Drawing Format Tab (Project Properties Dialog Box)

Define project default settings for drawings.

Find
 Command entry:  AEPROJECT

All information defined in this tab is saved to the project definition file as drawing defaults used when you start a new drawing.

In the Project Manager, right-click on the project name and select Properties. Select the Drawing Format tab.

Ladder Defaults

Vertical/Horizontal

Specifies whether to create ladders horizontally or vertically.

Spacing

Specifies the spacing between each rung.

Default: insert new ladders without references

Sets the default for the Insert Ladder command. New ladders you insert do not have line reference numbering, by default.

Width

Specifies the width of the ladder.

Multi-wire Spacing

Specifies the spacing between each rung in multi-wire phases.

Format Referencing

Specifies the default referencing system. There are three modes:

X-Y Grid

All referencing is tied to an X-Y grid system of numbers and letters along the left-hand side and top of the drawing. Set the vertical and horizontal index numbers and letters of your drawing, spacing, and origin in the X-Y grid setup dialog box.

Tip:

Use negative spacing values for Horizontal or Vertical to change the origin of the X-Y grid system to be other than the upper left-hand corner of the drawing.

X Zones

Like X-Y Grid, but there is not a Y-axis. Set the horizontal labels, spacing, and origin on the X Zones setup dialog box.

Tip:

Use a negative zone spacing value if you want the zone reference origin to be at the right side of the drawing.

Reference Numbers

Each ladder column has a column of assigned reference numbers.

Setup

Specifies how to display reference numbers -number only, numbers in a hexagon, the sheet and number values, and so on.

Scale

Feature Scale Multiplier

Sets the scale factor used when inserting new components or wire numbers on the drawing. To insert everything 25% bigger than normal, change the edit box value from 1.00 to 1.25. This change does not affect components and wire numbers that are already present on the drawing.

inch/inch scaled to mm/mm full size

Select inch if your drawing is to use library symbols from the JIC1/JIC125 libraries or mm full size for the metric scaled symbol libraries. It adjusts the wire connection trap distance that determines whether closely spaced wire ends connect or not.

Tag/Wire Number/Wire Sequence Order

Sets the default component tag, wire numbering, and wire sequence sort order for the drawing. Your selection overrides the project settings for sort order unless you select No override.

Layers

Defines and manages wire and component layers.

Note: No matter which layer is current, wires always go to a wire layer and components to component layers.