Sets panel footprint drawing defaults, such as footprint insertion scale, balloon setup, and layer assignments.
FindPanel Configuration saves settings as attribute values on a non-visible block named WD_PNLM. In any panel layout command, if this block is not present in the current drawing a message box displays asking permission to insert the block. The location of the block is not critical.
Specifies the number/letter to use as the first item number. AutoCAD Electrical toolset manages item number, drawing-wide, or project-wide (over many drawings), so that the same number is always applied to identical components.
Opens the Panel Component Layers subdialog box for setting the panel component layers, non-text graphic layers, and nameplate layers. Panel footprint layering works in the same way AutoCAD Electrical toolset schematic layering. When AutoCAD Electrical toolset inserts a footprint, it is modified on the fly to match the layering scheme set up in this dialog box.
Specifies the x and y distance spacing for multiple footprint inserts.
Specifies the default insert scale for panel footprint symbols. Also specifies whether to insert the attribute template drawings and the scale to use.
You can set up to have visible attributes added to any footprint automatically at footprint insertion time. Using non-intelligent footprint representations can insert with smart AutoCAD Electrical toolset attributes added automatically, on the fly.
There are five attribute template drawings: |
|
wd_ptag_addattr_comp.dwg |
component footprints |
wd_ptag_addattr_trm.dwg |
terminal footprints |
wd_ptag_addattr_wtrm.dwg |
terminal with wire no. as terminal number |
wd_ptag_addattr_itemballoon.dwg |
balloons |
If the appropriate attribute template exists, the following steps are performed when a panel footprint is inserted.
Uncheck the Enabled check box if you do not want AutoCAD Electrical toolset to search for the attribute template drawing. If enabled, select a scale factor, 1.0 to insert as is, or select to scale to a specific text height.
Specifies the x, y, or z-offset value used in the Panel Wire Connection report. If the footprint symbols carry the X?TERMxx attributes, their XYZ wire connection location is included in the report and offset by these values.
Use the Setup button to define the default wire connection text format used by the Wire Annotation feature.