Import a fabrication job (.MAJ) from an Autodesk Fabrication product (CADmep, ESTmep, or CAMduct) into a
Revit model when you want to continue modelling in
Revit. Synchronizing a fabrication job with an existing
Revit model is not supported. The fabrication job must be imported into a
Revit model that does not contain any fabrication parts. (The model can contain generic duct, pipe, architectural, or structural steel elements.) Only fabrication parts that are supported in
Revit can be imported.
- In
Revit, create a new model or open a model that does not contain any fabrication parts. Use the Fabrication Settings tool to select the same configuration that was used to create the model the fabrication job is based on. See
Specify Fabrication Settings.
- Click Insert tabImport panelImport MEP Fabrication Job.
- Select an option for Associate Hangers and click OK.
- No: Imported parts with hangers will not maintain their association in
Revit.
- Fabrication Parts Only: Imported parts with hangers will maintain their association in
Revit.
- Fabrication Part + Structure: Imported parts with hangers and a structure above will maintain their association in
Revit.
- Navigate to and select a .MAJ file and click Open.
In the MEP Fabrication Open Job - Succeeded dialog, you can expand the details to view warnings or which fabrication services were loaded.
- Click OK to continue.
Support for CIDs
The following CIDs are supported when no holes have been added to the item.
- 166 ‐ Canvas Connection
- 501, 507, 514, 535, 969 ‐ Rectangular Dampers
- 509, 533 ‐ Round Dampers
- 518 ‐ Rectangular Heater Battery
- 519 ‐ Rectangular Attenuator
Generally speaking, end of line equipment is not supported. Specifically, this includes the following CIDs.
- 503, 505, 521, 964, 983, 996, 530, 764, 765, 1196 ‐ Terminal/Grille Diffusers ‐ Louvre
- 913 ‐ EOL Fan
- 2189, 2190, 2191, 2192 ‐ Floor Drains
The following inline CIDs are not currently supported.
- 833, 974, 999, 1142 ‐ Standard Parts
- 980 ‐ Inline Pump
- 1049 ‐ Elliptical Reducer
- 1150 ‐ Splitter Damper Blade
- 1198 ‐ Gully Trap
- 2185 ‐ 2 Way Baffle
The following flexible CIDs are not currently supported.
- 838, 873, 2873, 3873, 3108
The following structural CIDs are not currently supported.
The following architectural CIDs are not currently supported.
- 1102, 1106, 1114, 1152, 1157, 1165, 1168, 1169
The following wrapped objects and sub‐assemblies CIDs are not currently supported.