To Change Pipe Network Interference Check Conditions or Properties

  1. In Toolspace, on the Prospector tab, expand the Pipe NetworksInterference Checks collection.
  2. Right-click the interference check and click Interference Check Properties.
  3. Change information in the Interference Check Properties dialog box and click Apply to save the changes.
  4. Click OK to accept all changes and rerun the interference check.

    The following prompt is displayed:

    Interference check created.

    Number of interferences found: X

  5. Click OK.