Dead Loads

0

No rule. Used when a rule in the formula of a combination for a given load type is not defined.

Sum of all dead loads multiplied by the γ s factor (3rd column with factors in the table for definition of nature factors).

Sum of all dead loads multiplied by the γ max factor (1st column with factors in the table for definition of nature factors).

Sum of all dead loads multiplied by the γ min factor (2nd column with factors in the table for definition of nature factors).

Set of sums of all dead loads multiplied by the γ min factor (2nd column with factors in the table for definition of nature factors) or by the γ max factor (1st column with factors in the table for definition of nature factors).

Sum of all dead loads multiplied by the γ a factor (4th column with factors in the table for definition of nature factors).

Set of sums of all dead loads multiplied by the γ min factor (2nd column with factors in the table for definition of nature factors) or by the product of the γ max factor (1st column with factors in the table for definition of nature factors) and the ξ 1 simultaneity factor (13th column with factors in the table for definition of nature factors).

A set of sums of all dead loads multiplied by the ξ 1 simultaneity factor (13th column with factors in the table for definition of nature factors) and by the γ min factor (2nd column with factors in the table for definition of nature factors) or by the γmax factor (1st column with factors in the table for definition of nature factors). The formula is applied in the regulations of Eurocode 2 (Belgian NAD).

A set of sums of all dead loads multiplied by the ξ 1 simultaneity factor (13th column with factors in the table for definition of nature factors) and by the γ s factor. The formula is applied in the regulations of Eurocode 1 for greenhouses.