Compare Outlet Flow Rates in the Decision Center

In this step, we use the Critical Values component of the Decision Center to compare outlet flow rates from the two designs.

In the Decision Center, right click on Summary Values, and click Update summary values.

summary values

Note: View the Summary Plane data on the Planes tab of the Decision Center.

critical values

To plot the pressure from the four meshes, click on Pressure, and click the Plot Selected Rows button:

pressure values

pressure plot

Note: Note how the pressure drop steadily decreases with each mesh refinement. The difference between Step 3 and the final mesh is much smaller than between Steps 1 and 2. This clearly shows that the pressure drop is changing less with each mesh refinement, leading toward a mesh-independent solution.

For more about Critical Values

Congratulations! You have completed the exercise. Click here to return to the Tutorials Title Page.