Work with Pipe Controls

When a segment of pipe is selected in a view, several controls let you adjust the size, length, elevation, and slope for pipe segments.

Using dimension controls

  1. Select a pipe in the drawing area to display the pipe controls, and offset values.
  2. Click the temporary length control above a pipe segment, enter the desired length for the pipe, and press Enter.

Using elevation controls

  1. Select a pipe in the drawing area to display the pipe controls, and offset values.
  2. Click the elevation control at each end of a pipe segment, enter a value for the elevation, and press Enter.

    If you enter a different value for each end of a segment, slope is applied to the segment.

Using slope controls

  1. Select a pipe in the drawing area to display the pipe controls, and offset values.
  2. Click the elevation control at one end of the pipe, enter a value for the offset that specifies an elevation that is either higher or lower than the offset at the other end of the pipe and press Enter.

    The slope control at midpoint indicates the direction of the slope and points toward the reference end of the pipe. (When the slope value is changed, the reference end remains at its current elevation.) The value for the slope control at the center of the pipe indicates the rise/run, angle, percentage or ratio for the slope, depending on the Project Units parameter for the Piping discipline in the Project Units dialog.

Toggling the reference end

  1. Click the angle at the midpoint of the pipe.

    The angle flips to point to the opposite end of the pipe.

Setting an absolute slope

  1. Click the value for the slope at the midpoint of the pipe, enter a value for the slope, and press Enter.

    The value that you enter is the rise of the slope for the run or the absolute angle for the slope, depending on the Slope Display parameter in the Project Units dialog.