Flange plates

Use the Flange plates panel to define the geometric dimensions of the plates on flange bars.

Dialog elements

Note: If the connection is not symmetrical the Flange plates panel is divided in two panels:
  • Upper flange plates and Lower flange plates for Beam-to-Beam Splice connections
  • Right flange plates and Left flange plates for Column-to-Column Splice connections

Center
Automatically calculates the distance from the bar edge and the distance from the upper bar edge.
Note: If the connection is symmetrical, this option cannot be deactivated.
Distance from right/lower bar edge
Specify the distance between the plate and the right or lower bar edge.
Note: If Center is selected, or if the connection is symmetrical, this distance is calculated automatically.
Distance from left/upper bar edge
Specify the distance between the plate and the left or upper bar edge.
Note: If Center is selected, or if the connection is symmetrical, this distance is calculated automatically.
Length
Enter the length of the plate.
Width
Enter the width of the plate.
Thickness
Enter the thickness of the plate.
Material
Select the plate material.
Distance from external edge bar flange
Specify the distance between the edges of the internal plate and the bar flange.

Beam-to-Beam Splice connections

Column-to-Column Splice connections