Required and Provided reinforcement design according to the NF EN 1992-1-1/NA March 2016 edition was implemented.
The implementation includes reinforcement design for Beams, Columns, Foundation, Slabs, and Walls.
The code is set as default in the relevant regional settings. See
RC Code - Eurocode 2 (EN 1992-1-1:2004/A1:2014) and National Annexes
To find these new regional new load combination codes:
- Click Tools Job Preferences Design Codes.
The Job Preferences dialog opens.
- Select Design Codes in the left panel of the Job Preferences dialog.
- Click the RC Structures drop-down list to see the list of available codes.
Note: The codes available in the drop-down lists depend on the country selected in the Preferences dialog. To configure the list of available codes, click the arrow, and then click More at the bottom of the list.