Devices can have a single connection point or multiple connection points.
To configure the connectors of a device style
Connector Property | Description |
---|---|
Number of poles | The number of poles on the connector: 1, 2, or 3. You can select a number, select By Circuit to retrieve the value from the circuit when it is assigned, or select Undefined. |
Voltage | The voltage on the connector. You can enter a voltage, select from the voltages defined in the drawing that are valid for the currently specified number of poles, select By Circuit to retrieve the value from the circuit when it is assigned, or select Undefined. |
Load Phase 1 Load Phase 2 Load Phase 3 | The load (in VA) on the connector. For each device added, this load is added to the circuit. You can use this to automatically assign a load as you add the device. If the Number of Poles is <Undefined> or 1, only Load Phase 1 is editable. If Number of Poles is 2, then Load Phase 1 and Load Phase 2 are editable. If Number of Poles is 3, then Load Phase 1, Load Phase 2, and Load Phase 3 are editable. |
Load Category | The load category of the connector. You can select from the load category defined in the drawing, or you can select Undefined. |
Load Sub-category | The load sub-category of the connector. You can select Motor. |
Maximum Overcurrent Rating (amps) | Reserved for future use. |
Power Factor | Reserved for future use. |