property entry. Integer > 0 Required
Gi Grid point identification numbers of connection points. Integer > 0, all unique Required

Remarks:

  1. Element identification numbers must be unique with respect to all other element identification numbers.
  2. Grid points G1 through G4 must be ordered consecutively around the perimeter of the element.
  3. All the interior angles must be less than 180°.

Figure 1. CSHEAR Element Connection and Coordinate System

Figure 2. CSHEAR Element Corner Forces and Shear Flows