Simulating Smoke Visibility

Because smoke visibility is derived from the flow results computed by Autodesk® CFD, it can be enabled either before running or after the solution is complete.

Basic analysis considerations

Flow

Thermal

On the Solve dialog, enable both Flow and Heat Transfer.

To enable Smoke visibility prior to running an analysis

  1. On the Control tab of the Solve dialog, click the Results quantities button.
  2. Check the Smoke visibility box.
  3. To define the characteristics of the environment, click the Parameters button adjacent to the Smoke visibility check box.

To enable Smoke visibility for a completed analysis

  1. Follow the preceding procedure to enable the Smoke visibility result quantity.
  2. On the Control tab of the Solve dialog, leave the Continue From field at the last iteration.
  3. Set the Iterations to run to be 0, and click Solve.

The analysis will appear to start, but will not solve any additional iterations. The smoke visibility results are then computed and made available for visualization.